Citations 57

MR elastography of the human abdominal aorta: A preliminary study

Journal of Magnetic Resonance Imaging | January 31, 2013 | Volume: 38 | Issue: 6 | Pages: 1549-1553

10.1002/jmri.24056 | PMID 23371244

PurposeTo investigate the feasibility of using MR elastography (MRE) for the evaluation of the stiffness of in vivo aortic wall.Materials and MethodsTo validate the experimental approach for imaging the aorta in vivo, a gel phantom with an embedded porcine aorta was imaged in the presence of fluid flow within the aorta. The potential changes in the elasticity of the vessel wall with changes in pressure were investigated. The feasibility of performing MRE of abdominal aorta was assessed in five volunteers (age, 22–40 years; body mass index, 21.5–25.2 kg/m2). The pulse‐gated cine MRE technique was used to study the wave propagation along the aorta throughout the cardiac cycle and provide estimates of aortic stiffness in diastole.ResultsIn the phantom study, the wave propagation was well visualized within the porcine aorta embedded in the gel phantom. An increase of the Young's modulus‐wall thickness (E*t) product with the increase in static pressure was observed. In the in vivo study, the waves were well visualized within the lumen of abdominal aorta in the five volunteers in diastolic phase, but they were not well visualized during systole.ConclusionMRE is feasible for noninvasively assessing the stiffness of the abdominal aorta and merits further investigation. J. Magn. Reson. Imaging 2013;38:1549–1553. © 2013 Wiley Periodicals, Inc.
Automated liver stiffness measurements with magnetic resonance elastography

Journal of Magnetic Resonance Imaging | December 21, 2012 | Volume: 38 | Issue: 2 | Pages: 371-379

10.1002/jmri.23980 | PMID 23281171

PurposeTo provide a fully automated algorithm for obtaining stiffness measurements from hepatic magnetic resonance elastography (MRE) images that are consistent with measurements performed by expert readers.Materials and MethodsAn initial liver contour was found using an adaptive threshold and expanded using an active contour to select a homogeneous area of the liver. The confidence map generated during the stiffness calculation was used to select a region of reliable wave propagation. The average stiffness within the automatically generated region of interest (ROI) was compared to measurements by two trained readers in a set of 88 clinical test cases ranging from healthy to severely fibrotic.ResultsThe stiffness measurements reported by the readers differed by −6.76% ± 22.8% (95% confidence) and had an intraclass correlation coefficient (ICC) of 0.972 (P < 0.05). The algorithm and the more experienced reader differed by 4.32% ± 14.9 with an ICC of 0.987.ConclusionThe automated algorithm performed reliably, even though MRE acquisitions often have motion artifacts present. The correlation between the automated measurements and those from the trained readers was superior to the correlation between the readers. J. Magn. Reson. Imaging 2013;38:371–379. © 2013 Wiley Periodicals, Inc.
Abdominal magnetic resonance elastography

The Journal of the Acoustical Society of America | September 24, 2012 | Volume: 132 | Issue: 3_Supplement | Pages: 1981-1981

10.1121/1.4755306

Many disease processes, both focal and diffuse, cause marked changes in cell and tissue mechanical properties. Magnetic resonance elastography (MRE) is a magnetic resonance imaging-based technique for quantitatively assessing the mechanical properties of tissues based on the propagation of shear waves. Multiple studies have demonstrated MRE can be successfully implemented to assess abdominal organs with many potential applications, from detecting diffuse disease processes to characterizing tumors. The first clinical application of MRE to be well documented is the detection and characterization of hepatic fibrosis, which systematically increases the stiffness of liver tissue. In this diagnostic role, it offers a safer, less expensive, and potentially more accurate alternative to invasive liver biopsy. Emerging results also suggest that measurements of liver and spleen stiffness may provide an indirect way to assess portal hypertension. Preliminary studies have demonstrated that it is possible to use MRE to evaluate the mechanical properties of other abdominal structures, such as the pancreas and kidneys. Steady technical progress in developing practical protocols for applying MRE in the abdomen and the pelvis provides opportunities to explore many other potential applications of this emerging technology.
Neuropilin-1 Stimulates Tumor Growth by Increasing Fibronectin Fibril Assembly in the Tumor Microenvironment

Cancer Research | June 27, 2012 | Volume: 72 | Issue: 16 | Pages: 4047-4059

10.1158/0008-5472.can-11-3907 | PMID 22738912

Abstract The tumor microenvironment, including stromal myofibroblasts and associated matrix proteins, regulates cancer cell invasion and proliferation. Here, we report that neuropilin-1 (NRP-1) orchestrates communications between myofibroblasts and soluble fibronectin that promote α5β1 integrin–dependent fibronectin fibril assembly, matrix stiffness, and tumor growth. Tumor growth and fibronectin fibril assembly were reduced by genetic depletion or antibody neutralization of NRP-1 from stromal myofibroblasts in vivo. Mechanistically, the increase in fibronectin fibril assembly required glycosylation of serine 612 of the extracellular domain of NRP-1, an intact intracellular NRP-1 SEA domain, and intracellular associations between NRP-1, the scaffold protein GIPC, and the nonreceptor tyrosine kinase c-Abl that augmented α5β1 fibronectin fibril assembly activity. Analysis of human cancer specimens established an association between tumoral NRP-1 levels and clinical outcome. Our findings indicate that NRP-1 activates the tumor microenvironment, thereby promoting tumor growth. These results not only identify new molecular mechanisms of fibronectin fibril assembly but also have important implications for therapeutic targeting of the myofibroblast in the tumor microenvironment. Cancer Res; 72(16); 4047–59. ©2012 AACR.
Dynamic Postprandial Hepatic Stiffness Augmentation Assessed With MR Elastography in Patients With Chronic Liver Disease

American Journal of Roentgenology | July 1, 2011 | Volume: 197 | Issue: 1 | Pages: 64-70

10.2214/ajr.10.5989 | PMID 21701012

Feasibility of In Vivo MR Elastographic Splenic Stiffness Measurements in the Assessment of Portal Hypertension

American Journal of Roentgenology | June 19, 2009 | Volume: 193 | Issue: 1 | Pages: 122-127

10.2214/ajr.07.3504 | PMID 19542403

MR Elastography of Liver Tumors: Preliminary Results

American Journal of Roentgenology | May 20, 2008 | Volume: 190 | Issue: 6 | Pages: 1534-1540

10.2214/ajr.07.3123 | PMID 18492904