Citations 179

Reduction in Right Atrial Pressures Is Associated With Hemodynamic Improvements After Transcatheter Edge-to-Edge Repair of the Tricuspid Valve

Circulation: Cardiovascular Interventions | November 24, 2021 | Volume: 14 | Issue: 12 | Pages: No page available

10.1161/circinterventions.121.010557 | PMID 34814697

Background: Investigational transcatheter edge-to-edge repair (TEER) for severe tricuspid regurgitation (TR) has shown promise as an alternative to surgery, but factors influencing outcomes, optimal patient selection, and procedural timing remain incompletely defined. Given the limitations of determining TR severity by conventional echocardiography, our objectives were to determine whether invasive right atrial (RA) pressures performed during the procedure are related to patient outcomes. Methods: This study was a retrospective review of patients who underwent off-label tricuspid TEER using MitraClip (Abbott Vascular, Menlo Park, CA) for significant TR at a single institution. Intraprocedural mean RA pressure, RA peak V-wave, RA pressure nadir, and systolic increase in RA pressure (XV height) were recorded. Results: Thirty-eight patients underwent tricuspid TEER; 33 underwent concomitant mitral TEER for mitral regurgitation. The study cohort was 39% female with a mean age of 78.6±14.3 years. Median follow-up was 339 days (interquartile range, 100–601). Any reduction in mean RA pressure, RA peak V-wave, RA nadir, and XV height occurred in 74%, 82%, 45%, and 87% of patients, respectively. At 1 year, event-free survival was 47%. Postprocedure XV height correlated with TR severity as determined by echocardiography ( P <0.0001). The highest quartile of postprocedure XV height (>8 mm Hg) had worse event-free survival compared with those who had concluding XV height ≤8 mm Hg ( P =0.02). Attainment of a concluding XV height less than or equal to median value was associated with a lower creatinine the next day (1.27±0.47 versus 1.64±0.47 mg/dL, P =0.04). Conclusions: Intraprocedural XV height correlates with TR severity after tricuspid TEER, and lower concluding pressures are associated with improved outcomes. Analysis of RA pressures may serve as a complementary tool for the evaluation of disease severity and procedural guidance.
Mild aortic valve disease and the diastolic pressure–volume relationship in heart failure with preserved ejection fraction

Open Heart | October 20, 2021 | Volume: 8 | Issue: 2 | Pages: e001701

10.1136/openhrt-2021-001701 | PMID 34670831

Objective Mild aortic valve stenosis (AS) and aortic valve (AV) sclerosis are associated with diastolic dysfunction and increased mortality in the general population. This study specifically investigated the impact of mild AV disease in heart failure with preserved ejection fraction (HFpEF). Methods Consecutive patients hospitalised with HFpEF (n=370) underwent assessment of cardiac structure and function and long-term clinical follow-up. Results In the study cohort, 111 had mild AS (30%), 104 AV sclerosis (28%) and 155 a non-calcified AV (42%). Mild-to-moderate AV regurgitation (AR) was present in 64 (17%). Compared with patients with a normal AV, those with AV disease were older, with worse renal function and more atrial fibrillation. E/e′ increased from non-calcified AV to AV sclerosis to mild AS (13.8 (10.8–16.8) vs 15.0 (10.9–20.0) vs 18.0 (12.7–23.3), respectively; p<0.001)). Left ventricular diastolic pressure–volume relationships were shifted leftwards in patients with AS and AV sclerosis, but not influenced by AR. The left ventricular end-diastolic volume normalised at 20 mm Hg was 117±34 mL, 106±30 mL and 112±30 mL in non-calcified AV, AV sclerosis and mild AS, respectively (p=0.023), while 112±32 mL in mild-to-moderate AR. Over 30 months (IQR, 8–61 months), 247 patients died (67%). The presence of mild AV disease was associated with increased mortality, but this was no longer significant after adjusting for age and sex. Conclusions Low-grade AV disease is common among patients hospitalised for HFpEF and is associated with older age, atrial arrhythmia, renal dysfunction, higher left heart filling pressures and increased left ventricular chamber stiffness.
Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement in Severe Mitral Annular Calcification: An Analysis of the Transcatheter Mitral Valve Replacement in Mitral Annular Calcification Global Registry

Circulation: Cardiovascular Interventions | October 19, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circinterventions.121.010854 | PMID 34665654

Background: Several studies have evaluated preprocedural imaging predictors of left ventricular outflow tract obstruction (LVOTO) after transcatheter mitral valve replacement. The patient cohorts in these studies were heterogeneous and included patients with transcatheter mitral valve replacement in failed bioprostheses, annuloplasty rings, and severe mitral annular calcification (MAC). The goal of this study was to evaluate predictors of LVOTO specific to patients undergoing valve-in-MAC. Methods: This study included patients with severe MAC who underwent valve-in-MAC and had optimal quality preprocedural multidetector row computed tomography scans eligible for retrospective analysis. Baseline demographic, echocardiographic, and procedural data on these patients were collected. multidetector row computed tomography parameters were analyzed for association with LVOTO, defined as increase in mean LVOT gradient by ≥10 mm Hg with accompanying hemodynamic instability. Results: Seventy-one patients with optimal preprocedural computed tomography scans were included in this study (mean age, 72.5±13.5 years), 9 of which developed LVOTO (all female). Baseline mean LVOT area, neo-LVOT area (145.3 versus 270.9 mm 2 ; P =0.006), indexed neo-LVOT area (90.1 versus 157.4; P =0.05), and virtual transcatheter heart valve to septum distance (3.1 versus 6.9 mm; P =0.002) were lower in the LVOTO group. Expected % LVOT area reduction was higher in the latter group (58.3 versus 42.7%; P =0.008). In the univariable analysis, the baseline mean LVOT area, neo-LVOT area, indexed neo-LVOT area, and valve to septum distance were all significantly associated with LVOTO. Conclusions: The systolic mean LVOT area, neo-LVOT area, indexed neo-LVOT, expected percentage LVOT area reduction, and the valve to septum distance were associated with LVOTO after valve-in-MAC.
Utility of Intracardiac Echocardiography in the Early Experience of Transcatheter Edge to Edge Tricuspid Valve Repair

Circulation: Cardiovascular Interventions | September 3, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circinterventions.121.011118 | PMID 34474586

Background: Tricuspid edge to edge repair (TEER) is a novel treatment for severe tricuspid regurgitation and is highly dependent on intraprocedural image quality. To date, transesophageal echocardiography (TEE) has been the primary imaging modality used to guide TEER. The role of intracardiac echocardiography (ICE) has not been assessed. The objective of this study was to describe the use and role of 2-dimensional ICE in the early experience of TEER. Methods: Consecutive patients undergoing TEER (with or without concomitant mitral repair) with off-label use of MitraClip (Abbott, Santa Clara, CA) were included in the study. Utilization of 2-dimensional ICE in comparison with TEE imaging were collected in each procedure through retrospective review of the procedural reports and images. Results: Of 42 TEER cases, ICE was used in 15 (36%) and concomitant mitral repair was performed in 37 (86%). ICE was increasingly used over time for TEER. ICE was able to visualize the tricuspid leaflets with high resolution and provided superior leaflet visualization to TEE in 40% of cases where it was used. Patients treated with ICE guidance tended to have a greater baseline severity of tricuspid regurgitation compared with patients treated with TEE guidance alone (8/15 [53%] massive or greater tricuspid regurgitation versus 6/27 [22%]; P =0.09). Degree of tricuspid regurgitation reduction was similar with TEE alone versus ICE plus TEE guidance (1.9±1.0 versus 2.1±1.1 grade reduction, P =0.28). Conclusions: ICE was increasingly used in the early experience of TEER over time. ICE facilitates leaflet visualization for grasping and is a useful adjunct to TEE during TEER.
Effect of eliminating pre‐discharge transthoracic echocardiogram on outcomes after TAVR

Catheterization and Cardiovascular Interventions | August 13, 2021 | Volume: 99 | Issue: 3 | Pages: 861-866

10.1002/ccd.29929 | PMID 34388299

AbstractObjectivesThe aim of this study was to determine the safety of eliminating the pre‐discharge transthoracic echocardiogram (TTE) on 30‐day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR).BackgroundTTE is utilized before, during, and after TAVR. Post‐procedural, pre‐discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR.MethodsPatients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre‐discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post‐TAVR.ResultsA total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre‐discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre‐discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre‐discharge TTE group and none in the group without pre‐discharge TTE at 30‐day follow‐up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre‐discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71).ConclusionsElimination of the pre‐discharge TTE is safe and associated with comparable 30‐day outcomes to routine pre‐discharge TTE. These findings have implication for TAVR practice cost‐efficiency and health care utilization.
Clinical predictors and impact of postoperative mean gradient on outcome after transcatheter edge‐to‐edge mitral valve repair

Catheterization and Cardiovascular Interventions | July 10, 2021 | Volume: 98 | Issue: 6 | Pages: No page available

10.1002/ccd.29867 | PMID 34245208

AbstractBackgroundThe predictors and clinical significance of increased Doppler‐derived mean diastolic gradient (MG) following transcatheter edge‐to‐edge mitral valve repair (MVTEER) remain controversial.ObjectiveWe sought to examine baseline correlates of Doppler‐derived increased MG post‐MVTEER and its impact on intermediate‐term outcomes.MethodsPatients undergoing MVTEER were analyzed retrospectively. Post‐MVTEER increased MG was defined as >5 mmHg or aborted clip implantation due to increased MG intraprocedurally. Baseline MG and 3D‐guided mitral valve area (MVA) by planimetry were retrospectively available in 233 and 109 patients.Results243 patients were included; 62 (26%) had MG > 5 mmHg post‐MVTEER or aborted clip insertion, including 7 (11%) that had aborted clip implantation. Mortality occurred in 63 (26%) during a median follow up of 516 days (IQR 211, 1021). Increased post‐MVTEER MG occurred more frequently in females (44% vs. 16%, p < 0.001), those with baseline MVA <4.0 cm2 (71% vs. 16%), baseline MG ≥4 mmHg (61% vs. 20%), or multiple clips implanted (33% vs. 21%, p = 0.04). Increased post‐MVTEER MG was associated with increased subsequent mortality compared to those with normal gradient (HR 1.91 95% CI 1.15–3.18 p = 0.016) as was aborted clip insertion compared to all others (HR 5.23 95% CI 2.06–13.28 p < 0.001).ConclusionsSmaller baseline MVA and increased baseline MG are associated with increased MG post‐MVTEER and patients with a Doppler‐derived post‐MVTEER MG >5 mmHg suffered excess subsequent mortality. In high risk patients considered for MVTEER, identification of those at risk of iatrogenic mitral stenosis with MVTEER is important as they may be optimally treated with alternate surgical or transcatheter therapies.
Abstract 14140: The Weight of the Evidence: Comparison of Operatively Excised Aortic Valve Weights in Patients With High Gradient versus Low Gradient Aortic Stenosis and Overall Survival Following Aortic Valve Replacement

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.14140

Introduction: Excised aortic valve weight (AVW) correlates with severity of AS. There is some debate about the true severity of AS in low gradient AS (LGAS) compared to high gradient AS (HGAS). We sought to compare patient characteristics and operatively excised AVW in patients with LGAS vs HGAS vs moderate AS. Methods: 916 patients with EF ≥50% undergoing surgical aortic valve replacement for AS between 2010-2012 were included. Clinical and echocardiographic characteristics of LGAS patients (AVA≤1cm 2 , MnG<40mmHg; N=68) were compared to HGAS patients (AVA≤1cm 2 , MnG≥40mmHg; N=745) and operatively excised AVW were compared to moderate AS (AVA>1cm 2 , MnG<40mmHg; N=102). Results: Compared to HGAS, LGAS patients were older (mean age 77 ± 10 vs 73 ± 10 years; p=0.001), often female (56% vs 38%; p=0.006), but without differences in diabetes (26% vs 29%; p=0.78), hyperlipidemia (85% vs 86%, p=0.86), coronary artery disease (49% vs 44%; p=0.53), or hypertension (81% vs 76%; p=0.38). LGAS patients predominantly had trileaflet aortic valves (91% vs 71%; p<0.001), smaller LVOT diameter (2.16 ± 0.15 vs 2.25 ± 0.20 cm; p=0.002), lower stroke volume index (42.1 ± 7.3 vs 49.0 ± 8.8 cc/m 2 ; p<0.001), lower systemic compliance (0.77 ± 0.30 vs 0.93 ± 0.33 ; p<0.001), but no difference in valvulo-arterial impedance (3.96 ± 0.76 vs. 3.84 ± 0.80, p=0.24) compared to HGAS. Excised AVW were lower in patients with LGAS vs HGAS (1.77 ± 0.76 vs 2.69 ± 1.26 g, p<0.001), but not different from moderate AS (1.77 ± 0.76 vs 2.04 ± 0.94 g; p=0.1). This relationship held true when AVW was indexed to body surface area. Three-year mortality post-valve replacement was significantly higher in LGAS compared to HGAS (22% vs 11%, p=0.02). Conclusions: LGAS occurs mostly in older female patients with trileaflet aortic valves. Excised AVW in LGAS is similar to moderate AS but lower than HGAS. However, systemic compliance is higher in LGAS vs HGAS contributing to increased afterload. Poorer outcomes after surgery in LGAS patients may be attributed to noncompliant vasculature which is not corrected with valve replacement and evaluation of patients with LGAS should include assessment of peripheral resistance.
Abstract 15742: Predicting Outcomes After Percutaneous Mitral Balloon Valvotomy: The Impact of Left Ventricular Strain Imaging

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.15742

Introduction: Presence of subclinical left ventricle (LV) dysfunction may influence outcomes after percutaneous mitral balloon valvotomy (PMBV), but cannot be detected by conventional echocardiography. Hypothesis: Preprocedure LV global longitudinal strain (GLS) by speckle tracking TTE detects subclinical LV dysfunction and predicts long-term outcome after successful PMVB. Methods: Consecutive patients undergoing PMBV between 2003-2011 who had comprehensive baseline TTE were included. Patients with suboptimal immediate results (repeat PMBV or mitral surgery within first 6 months) and those with suboptimal TTE strain were excluded. LV strain was analyzed with commercial software (Syngo VVI), and GLS averaged from 18 segments. The primary end point was all-cause mortality. Secondary end point was the composite of death and mitral valve reintervention. Results: Of 110 patients screened, 29 (26%) had unsuitable strain imaging, and 8 (7%) had poor immediate results, leaving 73 in the final cohort. Median follow-up was 3.7 years (interquartile range 1.3-7.2). There were 10 deaths (14%) and 25 late mitral valve interventions (34%). Univariate predictors of death were GLS, age, EF, stroke volume, pulmonary artery pressure, mitral valve area and coronary artery disease. In a multivariate Cox model, GLS was the strongest predictor of death after adjustment for age [HR=1.40 (1.09-1.84), P=0.008]. For the composite endpoint, GLS, mitral valve gradient, and invasively mean left atrial pressure were univariate predictors of death or reintervention. At multivariate analysis, GLS was the sole predictor of events [HR=1.17 (1.01-1.34), P=0.03]. Event-free survival is shown in figure. Intra and inter observer intra-class correlation for strain analysis was 0.87 (0.66-0.96) and 0.84 (0.53-0.95), respectively. Conclusions: GLS is a powerful predictor of long-term outcome after PMVB and appears to have an incremental prognostic value over traditional parameters.
Abstract 12459: Is Ejection Fraction

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.12459

Introduction: In asymptomatic patients with severe aortic stenosis (SAS), left ventricular (LV) ejection fraction (EF) <50% is generally considered to be the threshold for referral for aortic valve replacement (AVR). Hypothesis: We investigated the importance of LVEF on long-term outcome after AVR in symptomatic and asymptomatic SAS patients and studied whether LVEF < 50% is the optimal threshold for referral for AVR. Methods and Results: We retrospectively identified 2017 patients with SAS (aortic valve area (AVA)<1cm2, mean aortic valve gradient ≥40 mm Hg, or indexed AVA <0.6 cm2/m2) who underwent surgical AVR from January 1995 to June 2009 at our institution. Patients were divided into 4 groups depending on preoperative LVEF (<50% in 300 (15%) patients, 50-59% in 331 (17%), 60-69% in 908 (45%), and ≥70% in 478 (24%)). The primary end-point was all-cause mortality. During follow-up of 5.3±4.4 years, 1056 (52%) died. Five-year mortality rate increased with decreasing LVEF (41% (n=106), LVEF<50%); 35% (n=98), LVEF 50-59%; 26% (n=192), LVEF 60-69%; 22% (n=90), LVEF≥70%, p<0.0001). Compared to patients with LVEF≥60%, patients with LVEF 50-59% had increased mortality (HR 1.58, p<0.001), with a similar risk increase in both symptomatic (HR=1.56, p<0.001) and asymptomatic patients (HR 1.58, p=0.006, Figure). In a Cox regression analysis corrected for standard risk factors, LV mass index, AVA, and stroke volume index, LVEF was predictive of all-cause mortality (HR=0.89 per 10%, p<0.001). When this multivariable analysis was repeated in the subset of 1333 patients with no history of coronary artery disease, LVEF was still associated with all-cause mortality (HR=0.90 per 10%, p=0.009). Conclusion: In patients with SAS undergoing AVR, patients with LVEF 50-59% have also increased mortality compared to patients with LVEF>60%, suggesting that a different LVEF threshold should be used when referring for AVR.
Transcatheter Tricuspid Valve Intervention: Current Perspective

US Cardiology Review | July 2, 2021 | Volume: 15 | Issue: No issue available | Pages: No page available

10.15420/usc.2020.26 | PMID 39720492

Tricuspid regurgitation (TR) adversely impacts both quality of life and long-term survival, which generates interest in therapeutic approaches to mitigate these effects. Historically, therapeutic options for TR were limited to surgical approaches, which are often complicated by significant morbidity and mortality in elderly patients with multiple comorbidities. This gap in therapeutic options led to the rapid evolution of transcatheter tricuspid valve intervention (TTVI), with a wide variety of approaches pursued and early results suggesting that TTVI improves clinical outcomes. Numerous strategies, including edge-to-edge repair, annular reduction, spacers, caval valve implantation, and transcatheter tricuspid valve replacement form the basis of TTVI today. In this review, the authors discuss the current state of each approach.