Citations 71

Computed Tomographic Biomarkers in Idiopathic Pulmonary Fibrosis. The Future of Quantitative Analysis

American Journal of Respiratory and Critical Care Medicine | July 9, 2018 | Volume: 199 | Issue: 1 | Pages: 12-21

10.1164/rccm.201803-0444pp | PMID 29986154

Assessment of Interstitial Lung Disease Using Lung Ultrasound Surface Wave Elastography

Journal of Thoracic Imaging | June 5, 2018 | Volume: 34 | Issue: 5 | Pages: 313-319

10.1097/rti.0000000000000334 | PMID 29877916

Purpose: Optimal strategies to detect early interstitial lung disease (ILD) are unknown. ILD is frequently subpleural in distribution and affects lung elasticity. Lung ultrasound surface wave elastography (LUSWE) is a noninvasive method of quantifying superficial lung tissue elastic properties. In LUWSE a handheld device applied at the intercostal space vibrates the chest at a set frequency, and the lung surface wave velocity is measured by an ultrasound probe 5 mm away in the same intercostal space. We explored LUWSE’s ability to detect ILD and correlated LUSWE velocity with physiological, quantitative, and visual radiologic features of subjects with known ILD and of healthy controls. Materials and Methods: Seventy-seven subjects with ILD, mostly caused by connective tissue disease, and 19 healthy controls were recruited. LUSWE was performed on all subjects in 3 intercostal lung regions bilaterally. Comparison of LUSWE velocities pulmonary function testing, visual assessment, and quantitative analysis of recent computed tomographic imaging with Computer-Aided Lung Informatics for Pathology Evaluation and Rating (CALIPER) software. Results: Sonographic velocities were higher in all lung regions for cases, with the greatest difference in the lateral lower lung. Median velocity in m/s was 5.84 versus 4.11 and 5.96 versus 4.27 (P<0.00001) for cases versus controls, left and right lateral lower lung zones, respectively. LUSWE velocity correlated negatively with vital capacity and positively with radiologist and CALIPER-detected interstitial abnormalities. Conclusions: LUSWE is a safe and noninvasive technique that shows high sensitivity to detect ILD and correlated with clinical, physiological, radiologic, and quantitative assessments of ILD. Prospective study in detecting ILD is indicated.
Effect of Recombinant Human Pentraxin 2 vs Placebo on Change in Forced Vital Capacity in Patients With Idiopathic Pulmonary Fibrosis

JAMA | May 20, 2018 | Volume: 319 | Issue: 22 | Pages: 2299

10.1001/jama.2018.6129 | PMID 29800034

Predicting Outcomes in Idiopathic Pulmonary Fibrosis Using Automated Computed Tomographic Analysis

American Journal of Respiratory and Critical Care Medicine | April 23, 2018 | Volume: 198 | Issue: 6 | Pages: 767-776

10.1164/rccm.201711-2174oc | PMID 29684284

Abstract Rationale Quantitative computed tomographic (CT) measures of baseline disease severity might identify patients with idiopathic pulmonary fibrosis (IPF) with an increased mortality risk. We evaluated whether quantitative CT variables could act as a cohort enrichment tool in future IPF drug trials. Objectives To determine whether computer-derived CT measures, specifically measures of pulmonary vessel–related structures (VRSs), can better predict functional decline and survival in IPF and reduce requisite sample sizes in drug trial populations. Methods Patients with IPF undergoing volumetric noncontrast CT imaging at the Royal Brompton Hospital, London, and St. Antonius Hospital, Utrecht, were examined to identify pulmonary function measures (including FVC) and visual and computer-derived (CALIPER [Computer-Aided Lung Informatics for Pathology Evaluation and Rating] software) CT features predictive of mortality and FVC decline. The discovery cohort comprised 247 consecutive patients, with validation of results conducted in a separate cohort of 284 patients, all fulfilling drug trial entry criteria. Measurements and Main Results In the discovery and validation cohorts, CALIPER-derived features, particularly VRS scores, were among the strongest predictors of survival and FVC decline. CALIPER results were accentuated in patients with less extensive disease, outperforming pulmonary function measures. When used as a cohort enrichment tool, a CALIPER VRS score greater than 4.4% of the lung was able to reduce the requisite sample size of an IPF drug trial by 26%. Conclusions Our study has validated a new quantitative CT measure in patients with IPF fulfilling drug trial entry criteria—the VRS score—that outperformed current gold standard measures of outcome. When used for cohort enrichment in an IPF drug trial setting, VRS threshold scores can reduce a required IPF drug trial population size by 25%, thereby limiting prohibitive trial costs. Importantly, VRS scores identify patients in whom antifibrotic medication prolongs life and reduces FVC decline.
Lung ultrasound surface wave elastography for assessing interstitial lung disease

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1776-1776

10.1121/1.5035812

A lung ultrasound surface wave elastography (LUSWE) technique is developed for assessing interstitial lung disease (ILD). In LUSWE, a 0.1 second harmonic vibration is generated on the chest wall of a subject using a handheld vibrator. An ultrasound probe is aligned with the vibration indenter in the same intercostal region to measure the generated surface wave speed of the lung. A human subject is examined in a sitting position. The lung is tested at the total lung volume. The upper anterior lungs are tested through the second intercostal space in the mid-clavicular line. The lower lateral lungs are tested in the mid-axillary line and the lower posterior lungs are tested in the mid-scapular line. In a prospective clinical study, we measure both lungs through the six intercostal regions for patients and healthy controls. The surface wave speed is measured at 100 Hz, 150 Hz, and 200 Hz. Significant differences of wave speed between patients and controls were found in all lung regions at all frequencies. We also found positive correlation between LUSWE and CT analyses. LUSWE is a safe and noninvasive technique for generating and measuring surface wave propagation on the lung. LUSWE may be useful for assessing ILD.
Likelihood of pulmonary hypertension in patients with idiopathic pulmonary fibrosis and emphysema

Respirology | December 13, 2017 | Volume: 23 | Issue: 6 | Pages: 593-599

10.1111/resp.13231 | PMID 29237236

ABSTRACT Background and objective This study evaluated whether patients with combined pulmonary fibrosis and emphysema (CPFE) have an increased likelihood of pulmonary hypertension (PHT) when compared with idiopathic pulmonary fibrosis (IPF) patients without emphysema. Methods Two consecutive IPF populations having undergone transthoracic echocardiography were examined ( n = 223 and n = 162). Emphysema and interstitial lung disease (ILD) extent were quantified visually; ILD extent was also quantified by a software tool, CALIPER. Echocardiographic criteria categorized PHT risk. Results The prevalence of an increased PHT likelihood was 29% and 31% in each CPFE cohort. Survival at 12 months was 60% across both CPFE cohorts with no significantly worsened outcome identified when compared with IPF patients without emphysema. Using logistic regression models in both cohorts, total computed tomography (CT) disease extent (ILD and emphysema) predicted the likelihood of PHT. After adjustment for total disease extent, CPFE had no stronger association with PHT likelihood than IPF patients without emphysema. Conclusion Our findings indicate that the reported association between CPFE and PHT is explained by the summed baseline CT extents of ILD and emphysema. Once baseline severity is taken into account, CPFE is not selectively associated with a malignant microvascular phenotype, when compared with IPF patients without emphysema.
Short-term Automated Quantification of Radiologic Changes in the Characterization of Idiopathic Pulmonary Fibrosis Versus Nonspecific Interstitial Pneumonia and Prediction of Long-term Survival

Journal of Thoracic Imaging | December 6, 2017 | Volume: 33 | Issue: 2 | Pages: 124-131

10.1097/rti.0000000000000317 | PMID 29219887

Purpose: Fibrotic interstitial lung diseases presenting with nonspecific and overlapping radiologic findings may be difficult to diagnose without surgical biopsy. We hypothesized that baseline quantifiable radiologic features and their short-term interval change may be predictive of underlying histologic diagnosis as well as long-term survival in idiopathic pulmonary fibrosis (IPF) presenting without honeycombing versus nonspecific interstitial pneumonia (NSIP). Materials and Methods: Forty biopsy-confirmed IPF and 20 biopsy-confirmed NSIP patients with available high-resolution chest computed tomography 4 to 24 months apart were studied. CALIPER software was used for the automated characterization and quantification of radiologic findings. Results: IPF subjects were older (66 vs. 48; P<0.0001) with lower diffusion capacity for carbon monoxide and higher volumes of baseline reticulation (193 vs. 83 mL; P<0.0001). Over the interval period, compared with NSIP, IPF patients experienced greater functional decline (forced vital capacity, −6.3% vs. −1.7%; P=0.02) and radiologic progression, as noted by greater increase in reticulation volume (24 vs. 1.74 mL; P=0.048), and decrease in normal (−220 vs. −37.7 mL; P=0.045) and total lung volumes (−198 vs. 58.1 mL; P=0.03). Older age, male gender, higher reticulation volumes at baseline, and greater interval decrease in normal lung volumes were predictive of IPF. Both baseline and short-term changes in quantitative radiologic findings were predictive of mortality. Conclusions: Baseline quantitative radiologic findings and assessment of short-term disease progression may help characterize underlying IPF versus NSIP in those with difficult to differentiate clinicoradiologic presentations. Our study supports the possible utility of assessing serial quantifiable high-resolution chest computed tomographic findings for disease differentiation in these 2 entities.
Abstract 3723: Assessing the reproducibility of computer-aided nodule assessment and risk yield (CANARY) method to characterize lung adenocarcinomas

Cancer Research | July 31, 2017 | Volume: 77 | Issue: 13_Supplement | Pages: 3723-3723

10.1158/1538-7445.am2017-3723

Abstract This study assessed the inter-user reproducibility of Computer-Aided Nodule Assessment and Risk Yield (CANARY), a novel analytical tool that risk stratifies lung adenocarcinomas (ADCs) according to defined computed tomography (CT) structural characteristics. CANARY detects nine distinct voxel signatures in ADCs based on standard CT imaging, thereby defining nodule characteristics correlating with patient outcomes, and corresponding to invasion or lepidic growth histologically. A software user segments the borders of each ADC prior to voxel analysis, introducing potential variability into the assessment. While CANARY is a promising method, it requires validation of the analytical variability between users and prediction of accuracy in an independent cohort. To evaluate the reproducibility of CANARY analysis, three independent users who are not part of the CANARY development team segmented and analyzed 50 biopsy-confirmed primary lung ADCs from Vanderbilt University Medical Center. The CT scans of ADCs were selected retrospectively based on the following criteria: ADC-histology proven on biopsy, diagnosed between 2009-2015, less than 3cm in greatest diameter, and stages IA-IV. Users followed a standard operating procedure established at the Mayo Clinic, and were blinded to clinical characteristics and patient outcomes. Results: To measure inter-user variability of ADC voxel composition, the intraclass correlation coefficient (ICC) was calculated based upon the percentage of each voxel subtype within the whole ADC. An ICC of 1 reflects high reproducibility between users. Amongst all 50 ADCs, the average ICC for all nine voxel types was 0.828 (95% CI 0.76, 0.895). The ICC of the four voxel types associated with invasive features on CT was 0.865 (95% CI 0.805, 0.924). ICCs were also calculated using a logarithmic transformation for data normalization, generating an ICC of 0.745 (95% CI 0.663, 0.826) for all nine voxel types, and an ICC of 0.995 (95% CI 0.993, 0.997) for the four voxel types associated with invasion. Conclusions: (1) CANARY analysis of lung ADC voxel signatures appears to be reproducible amongst users, making it a reliable tool for the evaluation of ADC voxel density. (2) Correlation of invasive signatures associated with more aggressive ADCs was nearly perfect amongst users. Additional validation metrics for CANARY with larger datasets are being evaluated, including the accuracy of tumor prognostic predictions between users and analysis of ADC datasets from other institutions. Citation Format: Erica C. Nakajima, Michael P. Frankland, Tucker Johnson, Sanja L. Antic, Ronald A. Karwoski, Bennett Landman, Heidi Chen, Ronald C. Walker, Brian J. Bartholmai, Tobias Peikert, Srinivasan Rajagopalan, Pierre P. Massion, Fabien Maldonado. Assessing the reproducibility of computer-aided nodule assessment and risk yield (CANARY) method to characterize lung adenocarcinomas [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2017; 2017 Apr 1-5; Washington, DC. Philadelphia (PA): AACR; Cancer Res 2017;77(13 Suppl):Abstract nr 3723. doi:10.1158/1538-7445.AM2017-3723
Evaluation of visual and computer‐based CT analysis for the identification of functional patterns of obstruction and restriction in hypersensitivity pneumonitis

Respirology | July 12, 2017 | Volume: 22 | Issue: 8 | Pages: 1585-1591

10.1111/resp.13122 | PMID 28699237

ABSTRACTBackground and objectiveTo determine whether computer‐based quantification (CALIPER software) is superior to visual computed tomography (CT) scoring in the identification of CT patterns indicative of restrictive and obstructive functional indices in hypersensitivity pneumonitis (HP).MethodsA total of 135 consecutive HP patients had CT parenchymal patterns evaluated quantitatively by both visual scoring and CALIPER. Results were evaluated against: forced vital capacity (FVC), total lung capacity (TLC), diffusing capacity for carbon monoxide (DLCO) and a composite physiological index (CPI) to identify which CT scoring method better correlated with functional indices.ResultsCALIPER‐derived scores of total interstitial lung disease extent correlated more strongly than visual scores: FVC (CALIPER R = 0.73, visual R = 0.51); DLCO (CALIPER R = 0.61, visual R = 0.48); and CPI (CALIPER R = 0·70, visual R = 0·55). The CT variable that correlated most strongly with restrictive functional indices was CALIPER pulmonary vessel volume (PVV): FVC R = 0.75, DLCO R = 0.68 and CPI R = 0.76.Ground‐glass opacity quantified by CALIPER alone demonstrated strong associations with restrictive functional indices: CALIPER FVC R = 0.65; DLCO R = 0.59; CPI R = 0.64; and visual = not significant. Decreased attenuation lung quantified by CALIPER was a better morphological measure of obstructive lung disease than equivalent visual scores as judged by relationships with TLC (CALIPER R = 0.63 and visual R = 0.12). All results were maintained on multivariate analysis.ConclusionCALIPER improved on visual scoring in HP as judged by restrictive and obstructive functional correlations. Decreased attenuation regions of the lung quantified by CALIPER demonstrated better linkages to obstructive lung physiology than visually quantified CT scores. A novel CALIPER variable, the PVV, demonstrated the strongest linkages with restrictive functional indices and could represent a new automated index of disease severity in HP.
An ultrasound surface wave elastography technique for noninvasive measurement of surface lung tissue

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3721-3721

10.1121/1.4988149

Ultrasonography is not widely used in clinic for lung assessment because ultrasound cannot image deep lung tissue. In this abstract, we present a novel technique, lung ultrasound surface wave elastography (LUSWE), for measuring the elastic properties of superficial lung tissue. In LUSWE, a small, local, and 0.1 second harmonic vibration is generated on the chest of a subject. The speed of surface wave on the lung is measured by using an ultrasound probe. We are evaluating LUSWE for assessing patients with interstitial lung disease (ILD). LUSWE may be useful for assessing ILD because most ILD patients have typical fibrotic scars in the peripheral and subpleural regions of the lung. In a large clinical study of ILD patients, we measure both lungs through six intercostal spaces for patients and controls. The surface wave speed is measured at 100 Hz, 150 Hz, and 200 Hz. In an example, the surface wave speed is 1.88 ± 0.11 m/s and 3.3 ± 0.37 m/s, respectively, for a healthy subject and an ILD patient at 100 Hz and in the same intercostal space. LUSWE may compliment the clinical standard high-resolution computed tomography for assessing ILD. LUSWE may be useful for assessing other lung disorders.