Nonisotopic "sandwich" immunoassay of thyroglobulin in serum by the biotin-streptavidin technique: evaluation and comparison with an immunoradiometric assay.
Abstract In this sequential assay, the thyroglobulin in serum binds to polystyrene beads coated with two mouse monoclonal antibodies. These beads then react with a rabbit polyclonal antibody, biotinylated sheep anti-rabbit IgG, streptavidin-horseradish peroxidase, and a peroxidase substrate to yield a colored product that is measured spectrophotometrically at 492 nm. The range of the standard curve is 1.6 to 100 micrograms/L. The detection limit of the assay is 1.2 micrograms/L. The interassay coefficient of variation is 14.0% at 6.2 micrograms/L, 5.7% at 32.7 micrograms/L; the intra-assay CVs range from 7.8% to 14.8%. The reference intervals are 2.7 to 42.1 micrograms/L for euthyroid persons and less than or equal to 5 micrograms/L for athyreotic patients not on thyroxin replacement therapy. Some autoantibodies to thyroglobulin cause thyroglobulin values to be falsely low. The concentration of autoantibodies is not correlated with the analytical recovery of human thyroglobulin. The coefficient of correlation between the measurement of thyroglobulin by this assay and by an immunoradiometric assay was 0.969 for 186 autoantibody-negative samples, 0.963 for 37 autoantibody-positive samples.
Bioassay of parathyrin: analytical characteristics and clinical performance in patients with hypercalcemia.
Abstract This new bioassay for parathyrin (PTH) in plasma (bio-PTH) combines immunoextraction on affinity columns [goat anti-hPTH (1-44) conjugated to Sepharose 4B] and a receptor assay involving an osteosarcoma cell line. The mean extraction efficacy ranges from 87% (as determined with immunopurified 125I-labeled PTH) to 62% for hPTH bioactivity. The assay is standardized with synthetic hPTH (1-84) and can detect as little as 0.9 pmol/L of PTH in 2 mL of plasma. In 100 healthy adults, the 95% reference interval for bio-PTH was less than 0.9 to 6.1 pmol/L (median, 2.0 pmol/L). In 185 patients with surgically confirmed hyperparathyroidism, bio-PTH concentrations ranged from 1.0 to greater than 120 pmol/L (median, 12.9 pmol/L); 80% of values were greater than 6.1 pmol/L. In 50 patients with both preoperative and postoperative determinations, the mean (+/--SD) concentrations of calcium in serum were 113 +/- 10 and 89 +/- 6 mg/L, respectively; the median bio-PTH concentrations were 13.6 and 2.0 pmol/L, respectively. In 22 patients with nonparathyroid-mediated hypercalcemia, the concentration of bio-PTH ranged from less than 0.9 to 5.3 pmol/L (median, 1.8 pmol/L). This bio-PTH assay is slightly less sensitive than our GP235 immunoreactive PTH (iPTH) immunoassay for detecting hyperparathyroidism (Clin Chem 1982;28:69-74); however, the bioassay is more specific and detected some cases missed by the iPTH assay. Overall, 95% of the hyperparathyroid patients had an increased test result for either the bio-PTH or the iPTH assay.
Linking medical needs and performance goals: clinical and laboratory perspectives on thyroid disease
Abstract Diagnosis and management of thyroid disease benefit substantially from close interactions between clinicians and laboratorians. Clinicians desire reliable tests for diagnosis and management of both hypothyroidism and thyrotoxicosis. Traditionally, multitiered testing has been used, beginning with an index of free thyroxine concentration, which, if abnormal, has been followed by basal thyrotropin (TSH) measurements (for hypothyroidism) or thyrotropin-releasing hormone-stimulated TSH measurements (for thyrotoxicosis). Improvements in analytical methods for TSH have made it practical to use basal TSH measurements in serum as the first-line test for thyroid disease. However, performance guidelines are needed, because not all TSH assays work well in this role. The performance guidelines developed by the American Thyroid Association are reviewed to illustrate how they help to assure consistent analytical testing. Further improvements in TSH assays (third- and fourth-generation assays), which support measurements down to 0.01 mlU/L and 0.001 mIU/L, may provide additional advantages for classifying thyrotoxic patients and monitoring thyroxine-suppressive therapy in patients with thyroid cancer. The potential advantages of these newer assays are illustrated with case examples. Additional analytical performance monitors are proposed to help ensure that these next-generation TSH assays meet the expanded clinical needs.
American Thyroid Association assessment of current free thyroid hormone and thyrotropin measurements and guidelines for future clinical assays. The Committee on Nomenclature of the American Thyroid Association
Abstract I propose a method for defining tolerance limits for assay bias and assay imprecision, based on the effects of these tolerance limits on the clinical specificity of the assay. An analytical "error budget" is defined as the squared sums of the imprecision and bias errors. The maximum limit for this error budget is set at a value corresponding to a 50% increase in the false-positive rate for classifying healthy subjects. For gaussian distributions with +/- 2 SD used as decision limits, this error budget equates to 0.45 SD of combined within-person and between-person biological variation (SDBiol). To provide reasonable power for bias detection in an assay, I recommend that the SD of the assay be kept at less than half the bias limit. Then, for the gaussian distribution, the maximum bias limit should be < 0.36 SDBiol and the SD of the assay should be < 0.18 SDBiol. Procedures are provided for using the same principles to define tolerance limits for decision limits other than +/- 2 SD and for nongaussian distributions.
Multisite Immunochemiluminometric Assay for Simultaneously Measuring Whole-Molecule and Amino-Terminal Fragments of Human Parathyrin
Abstract The immunochemiluminometric assay described uses immobilized anti-human parathyrin (parathyroid hormone, hPTH)(1-44) and anti-hPTH(44-68) antisera and acridinium ester-labeled anti-hPTH(1-34) to simultaneously measure both intact hPTH and its amino-terminal fragments. Results by the assay correlate well with those by a cAMP-based bioassay and the Nichols Allegro immunoradiometric assay. The minimal detection limit is 0.08 pmol/L. The normal range is 1.0-5.0 pmol/L, and values are higher in older women. About 90% of study patients with surgically proven parathyroid adenomas had above-normal preoperative PTH concentrations, whereas patients with hypercalcemia of malignancy had normal or suppressed values. This assay was designed to detect both intact PTH and amino-terminal PTH fragments; however, chromatographic fractionation of pools of primary and secondary hyperparathyroid plasma showed virtually no amino-terminal fragment activity. Nonetheless, the design is important because the absence of carboxyl-terminal binding sites prevents interference by carboxyl-terminal fragments and because bioactive amino-terminal fragments will react in the assay if they are present in the patients' sera or if they are produced by in vitro proteolysis of intact PTH.
Clinical usage recommendations and analytic performance goals for total and free triiodothyronine measurements
Abstract The major clinical role for total triiodothyronine (TT3) and (or) free T3 (FT3) is the assessment of hyperthyroidism in patients with suppressed sensitive thyrotropin (sTSH) concentrations. The assays are particularly important in hyperthyroid patients with normal free thyroxine (FT4) concentrations to assess potential T3 thyrotoxicosis. Other specialized uses for T3 and FT3 measurements are monitoring thyroid hormone replacement therapy, the evaluation of amiodarone-induced thyrotoxicosis, and predicting outcome of antithyroid drug therapy in patients with Graves hyperthyroidism. The roles of these tests in assessing heart function in cardiopulmonary bypass surgery, evaluation of patients with neuropsychiatric disorders, and monitoring of patients on anticonvulsant therapy are not well defined. These assays are not recommended for diagnosis of hypothyroidism. Analytic recommendations include CV < 5.2% for T3 and < 3.8% for FT3; < 0.2% cross-reactivity with L-T4; and < 1.0% cross-reactivity with D-T4, D-T3, and reverse T3.
Kallikrein markers performance in pretreatment blood to predict early prostate cancer recurrence and metastasis after radical prostatectomy among very high‐risk men
The Prostate | October 11, 2019 | Volume: 80 | Issue: 1 | Pages: 51-56
AbstractBackgroundTo assess whether a prespecified statistical model based on the four kallikrein markers measured in blood—total, free, and intact prostate‐specific antigen (PSA), together with human kallikrein‐related peptidase 2 (hK2)—or any individual marker measured in pretreatment serum were associated with biochemical recurrence‐free (BCR) or metastasis‐free survival after radical prostatectomy (RP) in a subgroup of men with very high‐risk disease.MethodsWe identified 106 men treated at Mayo Clinic from 2004 to 2008 with pathological Gleason grade group 4 to 5 or seminal vesicle invasion at RP. Univariable and multivariable Cox models were used to test the association between standard predictors (Kattan nomogram and GPSM [Gleason, PSA, seminal vesicle and margin status] score), kallikrein panel, and individual kallikrein markers with the outcomes.ResultsBCR and metastasis occurred in 67 and 30 patients, respectively. The median follow‐up for patients who did not develop a BCR was 10.3 years (interquartile range = 8.2‐11.8). In this high‐risk group, neither Kattan risk, GPSM score, or the kallikrein panel model was associated with either outcome. However, after adjusting for Kattan risk and GPSM score, separately, preoperative intact PSA was associated with both outcomes while hK2 was associated with metastasis‐free survival.ConclusionsConventional risk prediction tools were poor discriminators for risk of adverse outcomes after RP (Kattan risk and GPSM risk) in patients with very high‐risk disease. Further studies are needed to define the role of individual kallikrein marker forms in the blood to predict adverse prostate cancer outcomes after RP in this high‐risk setting.
Reference Intervals
American Journal of Clinical Pathology | July 16, 2018 | Volume: 150 | Issue: 6 | Pages: 545-554
To address the role of atrial natriuretic factor (ANF) in hypothyroidism in the control of cardiorenal-endocrine function during volume loading, the relationships between atrial pressure, ANF, the renin-angiotensin-aldosterone system, and renal hemodynamic and excretory function were examined during and after acute 10% body wt saline volume infusion in pentobarbital-anesthetized hypothyroid dogs (n = 8). Hormonal changes before and after thyroidectomy were also evaluated. Four to 6 wk after thyroidectomy, ANF decreased and arginine vasopressin (AVP) and plasma renin activity (PRA) increased. Acute saline volume expansion caused an increase in ANF and decreases in AVP and PRA. Atrial pressure increased throughout volume expansion. Despite the absence of an increase in glomerular filtration rate (GFR) during volume expansion, urinary sodium excretion increased due to a marked rise in fractional excretion of sodium. These studies demonstrate that in hypothyroidism 1) ANF is decreased; 2) despite the decrease in basal ANF, increases in atrial pressure can stimulate relase of ANF; 3) despite the absence of an increase in GFR during volume expansion, fractional excretion of sodium increases associated with an increase in ANF; and 4) a lack of an increase in GFR during volume expansion is not related to an inability to increase ANF.