Improving Mechanical Properties of Tendon Allograft through Rehydration Strategies: An In Vitro Study

Bioengineering | May 25, 2023 | Volume: 10 | Issue: 6 | Pages: 641

10.3390/bioengineering10060641 | PMID 37370572

Allogenic tendons grafts sourced from intrasynovial tendons are often used for tendon reconstruction. Processing is achieved through repetitive freeze–thaw cycles followed by lyophilization. Soaking the lyophilized tendon in saline (0.9%) for 24 h is the standard practice for rehydration. However, data supporting saline rehydration over the use of other hydrating solutions are scant. The purpose of the current study was to compare the effects of different rehydration solutions on biomechanical properties of lyophilized tendon allograft. A total of 36 canine flexor digitorum profundus tendons were collected, five freeze–thaw cycles followed by lyophilization were performed for processing, and then divided into three groups rehydrated with either saline solution (0.9%), phosphate-buffered saline (PBS), or minimum essential medium (MEM). Flexural stiffness, tensile stiffness, and gliding friction were evaluated before and after allograft processing. The flexural moduli in both fibrous and fibrocartilaginous regions of the tendons were measured. After lyophilization and reconstitution, the flexural moduli of both the fibrocartilaginous and non-fibrocartilaginous regions of the tendons increase significantly in the saline and MEM groups (p < 0.05). Compared to the saline and MEM groups, the flexural moduli of the fibrocartilaginous and non-fibrocartilaginous regions of tendons rehydrated with PBS are significantly lower (p < 0.05). Tensile moduli of rehydrated tendons are significantly lower than those of fresh tendons for all groups (p < 0.05). The gliding friction of rehydrated tendons is significantly higher than that of fresh tendons in all groups (p < 0.05). There is no significant difference in either tensile moduli or gliding friction between tendons treated with different rehydration solutions. These results demonstrate that allograft reconstitution can be optimized through careful selection of hydrating solution and that PBS could be a better choice as the impact on flexural properties is lower.
The Effect of Pulling Angle on Rotator Cuff Mechanical Properties in a Canine In Vitro Model

Bioengineering | May 17, 2023 | Volume: 10 | Issue: 5 | Pages: 599

10.3390/bioengineering10050599 | PMID 37237669

The objective of this study was to examine the effect of pulling angle on time-zero mechanical properties of intact infraspinatus tendon or infraspinatus tendon repaired with the modified Mason-Allen technique in a canine model in vitro. Thirty-six canine shoulder samples were used. Twenty intact samples were randomly allocated into functional pull (135°) and anatomic pull (70°) groups (n = 10 per group). The remaining sixteen infraspinatus tendons were transected from the insertion and repaired using the modified Mason-Allen technique before being randomly allocated into functional pull or anatomic pull groups (n = 8 per group). Load to failure testing was performed on all specimens. The ultimate failure load and ultimate stress of the functional pulled intact tendons were significantly lower compared with anatomic pulled tendons (1310.2 ± 167.6 N vs. 1687.4 ± 228.2 N, p = 0.0005: 55.6 ± 8.4 MPa vs. 67.1 ± 13.3 MPa, p = 0.0334). For the tendons repaired with the modified Mason-Allen technique, no significant differences were observed in ultimate failure load, ultimate stress or stiffness between functional pull and anatomic pull groups. The variance of pulling angle had a significant influence on the biomechanical properties of the rotator cuff tendon in a canine shoulder model in vitro. Load to failure of the intact infraspinatus tendon was lower at the functional pulling position compared to the anatomic pulling position. This result indicates that uneven load distribution across tendon fibers under functional pull may predispose the tendon to tear. However, this mechanical character is not presented after rotator cuff repair using the modified Mason-Allen technique.
Evaluation of Scapholunate Injury and Repair with Dynamic (4D) CT: A Preliminary Report of Two Cases

Journal of Wrist Surgery | February 9, 2023 | Volume: 12 | Issue: 03 | Pages: 248-260

10.1055/s-0042-1758159 | PMID 37223378

Abstract Background In predynamic or dynamic scapholunate (SL) instability, standard diagnostic imaging may not identify SL interosseous ligament (SLIL) injury, leading to delayed detection and intervention. This study describes the use of four-dimensional computed tomography (4DCT) in identifying early SLIL injury and following injured wrists to 1-year postoperatively. Description of Technique 4DCT acquires a series of three-dimensional volume data with high temporal resolution (66 ms). 4DCT-derived arthrokinematic data can be used as biomarkers of ligament integrity. Patients and Methods This study presents the use of 4DCT in a two-participant case series to assess changes in arthrokinematics following unilateral SLIL injury preoperatively and 1-year postoperatively. Patients were treated with volar ligament repair with volar capsulodesis and arthroscopic dorsal capsulodesis. Arthrokinematics were compared between uninjured, preoperative injured, and postoperative injured (repaired) wrists. Results 4DCT detected changes in interosseous distances during flexion-extension and radioulnar deviation. Generally, radioscaphoid joint distances were greatest in the uninjured wrist during flexion-extension and radioulnar deviation, and SL interval distances were smallest in the uninjured wrist during flexion-extension and radioulnar deviation. Conclusion 4DCT provides insight into carpal arthrokinematics during motion. Distances between the radioscaphoid joint and SL interval can be displayed as proximity maps or as simplified descriptive statistics to facilitate comparisons between wrists and time points. These data offer insight into areas of concern for decreased interosseous distance and increased intercarpal diastasis. This method may allow surgeons to assess whether (1) injury can be visualized during motion, (2) surgery repaired the injury, and (3) surgery restored normal carpal motion. Level of Evidence Level IV, Case series.
Voluntary Modulation of Evoked Responses Generated by Epidural and Transcutaneous Spinal Stimulation in Humans with Spinal Cord Injury

Journal of Clinical Medicine | October 24, 2021 | Volume: 10 | Issue: 21 | Pages: 4898

10.3390/jcm10214898 | PMID 34768418

Transcutaneous (TSS) and epidural spinal stimulation (ESS) are electrophysiological techniques that have been used to investigate the interactions between exogenous electrical stimuli and spinal sensorimotor networks that integrate descending motor signals with afferent inputs from the periphery during motor tasks such as standing and stepping. Recently, pilot-phase clinical trials using ESS and TSS have demonstrated restoration of motor functions that were previously lost due to spinal cord injury (SCI). However, the spinal network interactions that occur in response to TSS or ESS pulses with spared descending connections across the site of SCI have yet to be characterized. Therefore, we examined the effects of delivering TSS or ESS pulses to the lumbosacral spinal cord in nine individuals with chronic SCI. During low-frequency stimulation, participants were instructed to relax or attempt maximum voluntary contraction to perform full leg flexion while supine. We observed similar lower-extremity neuromusculature activation during TSS and ESS when performed in the same participants while instructed to relax. Interestingly, when participants were instructed to attempt lower-extremity muscle contractions, both TSS- and ESS-evoked motor responses were significantly inhibited across all muscles. Participants with clinically complete SCI tested with ESS and participants with clinically incomplete SCI tested with TSS demonstrated greater ability to modulate evoked responses than participants with motor complete SCI tested with TSS, although this was not statistically significant due to a low number of subjects in each subgroup. These results suggest that descending commands combined with spinal stimulation may increase activity of inhibitory interneuronal circuitry within spinal sensorimotor networks in individuals with SCI, which may be relevant in the context of regaining functional motor outcomes.
A novel engineered purified exosome product patch for tendon healing: An explant in an ex vivo model

Journal of Orthopaedic Research | September 16, 2020 | Volume: 39 | Issue: 8 | Pages: 1825-1837

10.1002/jor.24859 | PMID 32936480

AbstractReducing tendon failure after repair remains a challenge due to its poor intrinsic healing ability. The purpose of this study is to investigate the effect of a novel tissue‐engineered purified exosome product (PEP) patch on tendon healing in a canine ex vivo model. Lacerated flexor digitorum profundus (FDP) tendons from three canines' paws underwent simulated repair with Tisseel patch alone or biopotentiated with PEP. For the ex vivo model, FDP tendons were randomly divided into three groups: FDP tendon repair alone group (Control), Tisseel patch alone group, and the Tisseel plus PEP (TEPEP) patch group. Following 4 weeks of tissue culture, the failure load, stiffness, histology, and gene expression of the healing tendon were evaluated. Transmission electron microscopy revealed that in exosomes of PEP the diameters ranged from 93.70 to 124.65 nm, and the patch release test showed this TEPEP patch could stably release the extracellular vesicle over 2 weeks. The failure strength of the tendon in the TEPEP patch group was significantly higher than that of the Control group and Tisseel alone group. The results of histology showed that the TEPEP patch group had the smallest healing gap and the largest number of fibroblasts on the surface of the injured tendon. Quantitative reverse transcription polymerase chain reaction showed that TEPEP patch increased the expression of collagen type III, matrix metallopeptidase 2 (MMP2), MMP3, MMP14, and reduced the expression of transforming growth factor β1, interleukin 6. This study shows that the TEPEP patch could promote tendon repair by reducing gap formation and inflammatory response, increasing the activity of endogenous cells, and formation of type III collagen.
Biomechanical evaluation of a novel double rip-stop technique with medial row knots for rotator cuff repair

Bone & Joint Research | June 16, 2020 | Volume: 9 | Issue: 6 | Pages: 285-292

10.1302/2046-3758.96.bjr-2019-0196.r1 | PMID 32728429

AimsMany biomechanical studies have shown that the weakest biomechanical point of a rotator cuff repair is the suture-tendon interface at the medial row. We developed a novel double rip-stop (DRS) technique to enhance the strength at the medial row for rotator cuff repair. The objective of this study was to evaluate the biomechanical properties of the DRS technique with the conventional suture-bridge (SB) technique and to evaluate the biomechanical performance of the DRS technique with medial row knots.MethodsA total of 24 fresh-frozen porcine shoulders were used. The infraspinatus tendons were sharply dissected and randomly repaired by one of three techniques: SB repair (SB group), DRS repair (DRS group), and DRS with medial row knots repair (DRSK group). Specimens were tested to failure. In addition, 3 mm gap formation was measured and ultimate failure load, stiffness, and failure modes were recorded.ResultsThe mean load to create a 3 mm gap formation in the DRSK and DRS groups was significantly higher than in the SB group. The DRSK group had the highest load to failure with a mean ultimate failure load of 395.0 N (SD 56.8) compared to the SB and DRS groups, which recorded 147.1 N (SD 34.3) and 285.9 N (SD 89.8), respectively (p < 0.001 for both). The DRS group showed a significantly higher mean failure load than the SB group (p = 0.006). Both the DRS and DRSK groups showed significantly higher mean stiffness than the SB group.ConclusionThe biomechanical properties of the DRS technique were significantly improved compared to the SB technique. The DRS technique with medial row knots showed superior biomechanical performance than the DRS technique alone.
Accelerated osteocyte senescence and skeletal fragility in mice with type 2 diabetes

JCI Insight | April 8, 2020 | Volume: 5 | Issue: 9 | Pages: No page available

10.1172/jci.insight.135236 | PMID 32267250

The worldwide prevalence of type 2 diabetes (T2D) is increasing. Despite normal to higher bone density, patients with T2D paradoxically have elevated fracture risk resulting, in part, from poor bone quality. Advanced glycation endproducts (AGEs) and inflammation as a consequence of enhanced receptor for AGE (RAGE) signaling are hypothesized culprits, although the exact mechanisms underlying skeletal dysfunction in T2D are unclear. Lack of inducible models that permit environmental (in obesity) and temporal (after skeletal maturity) control of T2D onset has hampered progress. Here, we show in C57BL/6 mice that a onetime pharmacological intervention (streptozotocin, STZ) initiated in adulthood combined with high-fat diet–induced (HFD-induced) obesity caused hallmark features of human adult-onset T2D, including prolonged hyperglycemia, insulin resistance, and pancreatic β cell dysfunction, but not complete destruction. In addition, HFD/STZ (i.e., T2D) resulted in several changes in bone quality that closely mirror those observed in humans, including compromised bone microarchitecture, reduced biomechanical strength, impaired bone material properties, altered bone turnover, and elevated levels of the AGE CML in bone and blood. Furthermore, T2D led to the premature accumulation of senescent osteocytes with a unique proinflammatory signature. These findings highlight the RAGE pathway and senescent cells as potential targets to treat diabetic skeletal fragility.
Shear wave elastography of the median nerve: A mechanical study

Muscle & Nerve | March 14, 2020 | Volume: 61 | Issue: 6 | Pages: 826-833

10.1002/mus.26863 | PMID 32170959

AbstractBackgroundShear wave elastography (SWE) shows promise in peripheral neuropathy evaluation but has potential limitations due to tissue size and heterogeneity. We tested SWE sensitivity to elasticity change and the effect of probe position in a median nerve cadaver model.MethodsTen specimens were used to measure median nerve elasticity under increasing loads using SWE and indentation. Measurements were compared using repeated‐measures analysis of variance.ResultsIndentation and SWE‐based longitudinal nerve elasticity increased with tensile loading (P< .01), showing a similar relationship. Acquisition in a transverse plane showed lower values compared with longitudinal measurements, mostly under higher loads (P= .03), as did postdissection elasticity (P= .02). Elasticity did not change when measured proximal to the carpal tunnel.ConclusionsLongitudinal SWE is sensitive to changes in median nerve elasticity. Measuring elasticity of peripheral nerves noninvasively could elucidate intra‐neural pathology related to compression neuropathies, and proof to be of added value as a diagnostic or prognostic tool.
Human synoviocyte lubricin and bovine synovial fluid lubricin equally improve gliding resistance in a canine model in vitro

Bio-Medical Materials and Engineering | December 2, 2019 | Volume: 21 | Issue: 5-6 | Pages: 281-289

10.3233/bme-2012-0676 | PMID 22561248

Effect of the location of the split of the subscapularis on range of motion and stability of the glenohumeral joint following Latarjet or Trillat procedures

Orthopaedic Journal of Sports Medicine | May 30, 2019 | Volume: 7 | Issue: 5_suppl3 | Pages: No page available

10.1177/2325967119s00202

Aim: Compare the effect of Latarjet and Trillat procedures on glenohumeral stability and range of motion. Background: Little is known about the impact of the location of the sling effect on joint stability and range of motion. Methods: 12 cadaveric shoulders were cleaned of soft tissue except for the subscapularis, conjoined tendon, and anterior capsule. A custom-made apparatus generating anterior humeral translation and joint compression was used. The machine applied compression load in the medial direction. The subscapularis and conjoint tendon were loaded. Internal/external range of motion and joint stability were assessed at 0°, 30° and 60° glenohumeral abduction. Range of motion was assessed by rotating the humeral shaft. Joint stability was assessed at maximum external rotation, translating the humerus. Specimen were tested in five conditions: 1) intact shoulder, 2) 6-mm bony glenoid defect (20% defect) 3) Trillat procedure, 4) Latarjet procedure with subscapularis split at the junction between its superior 2/3rds and inferior 1/3 rd, 5) Latarjet procedure with subscapularis split at the superior 1/3rds and inferior 2/3rds. Means were compared with a full factorial-repeated measures ANOVA with pairwise post hoc comparisons. Results: Peak translation force and stability ratio were significantly lower with the glenoid defect when compared to the intact and all the repaired conditions at all levels of glenohumeral abduction. The level of the subscapularis split had no significant influence on these values and no significant difference could be found between Trillat and Latarjet procedures. Range of motion in internal and external rotation were not significantly different between the different conditions. Conclusions: Joint stability and range of motion after a Latarjet are not impacted by the location of the subscapularis muscle split. Trillat and Latarjet techniques provide comparable stabilization of the joint, even in the presence of a critical bony defect of the glenoid.