Abstract Background Dose‐driven continuous scanning (DDCS) enhances the efficiency and precision of proton pencil beam delivery by reducing beam pauses inherent in discrete spot scanning (DSS). However, current DDCS optimization studies using traveling salesman problem (TSP) formulations often rely on fixed beam intensity and computationally expensive interpolation for move spot generation, limiting efficiency and methodological robustness. Purpose This study introduces a Break Spot‐Guided (BSG) method, combined with two acceleration strategies—dose rate skipping and bounding—to optimize beam intensity while minimizing beam delivery time (BDT). In addition, a ‐method is proposed for efficient move spot generation, aiming to balance computational efficiency and dose calculation accuracy. Methods The BSG framework simplifies the original mixed‐integer nonlinear programming (MINLP) problem by transforming it into a series of TSP evaluations using break‐spot dose rates. The two acceleration strategies are integrated to reduce computational complexity. The ‐method is introduced to efficiently generate move spots without compromising dose fidelity. The performance of the BSG method, with and without the acceleration strategies, and the ‐method, was evaluated across multiple clinical cases. Results By jointly optimizing the scan path and dose rate, the proposed BSG‐S‐B method offered the most efficient delivery, achieving a 64% reduction in BDT compared to DSS and a 57% reduction compared to Liu's method in the prostate case. These gains were consistently observed across all cases. Utilizing acceleration strategies, BSG‐S‐B significantly reduced computation time from hours to minutes (e.g., from 10 525.7 to 108.5 s in the prostate case, and from 6202.4 to 129.8 s in the head‐and‐neck case). When combined with the ‐method, it reduced the number of move spots by more than 50%, while still ensuring dosimetric quality. Conclusions The proposed framework significantly improves computational efficiency, making scan path optimization with dose rate selection feasible for clinical DDCS delivery. The ‐method effectively reduces computational complexity while maintaining dose calculation accuracy, demonstrating strong potential for clinical adoption in proton therapy treatment planning.
Quality assurance of the inter‐spot beam delivery of a dose driven continuous scanning proton therapy system
Medical Physics | August 14, 2025 | Volume: 52 | Issue: 8 | Pages: No page available
Abstract Background Dose‐driven continuous scanning (DDCS) is a type of beam delivery in Hitachi pencil beam scanning (PBS) particle therapy system. Particle beam is irradiated continuously between spots to achieve a higher effective dose rate and a shorter beam delivery time. The beam is only turned off at break spots, the end of a treatment layer and during spill change. The break spot is a unique feature of the DDCS introduced by the treatment planning system (TPS) to interrupt continuous scanning. DDCS separates the dose delivery of a spot into a move dose and stop dose components. The move dose is controlled by the scanning speed and beam current, while the stop dose delivers the remaining monitor units (MUs). Hence, rigorous quality assurance (QA) of the scanning speed and functionality of break spot are required to ensure safe and successful DDCS delivery. Purpose We aim to report for the first time the QA methodology and result for DDCS, focusing on the scanning speed and break spot validation. Methods A rectangular spiral irradiation pattern with different degree of break spots were irradiated on a 2D strip ionization chamber (CROSSmini) detector using 50 time resolution to validate the break spots. Four methods of measuring scanning speeds were proposed. Using a spiral irradiation pattern, methods one and two applied linear regression to the scanning time measured by the CROSSmini for different inter‐spot distances, with measurements taken at sampling rates of 5 and 20 kHz, respectively. Methods three and four measured the scanning time of single inter‐spot distances in the X and Y directions. Method three measured the scanning time with the CROSSmini while method four measured the rise and fall time of the scanning magnet (SCM) current. All measurements were performed with 70.2, 150.2 and 228.7 MeV proton beam energies and three different beam currents of 8, 14 and 20 MU/s. Lastly, the scanning speed tolerance limit was calculated analytically under the requirement of avoiding a beam abort when the stop dose was less than zero. Results The data recorded by the CROSSmini under the spiral irradiation patterns with break spots was reconstructed into a 2D dose, and the break spots’ operations were visually validated for all the energies and beam currents. There were no statistically significant difference in the measured X and Y scanning speeds across the four methods. However, the last method involving the SCM current yielded the largest type A uncertainty of up to 25% () due to the noisy signal. The first method with the linear regression and 5 kHz acquisition rate was preferred due to a smaller type A uncertainty of up to 2.0% and a lower false negative rate in detecting the rising and falling edges during scanning. The calculated tolerance limit based on our current DDCS setting was found to be 0.50 times of the expected scanning speed. Conclusion We have introduced QA protocols for DDCS, designed to ensure complete and safe beam delivery without interruptions caused by move doses exceeding planned spot doses.
Redundancy‐weighted FDK reconstruction for dual‐detector combined‐scanning CBCT: Practical implementation for image guided particle therapy
Medical Physics | August 9, 2025 | Volume: 52 | Issue: 8 | Pages: No page available
Abstract Background Cone‐beam computed tomography (CBCT) is essential for image‐guided particle therapy (IGPT), providing daily patient positioning, anatomical monitoring, and treatment verification. However, conventional single‐detector CBCT suffers from poor soft‐tissue contrast, long acquisition times, and motion artifacts, reducing its effectiveness for adaptive radiotherapy workflows. Addressing these challenges requires an advanced CBCT reconstruction approach capable of enhancing image quality while reducing scan time and radiation exposure. Purpose This study introduces a Dual Detector Combined Scanning (DDCS) CBCT reconstruction algorithm to overcome conventional CBCT limitations. By integrating a dual‐source, orthogonal imaging setup, DDCS significantly reduces scanning time and imaging artifacts. A modified Parker‐weighting algorithm further improves image reconstruction accuracy, ensuring high‐fidelity visualization. The goal is to enhance adaptive radiotherapy by improving real‐time patient positioning, dose verification, and motion management. Methods A dual‐detector CBCT system was designed to acquire orthogonal projections simultaneously, reducing scan time and improving data completeness. A modified Parker‐weighting algorithm corrected angular overlap distortions, ensuring better reconstruction accuracy. The system was evaluated using numerical and physical phantom studies to assess spatial resolution, contrast‐to‐noise ratio (CNR), and artifact reduction. Additionally, a dynamic phantom simulated respiratory motion, validating motion robustness for adaptive radiotherapy. Performance was compared against single‐detector CBCT, focusing on image fidelity, noise suppression, and computational efficiency. Results DDCS‐CBCT demonstrated higher CNR, reduced motion artifacts, and improved spatial resolution, leading to more accurate anatomical visualization. The system's efficiency enables faster, more reliable patient setup in IGPT while maintaining a lower imaging dose. Conclusion The proposed DDCS‐CBCT approach significantly improves imaging accuracy, reduces scan time, and enhances real‐time volumetric guidance in IGRT/IGPT. These findings support the clinical feasibility of the DDCS system and its integration into online adaptive radiotherapy workflows.
Enhancing proton therapy quality assurance with custom‐designed Octopoint phantom and Gafchromic film
Journal of Applied Clinical Medical Physics | July 14, 2025 | Volume: 26 | Issue: 7 | Pages: No page available
Abstract Background Proton therapy offers precise tumor targeting while minimizing damage to surrounding healthy tissue, making it especially valuable for treating tumors near critical organs and in pediatric patients. However, its success depends on accurate beam delivery, requiring rigorous quality assurance (QA) to maintain treatment precision and effectiveness. Purpose This study aims to standardize the measurement of key aspects of proton therapy delivery, such as gantry and couch isocentricity, spot position accuracy, and spot size consistency. The goal is to enhance the delivery accuracy of proton therapy across various clinical settings, improving patient outcomes. Methods The QA framework uses the Octopoint phantom, Gafchromic film, and spot position monitor (SPM) log data to evaluate proton beam isocentricity, spot position, and spot size. The Octopoint phantom, made from acrylic, was used with Gafchromic films at various gantry and couch angles to measure isocentricity. MATLAB tools were used to analyze spot positions, and SPM logs provided verification. Sensitivity tests were conducted to assess the system's response to intentional shifts and errors, ensuring alignment with clinical QA standards. Results The Octopoint phantom's stepwise two‐dimensional (2D) fitting process, validated against film‐measured dose profiles, accurately identified beam and ball bearing (BB) centroid locations. Isocentricity tests conducted over 8 months across four gantries demonstrated consistent beam‐to‐BB radial offsets. The phantom showed excellent repeatability, with a maximum standard deviation of 0.1 mm across various couch‐gantry combinations. Sensitivity testing across all axes revealed a strong alignment between intended shifts and measured values. Over the course of a year, film measurements tracked spot position and size consistency, with deviations remaining within acceptable clinical limits. Comparisons with SPM data further confirmed the system's reliability in maintaining beam accuracy across different gantry angles and energy levels. Conclusions This study presents a reliable QA framework for ensuring precision in proton therapy delivery. By combining the Octopoint phantom, Gafchromic film analysis, and SPM log file evaluation, we effectively measured isocentricity, spot position accuracy, and spot size stability. The framework demonstrated adaptability across various clinical QA tasks, enhancing the accuracy and safety of proton therapy treatments.
Impact of Microdosimetric Modeling on Computation of Relative Biological Effectiveness for Carbon Ion Radiotherapy
Microdosimetry plays a critical role in particle therapy by quantifying energy deposition within microscopic domains to assess biological effects. This study evaluates the influence of different microdosimetric functions (MFs) and domain geometries (DGs) on relative biological effectiveness (RBE) predictions in carbon ion radiotherapy. Specifically, we compare the analytical microdosimetric function (AMF), calculated for spherical domains and implemented in PHITS, with the Kiefer–Chatterjee (KC) track structure model, which is conventionally applied to cylindrical geometries. To enable a direct comparison, we also introduce a novel implementation of the KC model for spherical domains. Using both models, specific energy distributions were calculated across a range of domain sizes and geometries. These distributions were input into the modified microdosimetric kinetic model (mMKM) to calculate RBE for the HSG cell line and compared against published in vitro data. The results show that both microdosimetric function and domain geometry significantly affect microdosimetric spectra and the resulting RBE, with deviations exceeding 10% when fixed mMKM parameters are used. Parameter optimization within the mMKM enables alignment across models. Our findings emphasize that microdosimetric function and domain geometry selection must be explicitly accounted for in microdosimetry-based RBE modeling, and that model parameters must be tuned accordingly to ensure consistent and biologically accurate predictions.
Impact of nuclear fragmentation and irradiation scenarios on the dose‐averaged LET, the RBE, and their relationship for H, He, C, O, and Ne ions
Medical Physics | March 18, 2025 | Volume: 52 | Issue: 5 | Pages: 3450-3460
Abstract Background Projectile and target fragmentation are nuclear phenomena that can influence the computation of the linear energy transfer (LET) and the relative biological effectiveness (RBE) in external radiotherapy with accelerated ions. Correlations between these two quantities are routinely established during radiobiological experiments to interpret the results and to develop and calibrate RBE models. Purpose This study systematically evaluates the impact of secondary fragments and irradiation scenarios on the dose‐averaged LET, the RBE, and their correlation in the case of exposures to clinically relevant ion beams. Methods 57 600 microdosimetric lineal energy spectra and corresponding LET distributions were simulated with the Monte Carlo code PHITS across different scenarios, including track segment calculations, pristine, and spread‐out Bragg peaks of 1 H, 4 He, 12 C, 16 O, and 20 Ne ions within water phantoms. The LET distributions were analyzed to calculate the dose‐average LET, both including or excluding the contribution of secondary ions of an element different from the primary beam. Similarly, the lineal energy distributions were processed in conjunction with the Mayo Clinic Florida microdosimetric kinetic model to compute the RBE for two theoretical cell lines ( α / β = 2 and 10 Gy in the case of 6 MV x‐rays). Correlations between the RBE and dose‐averaged LET were established by analyzing the simulation results within water phantoms and then compared to the corresponding trends from the track segment calculations. Results Excluding secondary fragments had a pronounced impact on the dose‐averaged LET and the RBE, particularly in the entrance regions of proton beams and close to the distal edge of heavier ions. The correlations between the RBE and the dose‐averaged LET were not universal, but highly dependent on the irradiation scenario. For proton beams only, the dose‐averaged LET of hydrogen ions served as a practical first‐order descriptor of the RBE. Track segment simulations, commonly used for calibrating and benchmarking RBE models, provided a reasonable approximation for low‐energy beams but failed to fully capture the complexity of polyenergetic radiation fields. Conclusions Secondary fragments can substantially affect the dose‐averaged LET and the RBE, even in proton beams. The dose‐averaged LET, including or not the contributions from secondary fragments, was generally unable to adequately capture RBE variations across different scenarios. A more comprehensive approach, considering microdosimetric distributions, is necessary to accurately describe RBE variations in ion therapy.
Reproducing the NIRS-QST Clinical Dose Calculations for Carbon Ion Radiotherapy Using Microdosimetric Probability Density Distributions
Ion radiotherapy requires accurate relative biological effectiveness (RBE) calculations to account for the markedly different biological effects of ions compared to photons. Microdosimetric RBE models rely on descriptions of the energy deposition at the microscopic scale, either through radial dose distributions (RDDs) or microdosimetric probability density distributions. While RDD approaches focus on the theoretical description of the energy deposition around the ion track, microdosimetric distributions offer the advantage of being experimentally measurable, which is crucial for quality assurance programs. As the results of microdosimetric RBE models depend on whether RDD or microdosimetric distributions are used, the model parameters are not interchangeable between these approaches. This study presents and validates a method to reproduce the published reference biological and clinical dose calculations at NIRS-QST for only carbon ion radiotherapy by using the modified microdosimetric kinetic model (MKM) alongside microdosimetric distributions instead of the reference RDD approach. To achieve this, Monte Carlo simulations were performed to estimate the variation of the radiation quality within and outside the field of pristine and spread-out Bragg peaks. By appropriately optimizing the modified MKM parameters for microdosimetric distributions assessed within water spheres, we successfully reproduced the results of calculations using the reference NIRS-QST RDD, generally within 2%.
Dosimetric study of synchrotron rapid beam off control and skip spot function for high beam intensity proton therapy
Medical Physics | December 16, 2024 | Volume: 52 | Issue: 3 | Pages: 1867-1877
Abstract Background All Hitachi proton pencil beam scanning facilities currently use discrete spot scanning (DSS). Mayo Clinic Florida (MCF) is installing a Hitachi particle therapy system with advanced technologies, including fast scan speeds, high beam intensity, rapid beam off control (RBOC), a skip spot function, and proton pencil beam scanning using dose driven continuous scanning (DDCS). A potential concern of RBOC is the generation of a shoulder at the end of the normal spot delivery due to a flap spot (FS) with a flap dose (FD), which has been investigated for carbon synchrotron but not for proton delivery. While investigated, for instance, for Hitachi's installation at MCF, this methodology could be applicable for all future high intensity proton deliveries. Purpose No Hitachi proton facility currently uses the proposed RBOC. This study aimed to understand the dosimetric impact of proton FD at MCF by simulating the FS with a Hitachi proton machine in research mode, reflecting the higher proton intensities expected with RBOC at MCF. Method Experiments were conducted to simulate MCF RBOC at Kyoto Prefecture University of Medicine (KPUM) in research mode, reducing delay time (Td) from 1.5 ms to 0.1 ms. 5,000 contiguous spots were delivered on the central axis for proton energies of 70.2, 142.5, and 220.0 MeV; at normal, high dose rate (HDR), and ultra‐high dose rate (uHDR) intensities; and at vertical and horizontal gantry angles for different Td. Measurements were taken using a fast oscilloscope and the nozzle's spot position monitor (SPM) and dose monitor (DM). A model was developed to predict FD dependence on beam intensity and assess the dosimetric impact for prostate and brain treatment plans. Two simulation types were planned: a flap DSS plan with FS at every spot and a flap DDCS plan with FS only at the end of each layer. Result FD was observed for RBOC with Td = 0.1 ms, showing no gantry angle dependence. FD increased with higher delayed dose rate (DDR), that is, beam intensity. The planning study showed dose volume histogram deterioration with increased FD compared to the clinical plan, but it was only significant for uHDR intensities. Deterioration was marginal in flap DSS plans for the HDR intensities planned at MCF, and flap DDCS plans were even less sensitive than flap DSS plans. Conclusion MCF is installing proton DDCS with higher beam intensities, a skip spot function, and fast beam‐off control. The resulting FD had an insignificant impact on dose distribution for two patient plans with both DSS and DDCS at the anticipated MCF intensities. However, significant dependence was observed in the case of uHDR. A method to measure the position and dose of the FS during commissioning is described in addition to recommendations for regular QA and log‐based proton patient‐specific quality assurance.
Exploring the LET dependence of DNA DSB repair kinetics using the DR DNA database
Journal of Radiation Research | September 16, 2024 | Volume: 65 | Issue: 5 | Pages: 651-657
Abstract The repair of DNA double-strand breaks is a crucial yet delicate process which is affected by a multitude of factors. In this study, our goal is to analyse the influence of the linear energy transfer (LET) on the DNA repair kinetics. By utilizing the database of repair of DNA and aggregating the results of 84 experiments, we conduct various model fits to evaluate and compare different hypothesis regarding the effect of LET on the rejoining of DNA ends. Despite the considerable research efforts dedicated to this topic over the past decades, our findings underscore the complexity of the relationship between LET and DNA repair kinetics. This study leverages big data analysis to capture overall trends that single experimental studies might miss, providing a valuable model for understanding how radiation quality impacts DNA damage and subsequent biological effects. Our results highlight the gaps in our current understanding, emphasizing the pressing need for further investigation into this phenomenon.
Does the Maximum Initial Beam Energy for Proton Therapy Have to Be 230 MeV?
Proton therapy is increasingly widespread and requires an accelerator to provide the high energy protons. Most often, the accelerators used for proton therapy are cyclotrons and the maximum initial beam energy (MIBE) is about 230 MeV or more to be able to achieve a range of approximately 30 cm in water. We ask whether such a high energy is necessary for adequate dosimetry for pathologies to be treated with proton beams. Eight patients of different clinical sites (brain, prostate, and head and neck cancers) were selected to conduct this study. We analyzed the tumor dose coverage and homogeneity, as well as healthy tissue protection for MIBE values of 120, 160, 180, 200 and 230 MeV. For each patient, a proton plan was developed using the particular MIBE and then using multifield optimization (MFO). In this way, 34 plans in total were generated to fulfill the unique clinical goals. This study found that MIBE of 120 MeV for brain tumors; 160 MeV for head and neck cancer; and remarkably, for prostate cancer, only 160 MeV for one patient case and 180 MeV for the remainder satisfied the clinical goals (words: 187 < approx. 200 words or less)