Citations 179

A novel technique—Prophylactic septal radiofrequency ablation to prevent left ventricular outflow tract obstruction with transcatheter mitral valve replacement (RADIO‐TMVR)

Journal of Cardiovascular Electrophysiology | August 21, 2020 | Volume: 31 | Issue: 11 | Pages: 3048-3055

10.1111/jce.14720 | PMID 32820547

AbstractTranscatheter mitral valve replacement (TMVR) with off‐label use of aortic balloon‐expandable transcatheter heart valves has emerged as a therapeutic option in high‐surgical risk patients with severe mitral annular calcification. Left ventricular outflow tract (LVOT) obstruction post valve deployment is a major limitation. We describe a case of septal reduction therapy using radiofrequency ablation (RFA) when established methods of septal reduction were either ineffective or not feasible. RFA permitted successful enlargement of the LVOT area and subsequent TMVR.
Transient Complete Heart Block After Alcohol Septal Ablation

Circulation: Cardiovascular Interventions | August 6, 2020 | Volume: 13 | Issue: 8 | Pages: No page available

10.1161/circinterventions.120.009202 | PMID 32757660

Outcomes of Ambulatory Heart Failure Patients Managed With an Intra-aortic Balloon Pump Before Left Ventricular Assist Device Implantation

ASAIO Journal | August 6, 2020 | Volume: 67 | Issue: 4 | Pages: 430-435

10.1097/mat.0000000000001249 | PMID 33769998

Patients are admitted to the hospital for hemodynamic optimization before left ventricular assist device (LVAD) implantation. The aim of this study was to evaluate the clinical outcomes of hemodynamic optimization using an intra-aortic balloon pump (IABP) in ambulatory heart failure patients before LVAD placement. This retrospective single-center study included 199 noninotrope-dependent patients who underwent durable LVAD implantation between January 1, 2007 and April 10, 2017. Invasive hemodynamic as well as the primary composite end-point of stage 2 or 3 acute kidney injury, right ventricular failure, and 30-day mortality were compared between patients with and without an IABP. Median age was 64 (interquartile range [IQR], 57–71) years and 165 (82.9%) were male; 72 (36.2%) received an IABP. Patients treated with an IABP had worse baseline exercise capacity and hemodynamic parameters. Patients with an IABP had greater relative reduction in pulmonary artery mean pressure (−16% vs. −2%; p ≤ 0.001). The primary composite end-point was not different between patients who had an IABP and those who did not (20.8% vs. 20.5%; p = 0.952), as were each of the individual end-points. Despite worse baseline hemodynamic parameters and exercise capacity, ambulatory heart failure patients who received an IABP before LVAD implantation had more favorable reductions in pulmonary artery pressures without an increase in the composite end-point. These results suggest that IABP use before LVAD implantation may mitigate the risk of postoperative complications in ambulatory patients.
One-Year Outcomes of Mitral Valve-in-Valve Using the SAPIEN 3 Transcatheter Heart Valve

JAMA Cardiology | July 29, 2020 | Volume: 5 | Issue: 11 | Pages: 1245

10.1001/jamacardio.2020.2974 | PMID 32745164

Does a Gradient-Adjusted Cardiac Power Index Improve Prediction of Post-Transcatheter Aortic Valve Replacement Survival Over Cardiac Power Index?

Yonsei Medical Journal | May 27, 2020 | Volume: 61 | Issue: 6 | Pages: 482

10.3349/ymj.2020.61.6.482 | PMID 32469172

Remote robotic percutaneous coronary intervention: An animal feasibility study

Catheterization and Cardiovascular Interventions | May 22, 2020 | Volume: 97 | Issue: 3 | Pages: No page available

10.1002/ccd.28978 | PMID 32442332

AbstractObjectivesThe purpose of this study was to explore the feasibility and safety of robotic PCI performed using an off‐siteremote‐control system in an animal model.BackgroundAccess to primary percutaneous coronary intervention (PCI) remains a challenge in acute myocardial infarction management. The combination of telemedicine and robotic PCI allow the potential delivery of primary PCI to remote locations without the delay of transfer.MethodsThis single‐center prospective pilot preclinical feasibility study compared robotic PCI with remote PCI on swine across three stages (adjacent room, different floor of the same building, two different buildings). Latency up to 1,000 ms was introduced into the operating environment to simulate decreased network quality (blinded to operator). The primary outcome measures were technical success and acute safety. The secondary outcome measures included lesion wiring time, procedural time and qualitative scoring of the PCI experience by the operator.ResultsAcross 52 experiments in 15 animals, technical success was 100%. No procedural complications occurred during the study. No significant difference in lesion treatment time was detected between stages (p = .11) and between time per target vessel when latency up to 1,000 ms was introduced (p = .58). Injected delay >250 ms had the greatest impact on procedure perceived lag. Longer procedure time was associated with lower procedure impact score, regardless of injected latency.ConclusionsRemote robotic PCI was feasible and safe in an animal model. Procedural duration was acceptable and unaffected by network latency. Future studies are needed to determine the safety and feasibility of remote PCI in humans.
Robotic Percutaneous Coronary Intervention: Making Gains With Experience

Circulation: Cardiovascular Interventions | May 14, 2020 | Volume: 13 | Issue: 5 | Pages: No page available

10.1161/circinterventions.120.009237 | PMID 32406262

Acute fulminant hemolysis after transcatheter mitral valve replacement for mitral annular calcification

Catheterization and Cardiovascular Interventions | May 6, 2020 | Volume: 96 | Issue: 3 | Pages: 706-711

10.1002/ccd.28944 | PMID 32374902

AbstractTranscatheter mitral valve replacement (TMVR) is emerging as an alternative treatment strategy to surgery for patients with severe mitral annular calcification (MAC) who are not candidates for traditional mitral valve surgery. Paravalvular leak (PVL) is common following TMVR for severe MAC and can lead to heart failure symptoms and/or intravascular hemolysis, the latter of which usually is clinically stable. We report the case of a 67‐year‐old woman with symptomatic severe aortic stenosis and mitral stenosis with MAC in the setting of prior chest irradiation who was treated initially with transcatheter aortic valve replacement followed by TMVR at a later date (Sapien S3 system; Edwards Lifesciences). Immediately following TMVR, she developed acute profound hemolysis which manifested with hemoglobinuria, transfusion‐dependent anemia, and acute renal failure requiring renal replacement therapy. She was treated with post‐dilation balloon valvuloplasty after failed transcatheter PVL closure 10 days following TMVR with resulting improvement in the PVL. The hemolytic anemia resolved and renal function recovered without the need for continued hemodialysis 2 months later and stabilization of glomerular filtration rate at 6 months. This case highlights a potential severe complication of TMVR in MAC and suggests that improvement in hemolysis and late recovery of renal function may occur following treatment of PVL.
Structural Heart Disease Emergencies

Journal of Intensive Care Medicine | April 21, 2020 | Volume: 36 | Issue: 9 | Pages: 975-988

10.1177/0885066620918776 | PMID 32314662

Structural heart disease (SHD) emergencies include acute deterioration of a stable lesion or development of a new critical lesion. Structural heart disease emergencies can produce heart failure and cardiogenic shock despite preserved systolic function that may not respond to standard medical therapy and typically necessitate surgical or percutaneous intervention. Comprehensive Doppler echocardiography is the initial diagnostic modality of choice to determine the cause and severity of the underlying SHD lesion. Patients with chronic SHD lesions which deteriorate due to intercurrent illness (eg, infection or arrhythmia) may not require urgent intervention, whereas patients with an acute SHD lesion often require definitive therapy. Medical stabilization prior to definitive intervention differs substantially between stenotic lesions (aortic stenosis, mitral stenosis, left ventricular outflow tract obstruction) and regurgitant lesions (aortic regurgitation, mitral regurgitation, ventricular septal defect). Patients with regurgitant lesions typically require aggressive afterload reduction and inotropic support, whereas patients with stenotic lesions may paradoxically require β-blockade and vasoconstrictors. Emergent cardiac surgery for patients with decompensated heart failure or cardiogenic shock carries a substantial mortality risk but may be necessary for patients who are not eligible for catheter-based percutaneous SHD intervention. This review explores initial medical stabilization and subsequent definitive therapy for patients with SHD emergencies.
Diastolic blood pressure predicts outcomes after aortic paravalvular leak closure

Catheterization and Cardiovascular Interventions | April 7, 2020 | Volume: 97 | Issue: 1 | Pages: No page available

10.1002/ccd.28890 | PMID 32259389

AbstractObjectivesWe sought to determine hemodynamic effects of aortic paravalvular leak (PVL) and predictors of clinical outcomes after aortic PVL closure.BackgroundThe significance of hemodynamic alterations in PVL and relation to severity, procedural success of percutaneous closure and clinical outcomes have not been defined.MethodsPatients undergoing percutaneous PVL closure between July 21, 2004 and September 10, 2018 were included. PVL severity was assessed by echocardiography and aortic angiography. Hemodynamics were assessed by intra‐arterial pressure tracings before and after PVL closure. The primary outcome was a composite of mortality, redo aortic valve replacement (AVR) and redo PVL closure.ResultsOne hundred and seventeen patients (mean age 70.3 ± 14.9 years, 79% surgical and 21% transcatheter prostheses) underwent PVL closure with 94% technical success. PVL was moderate or greater in 106 (91%) at baseline and 11 (11%) post‐procedure. Diastolic BP for those with moderate or greater PVL was lower than for those with less PVL (50.3 ± 11.7 vs. 56.5 ± 12.4 mmHg, p < .001). Pulse pressure was similar between these groups (69.9 ± 20.3 vs. 67.4 ± 21.2 mmHg, p = .39). 35 patients (34%) had 40 events during a mean follow‐up of 1.6 ± 1.9 years (23 deaths, 12 redo AVR, and five redo PVL closures). In a multivariate model, final diastolic BP <47 mmHg (HR 3.27 [1.45–7.36], p = .007) was a significant predictor of the composite endpoint.ConclusionsDiastolic BP was significantly associated with aortic PVL severity and clinical outcomes after PVL closure. In contrast, pulse pressure did not correlate with PVL severity or outcomes. These findings have implications for clinical management of patients with aortic PVL.