Abstract This article presents some of the most important developments in the field of digital medicine that have appeared over the last 12 months and are related to cardiovascular medicine. The article consists of three main sections, as follows: (i) artificial intelligence-enabled cardiovascular diagnostic tools, techniques, and methodologies, (ii) big data and prognostic models for cardiovascular risk protection, and (iii) wearable devices in cardiovascular risk assessment, cardiovascular disease prevention, diagnosis, and management. To conclude the article, the authors present a brief further prospective on this new domain, highlighting existing gaps that are specifically related to artificial intelligence technologies, such as explainability, cost-effectiveness, and, of course, the importance of proper regulatory oversight for each clinical implementation.
A Real-world Experience of Atrioventricular Synchronous Pacing with Leadless Ventricular Pacemakers
No container title available | November 16, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available
Aims: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are currently lacking. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. Methods: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous-ventricular pacing (AsVP) ≥70%. Results: Fifty-six percent of patients achieved AsVP ≥70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure and pulmonary hypertension. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were persistent atrial arrhythmias, small A4-wave amplitude, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. Conclusion: With the increasing popularity of leadless PM, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.
Catheter ablation of ventricular tachycardia in patients with postinfarction left ventricular aneurysm
Journal of Cardiovascular Electrophysiology | October 20, 2021 | Volume: 32 | Issue: 12 | Pages: 3156-3164
AbstractBackgroundWhile ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients.MethodsOur study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018.ResultsOf 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end‐diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low‐voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow‐up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all‐cause mortality at 1‐year follow‐up was 94%.ConclusionRadiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.
Artificial intelligence derived age algorithm after heart transplantation
European Heart Journal | October 20, 2021 | Volume: 42 | Issue: Supplement_1 | Pages: No page available
Abstract Background An artificial intelligence (AI) algorithm detecting age from 12-lead ECG has been suggested to signal “physiological age” of the individual. Importantly, increased physiological age gauged by an increased difference between ECG-age and chronological age has been associated with higher risk of cardiac events in non-transplant population. Purpose We sought to investigate the validity of the AI-derived ECG-age algorithm in patients who underwent heart transplantation and its relationship to major adverse cardiovascular events (MACE). Methods A total of 489 consecutive patients who had undergone heart transplantation in our institution between 1994 and 2018 were studied. AI-ECG age was calculated by a previously-trained artificial intelligence (AI) algorithm using a 12-lead ECG per patient. ECGs used in the training process of the algorithm were excluded. The average of the ECG-ages within one year before and one year after heart transplantation was used to represent pre- and post-transplant ECG-ages. MACE was defined as any incidence of revascularization, re-transplantation, and death. Results Pre-transplant ECG-age (mean 63±10 years) correlated significantly with recipient chronological age (mean 50±13 years, r=0.57, p<0.0001), but this correlation between recipient and ECG-ages was weakened after transplantation (mean post-transplant ECG age of 55±10 years, r=0.34, p<0.0001). Interestingly, post-transplant ECG-age correlated significantly with donor age (mean ECG age of 55±10 years vs. mean donor age of 32±13 years, r=0.42, p<0.0001). During a median (IQR) follow-up of 9 (5, 14) years, 251 patients had MACE. Mean change in ECG age after transplantation compared to before was −8.8±12.7 years. Patients who had an increase in ECG-age after compared to before transplantation showed increased risk of MACE (HR: 1.53 [1.16, 2.01], p=0.002), independent of recipient and donor ages (adjusted HR: 1.68 [1.26, 2.25], p=0.001); whereas there were no significant differences in risk of MACE in patients who were transplanted with an older donor heart (HR: 1.07 [0.77, 1.50], p=0.66). In a Kaplan Meier survival analysis, those with increased ECG-age after transplantation had significantly lower MACE-free survival compared to those with decreased ECG-age. (Log-rank P=0.002; Wilcoxon P=0.001) (Figure) Conclusion Post-transplant ECG-age correlates more faithfully with the donor's than the recipient's chronological age, suggesting that ECG-age more closely reflects cardiac age than the patient age. Furthermore, ECG-age derived cardiac aging after transplantation is associated with higher risk of MACE. Funding Acknowledgement Type of funding sources: None.
Machine learning aids clinical decision making in patients presenting with angina and non-obstructive coronary artery disease
European Heart Journal | October 20, 2021 | Volume: 42 | Issue: Supplement_1 | Pages: No page available
Abstract Background Coronary microvascular dysfunction (CMD) is associated with an increased risk of cardiovascular morbidity and mortality. The current gold-standard comprehensive assessment of CMD is through a limited-access invasive catheterization lab procedure. Purposes We aimed to develop a point-of-care tool to assist clinical guidance in patients presenting with chest pain and/or an abnormal functional stress test and with non-obstructive coronary artery disease (NOCAD) based on demographic data and resting ECG waveforms. Methods This study included 1,893 NOCAD patients (<50% angiographic stenosis) who underwent CMD evaluation as well as a standard ECG up to 1 year prior. Microvascular endothelial-independent dysfunction was defined by abnormal coronary flow reserve (CFR) <2.5 in response to intracoronary adenosine administration. Microvascular endothelial dysfunction was defined by a maximal percent increase in coronary blood flow (%ΔCBF) ≤50% in response to intracoronary acetylcholine infusion. We trained algorithms to distinguish between the following outcomes: CFR ≤2.5, ΔCBF (%) ≤50, and the combination of both. Two classes of algorithms were trained, one depending on ECG waveforms as input, and another using tabular style clinical data. The optimal classification threshold was determined by maximizing Youden's J. Results Mean age was 51±12 years and 66% were females (n=1,257). AUC values ranged from 0.49 to 0.67 for all the outcomes. The best performance in our analysis was for the outcome CFR ≤2.5 via logistic regression on tabular variables. AUC and accuracy were 0.67 and 60%; while sensitivity and NPV were 70% and 85%. Specificity and PPV were 56% and 0.35%. When decreasing the threshold from the “optimal” one (24%) to 15%, sensitivity and NPV increased to 92% and 90% respectively, while specificity and PPV decreased to 25% and 29% respectively (Figure 2). Conclusion An AI-enabled algorithm may be able to assist clinical guidance by ruling out CMD in patients presenting with chest pain and/or an abnormal functional stress test. This algorithm needs to be prospectively validated in different cohorts. Funding Acknowledgement Type of funding sources: Private grant(s) and/or Sponsorship. Main funding source(s): The James Nutter Family & Maria Long Family Fellowship in Cardiovascular Research and Mayo Clinic Figure 1Figure 2
Detecting cardiomyopathies in pregnancy and the postpartum period using ECG
European Heart Journal | October 20, 2021 | Volume: 42 | Issue: Supplement_1 | Pages: No page available
Abstract Background Cardiovascular disease (CVD) has been identified as a major threat to maternal health in the US and UK with cardiomyopathy being one of the most common acquired CVD in the pregnant and postpartum period. Diagnosing cardiomyopathy in pregnancy is challenging due to an overlap of cardiovascular symptoms with normal pregnancy symptoms. Purpose The purpose of this study was to evaluate the effectiveness of an ECG based deep learning model in identifying cardiomyopathy among pregnant and postpartum women. Methods We utilized an ECG based deep learning model to detect cardiomyopathy in a cohort of pregnant or postpartum women seen at multiple hospital sites. Model performance was evaluated using area under the curve (AUC), accuracy, sensitivity, and specificity. We compared the diagnostic probabilities of the deep learning model with natriuretic peptides and a multivariable model consisting of demographic and clinical parameters. Results 1,807 women were included. 7%, 10% and 13% had LVEF ≤35%, <45% and <50% respectively. The ECG based deep learning model identified cardiomyopathy with an AUC of 0.92 for left ventricular ejection fraction (LVEF) ≤35%, 0.89 for LVEF <45% and 0.87 for LVEF <50%. For LVEF ≤35%, AUC was higher in Black (0.95) and Hispanic (0.98) women compared to white (0.91). Natriuretic peptides and the multivariable model had AUCs of 0.85 and 0.72 respectively. Conclusions A deep learning model effectively identifies cardiomyopathy in pregnant or postpartum women, outperforms natriuretic peptides and traditional clinical parameters with the potential to become a powerful initial screening tool for cardiomyopathy in the obstetric care setting. Funding Acknowledgement Type of funding sources: Other. Main funding source(s): This study was made possible using resources supported by the Mayo Clinic Women's Health Research Center and the Mayo Clinic Building Interdisciplinary Research Careers in Women's Health (BIRCWH) Program funded by the National Institutes of Health (NIH), grant number K12 HD065987. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Generalizability of the EAST-AFNET 4 trial: assessing outcomes of early rhythm-control therapy in patients with atrial fibrillation
European Heart Journal | October 20, 2021 | Volume: 42 | Issue: Supplement_1 | Pages: No page available
Abstract Background The Early Treatment of Atrial Fibrillation for Stroke Prevention Trial (EAST-AFNET 4) demonstrated clinical benefit of early rhythm-control therapy in patients with recently diagnosed atrial fibrillation (AF) and concomitant cardiovascular conditions (CHA2DS2-VASc-Score ≥2) compared to the current practice of limited rhythm-control therapy to improve AF-related symptoms. Purpose To evaluate the generalizability of the EAST-AFNET 4 trial in routine practice, we assessed the proportion of patients who would have met trial eligibility and examined the association between early rhythm-control and clinical outcomes. Methods Using a large US administrative database, we identified 109,739 patients with newly diagnosed AF from July 28th, 2011 to December 30th, 2016, the enrollment period of the EAST-AFNET 4 trial. Eligibility for trial inclusion was assessed based on inclusion criteria. Eligible patients were classified as either receiving early rhythm-control, i.e AF ablation and/or any antiarrhythmic drug therapy, within the first year after AF diagnosis (N=27,106) or patients not receiving early rhythm-control (N=82,633). The date 12 months after the first AF diagnosis was defined as the index date and the start of the follow up period. Propensity score overlap weighting was used to balance patients on 90 baseline characteristics. Cox proportional hazards regression was used to compare early rhythm-control with no early rhythm-control for the primary outcome of a composite end point of all-cause mortality, stroke, or hospitalization with the diagnoses heart failure or myocardial infarction. Results Eligible for the trial were 72.9% (82,633/109,739) of all patients with newly diagnosed AF. Early rhythm-control therapy was associated with a reduction in the composite end point in the overall cohort of patients (hazard ratio [HR] 0.85; 95% confidence interval [CI] 0.75–0.97; P=0.015) with largely consistent treatment effects between patients eligible or ineligible for the trial. The reduction of stroke risk associated with early rhythm-control therapy was found in the overall cohort (HR 0.66; 95% CI 0.47–0.93; P=0.017) and in the trial-eligible cohort (HR 0.67; 95% CI 0.45–0.98; P=0.041). Conclusion In a large health care data set, the majority of patients with newly diagnosed AF were eligible for the trial. Early rhythm-control therapy was associated with a 15% reduction in the composite end point of all-cause mortality, stroke, or hospitalization with the diagnoses heart failure or myocardial infarction, with the greatest benefit in the reduction of stroke risk. The treatment effect was consistent between patients eligible or ineligible for the trial. Patients in routine practice had higher rates of adverse outcomes than the trial, but the relative risk reduction with early rhythm-control therapy was similar. These data demonstrate the potential of early rhythm-control therapy to reduce outcomes in patients with AF. Funding Acknowledgement Type of funding sources: Foundation. Main funding source(s): German Heart Foundation (Mit Fördermitteln der Deutschen Herzstiftung e.V.)
Subcutaneous ICD combined with VT ablation for the secondary prevention of sudden cardiac death: pilot data from the prospective multinational SICD-VTAbl study
European Heart Journal | October 20, 2021 | Volume: 42 | Issue: Supplement_1 | Pages: No page available
Abstract Background The aim of the Subcutaneous ICD Combined with Ventricular Tachycardia Ablation (SICD-VTAbl) Study is to provide preliminary data on the safety and efficacy of a management strategy that incorporates S-ICD implantation and VT ablation among patients with a secondary prevention indication for an ICD. We hypothesize that VT ablation for the prevention of monomorphic VT recurrence combined with S-ICD implantation for termination of life-threatening VT/VF is safe, while reducing the need for device interventions and systemic complications associated with conventional transvenous ICD implantation for secondary prevention. Methods SICD-VTAbl is an uncontrolled, prospective, multinational observational study, conducted in France, Germany, US (Rochester NY, and Rochester MN) and coordinated in Israel. We aim to prospectively enroll 30 patients presenting with scar-related VT/VF who will undergo VT ablation/substrate modification followed by S-ICD implantation. The primary endpoint is the first occurrence of S-ICD therapy (appropriate and inappropriate). Secondary endpoints include separate occurrence of appropriate and inappropriate ICD therapies, peri-procedural complications, and adverse clinical outcomes. Results We provide clinical, arrhythmia, and outcome data on the first 15 patients enrolled in the SICD-VTAbl Study through February 2021. Mean age was 59±12 years, 78% were males, 60% had New York Heart Association (NYHA) Class ≥II symptoms, 20% had renal insufficiency, and 33% were treated with an antiarrhythmic medication (all amiodarone). Periprocedural, arrhythmia, and long-term outcome data are provided in Table 1. There were no major complications associated with the VT ablation and the S-ICD implantation procedures. During a median follow-up of 6 months (interquartile range: 2–12 months), 2 patients (13%) received S-ICD therapy: one patient (7%) experienced VF terminated by the S-ICD and one patient experienced a single episode of inappropriate S-ICD therapy. Adverse events during follow-up, unrelated to study procedures, occurred in 3 patients (20%): hospitalization for heart failure exacerbation (N=1) and non-cardiovascular hospitalizations (N=2). None of the patients died during follow-up (Table 1). Conclusions Our preliminary data from the SICD-VTAbl Study suggest that a management approach that incorporates VT ablation followed by S-ICD implantation is safe and may lead to improved arrhythmia and clinical outcomes in patients presenting with a secondary prevention indication for an ICD. Funding Acknowledgement Type of funding sources: Other. Main funding source(s): Research grant to Sheba Medical Center from Boston Scientific
Machine learning aids clinical decision-making in patients presenting with angina and non-obstructive coronary artery disease
European Heart Journal - Digital Health | October 18, 2021 | Volume: 2 | Issue: 4 | Pages: 597-605
Abstract Aims The current gold standard comprehensive assessment of coronary microvascular dysfunction (CMD) is through a limited-access invasive catheterization lab procedure. We aimed to develop a point-of-care tool to assist clinical guidance in patients presenting with chest pain and/or an abnormal cardiac functional stress test and with non-obstructive coronary artery disease (NOCAD). Methods and results This study included 1893 NOCAD patients (<50% angiographic stenosis) who underwent CMD evaluation as well as an electrocardiogram (ECG) up to 1-year prior. Endothelial-independent CMD was defined by coronary flow reserve (CFR) ≤2.5 in response to intracoronary adenosine. Endothelial-dependent CMD was defined by a maximal percent increase in coronary blood flow (%ΔCBF) ≤50% in response to intracoronary acetylcholine infusion. We trained algorithms to distinguish between the following outcomes: CFR ≤2.5, %ΔCBF ≤50, and the combination of both. Two classes of algorithms were trained, one depending on ECG waveforms as input, and another using tabular clinical data. Mean age was 51 ± 12 years and 66% were females (n = 1257). Area under the curve values ranged from 0.49 to 0.67 for all the outcomes. The best performance in our analysis was for the outcome CFR ≤2.5 with clinical variables. Area under the curve and accuracy were 0.67% and 60%. When decreasing the threshold of positivity, sensitivity and negative predictive value increased to 92% and 90%, respectively, while specificity and positive predictive value decreased to 25% and 29%, respectively. Conclusion An artificial intelligence-enabled algorithm may be able to assist clinical guidance by ruling out CMD in patients presenting with chest pain and/or an abnormal functional stress test. This algorithm needs to be prospectively validated in different cohorts.
Radial strain imaging-guided lead placement for improving response to cardiac resynchronization therapy in patients with ischaemic cardiomyopathy: the Raise CRT trial
EP Europace | September 30, 2021 | Volume: 24 | Issue: 5 | Pages: 835-844
Abstract Aims To evaluate the benefit of speckle tracking radial strain imaging (STRSI)-guided left ventricular (LV) lead (LVL) positioning in cardiac resynchronization therapy (CRT) in patients (pts) with ischaemic cardiomyopathy with CRT indication. Methods and results We conducted a prospective randomized controlled trial. Patients were enrolled in nine centres with 2:1 randomization into two groups (guided vs. control). Patients underwent STRSI to identify the optimal LV position from six LV segments at midventricular level. Implantation via STRSI was attempted for recommended segment in the guided group only. Follow-up included echocardiography (6 months) and clinical evaluation (6 and 12 months). The primary endpoint was comparison % reduction in LV end-systolic volume at 6 months with baseline. Secondary endpoints included hospitalizations for heart failure and death, and improvement in additional echocardiographic measurements and quality of life score. A total of 172 patients (115 guided vs. 57 control) were enrolled. In the guided group, 60% of the implanted LV leads were adjudicated to be successfully located at the recommended segment, whereas in the control group 44% reached the best STRSI determined segment. There was no difference between the groups in any of the primary or secondary endpoints at 6 and 12 months. Conclusion Our findings suggest that echo-guided implantation of an LV lead using STRSI does not improve the clinical or echocardiographic response compared with conventional implantation.