Abstract Background Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death in patients at high risk for ventricular arrhythmias, but conventional systems carry a risk of transvenous (TV) lead-related complications. The novel extravascular ICD (EV ICD) may reduce some of these complications, while offering anti-tachycardia pacing (ATP), pause prevention pacing, and a device of similar size and projected battery longevity as a TV ICD, by placing a lead substernally. The EV ICD Pivotal study demonstrated EV ICD safety and performance for termination of ventricular arrythmias at 6 months. Longer-term performance is unknown. Purpose To report the chronic safety and performance of the EV ICD system. Methods The extravascular implantable cardioverter defibrillator (EV ICD) Pivotal study was a prospective, international, single-arm, premarket clinical study. Patients with a class I or IIa indication for a single-chamber ICD per ESC or ACC/AHA/HRS guidelines were enrolled. Freedom from major system- and/or procedure-related complications at 18 mo was evaluated, as well as conversion of arrhythmias by anti-tachycardia pacing (ATP) or shock through all available follow up. Rates of ATP success were evaluated using the generalized estimating equation (GEE) and simple proportions. Results Implantation was attempted in 316 patients: 74.7% male, age 53.8±13.1 years, 82% primary prevention, left ventricular ejection fraction of 38.9%±15.4%, and New York Heart Association Class I (23.4%) or II/III (65.5%). Of 299 implanted patients (average follow up 16.2±7.2 mo), 19 experienced 80 spontaneous, appropriately treated arrhythmic episodes: 37 treated by ATP, 15 by ATP and shock, and 28 by shock alone with a Kaplan-Meier (KM) estimated 6.8% of patients experiencing appropriate therapy by 18 mo (Figure). Of discrete episodes treated with shock, 21/21 (100%) were successfully terminated. ATP was delivered in 12 patients, successfully treating 35/52 episodes (67.3%; GEE adjusted 59.0%). Inappropriate shocks occurred in 35 patients through all follow up, with a rate of 10.2% at 1 year. The KM estimate of freedom from major EV ICD system-or procedure-related complications rate through 18 mo was 91.9% (95% CI: 88.2% to 94.4%). The most common event was lead dislodgment (10 events in 9 patients) identified 0 to 120 days post-implant, predominantly due to anchoring technique. Conclusion The safety and effectiveness of a novel EV ICD system with a substernal lead extends through chronic follow up. Shocks were avoided in nearly half of all spontaneous episodes because of the availability of ATP.Figure
Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
Background: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. Methods: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. Results: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. Conclusions: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04198701.
Efficacy and Safety of an Extravascular Implantable Cardioverter–Defibrillator
New England Journal of Medicine | August 28, 2022 | Volume: 387 | Issue: 14 | Pages: 1292-1302
AbstractIntroductionThe extravascular implantable cardioverter‐defibrillator (EV ICD) system with substernal lead placement is a novel nontransvenous alternative to current commercially available ICD systems. The EV ICD provides defibrillation and pacing therapies without the potential long‐term complications of endovascular lead placement but requires a new procedure for implantation with a safety profile under evaluation.MethodsThis paper summarizes the development of the EV ICD, including the preclinical and clinical evaluations that have contributed to the system and procedural refinements to date.ResultsExtensive preclinical research evaluations and four human clinical studies with >140 combined acute and chronic implants have enabled the development and refinement of the EV ICD system, currently in worldwide pivotal study.ConclusionThe EV ICD may represent a clinically valuable solution in protecting patients from sudden cardiac death while avoiding the long‐term consequences of transvenous hardware. The EV ICD offers advantages over transvenous and subcutaneous systems by avoiding placement in the heart and vasculature; relative to subcutaneous systems, EV ICD requires less energy for defibrillation, enabling a smaller device, and provides pacing features such as antitachycardia and asystole pacing in a single system.
First-in-Human Experience and Acute Procedural Outcomes Using a Novel Pulsed Field Ablation System: The PULSED AF Pilot Trial
Circulation: Arrhythmia and Electrophysiology | December 29, 2021 | Volume: 15 | Issue: 1 | Pages: No page available
Background: Pulsed field ablation (PFA) is a novel form of ablation using electrical fields to ablate cardiac tissue. There are only limited data assessing the feasibility and safety of this type of ablation in humans. Methods: PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; https://www.clinicaltrials.gov ; unique identifier: NCT04198701) is a nonrandomized, prospective, multicenter, global, premarket clinical study. The first-in-human pilot phase evaluated the feasibility and efficacy of pulmonary vein isolation using a novel PFA system delivering bipolar, biphasic electrical fields through a circular multielectrode array catheter (PulseSelect; Medtronic, Inc). Thirty-eight patients with paroxysmal or persistent atrial fibrillation were treated in 6 centers in Australia, Canada, the United States, and the Netherlands. The primary outcomes were ability to achieve acute pulmonary vein isolation intraprocedurally and safety at 30 days. Results: Acute electrical isolation was achieved in 100% of pulmonary veins (n=152) in the 38 patients. Skin-to-skin procedure time was 160±91 minutes, left atrial dwell time was 82±35 minutes, and fluoroscopy time was 28±9 minutes. No serious adverse events related to the PFA system occurred in the 30-day follow-up including phrenic nerve injury, esophageal injury, stroke, or death. Conclusions: In this first-in-human clinical study, 100% pulmonary vein isolation was achieved using only PFA with no PFA system–related serious adverse events. Graphic Abstract: A graphic abstract is available for this article.
Cover Image, Volume 32, Issue 9
Journal of Cardiovascular Electrophysiology | September 12, 2021 | Volume: 32 | Issue: 9 | Pages: No page available
AbstractBackgroundTransvenous implantable cardioverter defibrillators (TV ICD) provide life‐saving therapy for millions of patients worldwide. However, they are susceptible to several potential short‐ and long‐ term complications including cardiac perforation and pneumothorax, lead dislodgement, venous obstruction, and infection. The extravascular ICD system's novel design and substernal implant approach avoids the risks associated with TV ICDs while still providing pacing features and similar generator size to TV ICDs.Study DesignThe EV ICD pivotal study is a prospective, multicenter, single‐arm, nonrandomized, premarket clinical study designed to examine the safety and acute efficacy of the system. This study will enroll up to 400 patients with a Class I or IIa indication for implantation of an ICD. Implanted subjects will be followed up to approximately 3.5 years, depending on when the patient is enrolled.ObjectiveThe clinical trial is designed to demonstrate safety and effectiveness of the EV ICD system in human use. The safety endpoint is freedom from major complications, while the efficacy endpoint is defibrillation success. Both endpoints will be assessed against prespecified criteria. Additionally, this study will evaluate antitachycardia pacing performance, electrical performance, extracardiac pacing sensation, asystole pacing, appropriate and inappropriate shocks, as well as a summary of adverse events.ConclusionThe EV ICD pivotal study is designed to provide clear evidence addressing the safety and efficacy performance of the EV ICD System.
The Extravascular Implantable Cardioverter-Defibrillator: The Pivotal Study Plan
No container title available | March 23, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available
Background: Transvenous implantable cardiac defibrillators (TV ICD) provide life-saving therapy for millions of patients worldwide. However, they are susceptible to several potential short- and long- term complications including cardiac perforation and pneumothorax, lead dislodgement, venous obstruction, and infection. The extravascular ICD (EV ICD) system’s novel design and substernal implant approach avoids the risks associated with TV ICDs while still providing pacing features and similar generator size to TV ICDs. Study Design: The EV ICD pivotal study is a prospective, multi-center, single-arm, non-randomized, pre-market clinical study designed to examine the safety and acute efficacy of the system. This study will enroll up to 400 patients with a Class I or IIa indication for implantation of an ICD. Implanted subjects will be followed up to approximately 3.5 years, depending on when the patient is enrolled. Objective: The clinical trial is designed to demonstrate safety and effectiveness of the EV ICD system in human use. The safety endpoint is freedom from major complications, while the efficacy endpoint is defibrillation success. Both endpoints will be assessed against prespecified criteria. Additionally, this study will evaluate antitachycardia pacing (ATP) performance, electrical performance, extracardiac pacing sensation, asystole pacing, appropriate and inappropriate shocks, as well as a summary of adverse events. Conclusion: The EV ICD pivotal study is designed to provide clear evidence addressing the safety and efficacy performance of the EV ICD System.