Citations 49

Investigation of Squeaking in Pyrolytic Carbon Proximal Interphalangeal Joint Implants

Journal of Medical Devices | December 19, 2013 | Volume: 8 | Issue: 1 | Pages: No page available

10.1115/1.4026289

One commonly reported complication of pyrolytic carbon arthroplasty at the proximal interphalangeal (PIP) joint is an annoying, painless, squeaking postoperatively. This squeak has been anecdotally associated with implant loosening or impending dislocation. The purpose of this study was to investigate the etiology of this squeaking. Proximal and distal components of the pyrolytic carbon PIP implant were inserted into foam bones and mounted onto an oscillating test device. We evaluated the effect of 96 combinations of load, velocity, contact angle, implant size, lubrication, and displacement amplitude over a total of 300 cycles for each condition. Sound analysis was performed on squeaking conditions. Fourteen conditions resulted in squeaking, all with a sound pattern similar to that noted clinically. Unlubricated, “dry” joints did not squeak. Squeaking most commonly occurred with fetal bovine serum lubrication, at higher loads, and at 0 deg hyperextension. Hyaluronic acid viscosupplementation stopped the squeaking in all cases.
The effect of low‐ and high‐velocity tendon excursion on the mechanical properties of human cadaver subsynovial connective tissue

Journal of Orthopaedic Research | September 13, 2013 | Volume: 32 | Issue: 1 | Pages: 123-128

10.1002/jor.22489 | PMID 24038298

SUMMARYFibrosis of the subsynovial connective tissue (SSCT) in the carpal tunnel is the most common histological finding in carpal tunnel syndrome (CTS). Fibrosis may result from damaged SSCT. Previous studies found that with low‐velocity (2 mm/s), tendon excursions can irreversibly damage the SSCT. We investigated the effect of tendon excursion velocity in the generation of SSCT damage. Nine human cadaver wrists were used. Three repeated cycles of ramp‐stretch testing were performed simulating 40%, 60%, 90%, and 120% of the middle finger flexor tendon superficialis physiological excursion with an excursion velocity of 60 mm/s. Energy and force were calculated and normalized by values obtained in the first cycle for each excursion level. Data were compared with low‐velocity excursion data. For high‐velocity excursions, a significant drop in the excursion energy ratio was first observed at an excursion level of 60% physiological excursion (p < 0.024) and that for low‐velocity excursions was first observed at 90% physiological excursion (p < 0.038). Furthermore, the energy ratio was lower at 60% for high velocities (p ≤ 0.039). Increasing velocity lowers the SSCT damage threshold. This finding may be relevant for understanding the pathogenesis of SSCT fibrosis, such as that accompanying CTS, and a relationship with occupational factors. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:123–128, 2014.
Tendon gradient mineralization for tendon to bone interface integration

Journal of Orthopaedic Research | August 12, 2013 | Volume: 31 | Issue: 11 | Pages: 1713-1719

10.1002/jor.22412 | PMID 23939935

AbstractTendon‐to‐bone integration is a great challenge for tendon or ligament reconstruction regardless of use of autograft or allograft tendons. We mineralized the tendon, thus transforming the tendon‐to‐bone into a “bone‐to‐bone” interface for healing. Sixty dog flexor digitorum profundus (FDP) tendons were divided randomly into five groups: (1) normal FDP tendon, (2) CaP (non‐extraction and mineralization without fetuin), (3) CaPEXT (Extraction by Na2HPO4 and mineralization without fetuin), (4) CaPFetuin (non‐extraction and mineralization with fetuin), and (5) CaPEXTFetuin (extraction and mineralization with fetuin). The calcium and phosphate content significantly increased in tendons treated with combination of extraction and fetuin compared to the other treatments. Histology also revealed a dense mineral deposition throughout the tendon outer layers and penetrated into the tendon to a depth of 200 µm in a graded manner. Compressive moduli were significantly lower in the four mineralized groups compared with normal control group. No significant differences in maximum failure strength or stiffness were found in the suture pull‐out test among all groups. Mineralization of tendon alters the interface from tendon to bone into mineralized tendon to bone, which may facilitate tendon‐to‐bone junction healing following tendon or ligament reconstruction. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:1713–1719, 2013
Distal attachment of flexor tendon allograft: A biomechanical study of different reconstruction techniques in human cadaver hands

Journal of Orthopaedic Research | June 10, 2013 | Volume: 31 | Issue: 11 | Pages: 1720-1724

10.1002/jor.22403 | PMID 23754507

ABSTRACTWe compared the mechanical force of tendon‐to‐bone repair techniques for flexor tendon reconstruction. Thirty‐six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon‐to‐bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:1720–1724, 2013
Comparison of step-cut and Pulvertaft attachment for flexor tendon graft: a biomechanics evaluation in an in vitro canine model

Journal of Hand Surgery (European Volume) | April 4, 2012 | Volume: 37 | Issue: 9 | Pages: 848-854

10.1177/1753193412442460 | PMID 22490997

The purpose of this study was to compare two different methods of joining tendons of similar and dissimilar sizes between recipient and donor tendons for flexor tendon grafts. Flexor digitorum profundus (FDP) and peroneus longus (PL) canine tendons were harvested and divided into four groups. The repair technique we compared was a step-cut (SC) suture and a Pulvertaft weave (PW). FDP tendons were significantly larger in diameter than PL tendons ( p < 0.05). The volume of the SC repairs using either FDP or PL tendon as a graft was significantly smaller than PW repairs ( p < 0.05). The ultimate load to failure and repair stiffness in FDP graft tendons significantly increased compared with the PL graft tendons ( p < 0.05). The SC suture can be used as an alternative to the PW, with similar strength and less bulk for repairs using graft tendons of similar diameter. Surgeons should be aware of the effect of graft tendon size and repair method on strength and bulk when performing flexor tendon grafts.
Delta screw versus RetroScrew tibial fixation for ACL reconstruction

Knee Surgery, Sports Traumatology, Arthroscopy | May 17, 2011 | Volume: 19 | Issue: S1 | Pages: 94-100

10.1007/s00167-011-1543-8 | PMID 22080349

AbstractPurposeThe purpose of this study is to determine whether the RetroScrew tibial fixation system offers a biomechanical advantage over the Delta screw for anterior cruciate ligament (ACL) reconstruction in cadaveric tibias with low bone mineral density (BMD).MethodsTen matched pairs of osteoporotic cadaveric tibiae underwent simulated ACL reconstruction using quadrupled hamstring grafts with one of the two tibial fixation constructs. Group 1 was fixed with the Delta screw (DS; 35‐mm antegrade biointerference screw), and group 2 was fixed with the RetroScrew system (RSS; 20‐mm retrograde and 17‐mm antegrade biointerference screws). Each construct was cyclically loaded (50–200 N, 1 Hz, 500 cycles) and subsequently loaded to failure (20 mm/s).ResultsAll specimens were osteoporotic without significant segmental (proximal, middle, and distal) BMD differences between groups by quantitative computed tomography (P = n.s.). A trend was noted for more construct failures due to graft slippage in the DS group (n = 3) over the RSS group (n = 1). There were no significant differences in cyclic displacement (P = n.s.), maximum cyclic stiffness (P = n.s.), maximum load at failure (P = n.s.), or pullout stiffness (P = n.s.) between groups.ConclusionsIn an osteoporotic cadaveric model, there was no significant biomechanical advantage of the RetroScrew system versus the Delta screw for tibial fixation in soft tissue graft ACL reconstruction. However, a trend toward lower graft fixation failure to cyclic loading was noted with the RetroScrew system.Level of evidenceBiomechanical comparative study, Level II.
A biomechanical comparison of the Delta screw and RetroScrew tibial fixation on initial intra‐articular graft tension

Knee Surgery, Sports Traumatology, Arthroscopy | January 21, 2011 | Volume: 19 | Issue: 5 | Pages: 781-786

10.1007/s00167-010-1366-z | PMID 21258782

AbstractPurposeThe purpose of this study is to determine the effect of bioabsorbable interference screw (BIS) tibial fixation with the Delta screw (antegrade) and RetroScrew (retrograde) on initial (time zero) intra‐articular graft tension in soft tissue anterior cruciate ligament (ACL) reconstruction in a cadaveric model.MethodsTen matched pairs of cadaveric tibias received one of two tibial fixation constructs using quadrupled hamstring grafts, Delta screw (antegrade) or the RetroScrew (retrograde). Each specimen was mounted to the materials testing device with the displacement force vector in line with the tibial tunnel. The construct was pre‐tensioned (10–30 N, 0.1 Hz, 10 cycles), a baseline tension of 25 N was introduced, and the change in intra‐articular graft tension before and after screw insertion was recorded.ResultsSegmental (proximal, middle, distal) BMD was utilized to assess BMD using quantitative computed tomography (qCT). The Delta screw had a higher maximum insertion torque (P = 0.03) and exhibited a larger increase in intra‐articular graft tension as compared to the RetroScrew (38.3 ± 17.9 N, 7.6 N ± 14.4, P = 0.004), respectively. There were no significant correlations between intra‐articular graft tension increase to maximum insertion torque (P = NS) or corresponding segmental BMD (P = NS).ConclusionsDelta screw tibial fixation (antegrade) in soft tissue ACL reconstruction significantly increases the initial intra‐articular graft tension as compared to RetroScrew screw fixation (retrograde) in this cadaveric model. Delta screw (antegrade) tibial fixation may increase initial quadrupled hamstring graft intra‐articular tension with currently accepted insertion techniques.
Temporal response of canine flexor tendon to limb suspension

Journal of Applied Physiology | October 15, 2010 | Volume: 109 | Issue: 6 | Pages: 1762-1768

10.1152/japplphysiol.00051.2010 | PMID 20947711

Tendon disuse, or stress deprivation, frequently accompanies clinical disorders and treatments, yet the metabolism of tendons subject to stress deprivation has rarely been investigated systematically. The effects of stress deprivation on canine flexor tendon were investigated in this study. One adult canine forepaw was suspended for 21 or 42 days. Control forepaws were collected from dogs that had no intervention on their limbs and paws. The expression of collagen I and III was not significantly altered in the tendons disused for 21 days but was significantly decreased at 42 days ( P < 0.03). The expression of collagen II, aggrecan, decorin, and fibronectin was significantly decreased in the tendons in the suspended limbs at 21 days ( P < 0.002) and further reduced at 42 days. With stress deprivation, the expression of matrix metalloproteinase 2 (MMP2) was significantly increased ( P < 0.004) at 21 and 42 days. The expression of MMP3 was significantly decreased at 21 and 42 days ( P < 0.03). The expression of MMP13 was not altered with stress deprivation at 21 and 42 days. The expression of MMP14 was significantly increased at 21 days ( P = 0.0015) and returned to the control level at 42 days. Tissue inhibitor of metalloproteinase 1 (TIMP1) expression was decreased after the limbs were suspended for 42 days ( P = 0.0043), but not 21 days. However, TIMP2 expression was not significantly different from control at 21 or 42 days. Furthermore, the cross-sectional area of the stress-deprived tendons at 42 days was decreased compared with the control group ( P < 0.01). The intervention method in this study did not result in any alteration of stiffness of the tendon. Our study demonstrated that stress deprivation decreases the anabolic process and increases the catabolic process of extracellular matrix in flexor tendon.
Computer-Aided Design, Manufacturing, and Modeling of Polymer Scaffolds for Tissue Engineering

Manufacturing Engineering and Materials Handling, Parts A and B | April 3, 2008 | Volume: No volume available | Issue: No issue available | Pages: 169-174

10.1115/imece2005-81621

A custom computer-controlled rapid prototyping system was designed and developed in this research. This system for bio-manufacturing of polymer scaffolds included 3D motion control components, a nozzle, a pressure controller, and a temperature-controlled reservoir containing a biomaterial. Heating elements built into the reservoir melted the biomaterial. The pressure line attached to the reservoir provided a controllable force that extruded the polymer biomaterial through the nozzle and deposited the polymer biomaterial onto a platform to fabricate scaffolds. A low pressure (830 KPa) system was designed and fabricated to accommodate different temperatures, motion speeds, and viscosities of polymer biomaterials. The reservoir with the nozzle was mounted to servo motor-controlled linear x-y motion devices along with a third servo motor-controlled device that controlled the z-position of the platform. Poly(ε-caprolactone) [PCL] was used to fabricate scaffolds with designed structure that were used in cell and tissue regeneration studies. 3D computer-aided design (CAD) with Pro-Engineer and computational finite element analysis (FEA) programs with MSC_Patran and MSC_Marc were used to model scaffold designs with appropriate architecture and material selection. The CAD models were used in FEA to develop new methods for determining mechanical properties of tissue scaffolds of desired structure and geometry. FEA models were validated by mechanical testing and other published results. Technology developed in this research has potential for the advancement of bio-manufacturing, and design optimization of scaffolds for tissue engineering.