Back to Authors

Deeb, G. Michael

https://orcid.org/0000-0002-4698-2789

A5028606740 | I27837315

Mayo Clinic

Department of Cardiac Surgery (G.M.D.)

Citations 8

Genome and Transcriptome-Wide Analyses Identify Multiple Candidate Genes and a Significant Polygenic Contribution in Bicuspid Aortic Valve

Circulation | February 6, 2026 | Volume: 153 | Issue: 14 | Pages: 1060-1076

10.1161/circulationaha.125.074752 | PMID 41645906

BACKGROUND: Bicuspid aortic valve (BAV) is a frequent congenital heart defect with a high heritability. Despite this, only a limited number of genes have been associated with the disease, and the molecular mechanisms remain unexplained in most cases. This study aimed to further understand the genetic architecture of BAV. METHODS: A genome-wide association study meta-analysis including 9631 cases among 65 677 participants was performed. Genes were prioritized using transcriptomic analyses based on RNA sequencing in relevant tissues, including human fetal and adult aortic valves. The impact of the knockdown or knockout of 4 candidate genes on cardiac development was verified in zebrafish. A polygenic risk score was developed, its association with BAV was evaluated in an independent cohort, and its association with a wide range of phenotypes (n=976) was evaluated in UK Biobank (n=355 618 individuals). RESULTS: Thirty-six genomic loci were identified, including 32 that were not described previously. Among the prioritized genes, KANK2 and ERBB4 were identified as potentially causal through transcriptomic analyses, colocalization, and Mendelian randomization based on gene expression in human aortic valves (n=484), whereas PRDM6 and STRN were prioritized using similar analyses from aortic (n=326) and left ventricular tissues (n=326), respectively. Targeting 4 candidate genes ( WNT4 , LEF1 , STRN , and KANK2 ) in zebrafish led to disruption in cardiac development. A polygenic risk score was associated with an odds ratio of 2.07 (95% CI, 1.90–2.25; P =5.43×10 -62 ) per SD for BAV and significantly associated with thoracic aortic aneurysm and atrial fibrillation in UK Biobank. CONCLUSIONS: This study supports a significant polygenic contribution to BAV, where the combination of multiple common variants in genes involved in heart morphogenesis disrupts aortic valve development.
Three-Year Outcomes Following TAVR in Younger (

Circulation: Cardiovascular Interventions | October 18, 2024 | Volume: 17 | Issue: 11 | Pages: No page available

10.1161/circinterventions.124.014018 | PMID 39421943

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis, but data are limited on younger, low-risk patients. This analysis compares outcomes in low-surgical-risk patients aged <75 years receiving TAVR versus surgery. METHODS: The Evolut Low Risk Trial randomized 1414 low-risk patients to treatment with a supra-annular, self-expanding TAVR or surgery. We compared rates of all-cause mortality or disabling stroke, associated clinical outcomes, and bioprosthetic valve performance at 3 years between TAVR and surgery patients aged <75 years. RESULTS: In patients <75 years, 352 were randomized to TAVR and 351 to surgery. Mean age was 69.1±4.0 years (minimum 51 and maximum 74); Society of Thoracic Surgeons Predicted Risk of Mortality was 1.7±0.6%. At 3 years, all-cause mortality or disabling stroke for TAVR was 5.7% and 8.0% for surgery ( P =0.241). Although there was no difference between TAVR and surgery in all-cause mortality, the incidence of disabling stroke was lower with TAVR (0.6%) than surgery (2.9%; P =0.019), while surgery was associated with a lower incidence of pacemaker implantation (7.1%) compared with TAVR (21.0%; P <0.001). Valve reintervention rates (TAVR 1.5%, surgery 1.5%, P =0.962) were low in both groups. Valve performance was significantly better with TAVR than surgery with lower mean aortic gradients ( P <0.001) and lower rates of severe prosthesis-patient mismatch ( P <0.001). Rates of valve thrombosis and endocarditis were similar between groups. There were no significant differences in rates of residual ≥moderate paravalvular regurgitation. CONCLUSIONS: Low-risk patients <75 years treated with supra-annular, self-expanding TAVR had comparable 3-year all-cause mortality and lower disabling stroke compared with patients treated with surgery. There was significantly better valve performance in patients treated with TAVR. REGISTRATION: URL: https://clinicaltrials.gov ; Unique identifier: NCT02701283.
Examining the typical hemodynamic performance of nearly 3000 modern surgical aortic bioprostheses

European Journal of Cardio-Thoracic Surgery | May 7, 2024 | Volume: 65 | Issue: 5 | Pages: No page available

10.1093/ejcts/ezae122 | PMID 38710669

Abstract OBJECTIVES The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. Clinical trial registration number NCT02088554, NCT02701283, NCT01586910 and NCT01531374.
Structural Valve Deterioration After Self-Expanding Transcatheter or Surgical Aortic Valve Implantation in Patients at Intermediate or High Risk

JAMA Cardiology | December 14, 2022 | Volume: 8 | Issue: 2 | Pages: 111

10.1001/jamacardio.2022.4627 | PMID 36515976

ImportanceThe frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood.ObjectiveTo evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery.Design, Setting, and ParticipantsThis post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022.InterventionsPatients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies.Main Outcomes and MeasuresThe primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more.ResultsOf 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P &amp;lt; .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis.Conclusions and RelevanceThis study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes.Trial RegistrationClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients

JAMA Cardiology | August 24, 2022 | Volume: 7 | Issue: 10 | Pages: 1000

10.1001/jamacardio.2022.2695 | PMID 36001335

Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P &amp;lt; .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P &amp;lt; .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P &amp;lt; .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis

JAMA Cardiology | October 7, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1001/jamacardio.2020.4738 | PMID 33031491

Computed Tomography–Based Indexed Aortic Annulus Size to Predict Prosthesis-Patient Mismatch

Circulation: Cardiovascular Interventions | April 1, 2019 | Volume: 12 | Issue: 4 | Pages: No page available

10.1161/circinterventions.118.007396 | PMID 30929507

Background: Hemodynamic performance of prostheses after transcatheter aortic valve replacement (TAVR) is generally better than after surgical aortic valve replacement (SAVR), especially in patients with a small native annulus size. However, it remains unclear whether differences are consistent for patients with a different propensity for developing prosthesis-patient mismatch (PPM), considering annulus size and body size of patients. Methods and Results: The SURTAVI trial (Surgical Replacement and Transcatheter Aortic Implantation) compared TAVR using a self-expandable valve with SAVR in intermediate-risk patients. Multidetector computed tomography–based aortic annulus size consisted of the perimeter-derived diameter, which was divided by body surface area to produce an indexed annulus size. Patients were categorized into a small (9–12 mm/m 2 ), medium (>12–14 mm/m 2 ), and large (>14–18 mm/m 2 ) group according to indexed annulus size. We compared TAVR and SAVR for PPM, hemodynamics, and clinical, and functional outcomes through 1-year follow-up within the size groups. Patients who underwent TAVR received a larger prosthesis with increasing indexed annulus size ( P <0.001), while there was no difference in prosthesis size in patients who underwent SAVR ( P =0.74). Patients in all size groups had significantly larger indexed effective orifice area and lower mean gradients at discharge after TAVR versus SAVR. Rates of PPM were significantly lower with TAVR versus SAVR in all groups ( P <0.001) and declined with larger indexed annulus sizes with both TAVR ( P =0.04) and SAVR ( P =0.03). Indexed annulus size was an independent predictor of PPM after TAVR and SAVR. Clinical outcomes were comparable between TAVR and SAVR across all groups, apart from a significantly higher rate of reintervention after TAVR versus SAVR in the large indexed annulus size group (2.5% versus 0%; P =0.01) but without significant interaction ( P int =0.81). Conclusions: Rates of PPM were significantly lower after TAVR than after SAVR across all groups of indexed annulus size, reflecting better hemodynamic performance of transcatheter versus surgical valves, irrespective of the propensity to develop PPM. More attention should be directed to prevention of PPM after SAVR. This information should be considered by the Heart Team to recommend a specific procedure or valve. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01586910.
Outcomes in the Randomized CoreValve US Pivotal High Risk Trial in Patients With a Society of Thoracic Surgeons Risk Score of 7% or Less

JAMA Cardiology | August 19, 2016 | Volume: 1 | Issue: 8 | Pages: 945

10.1001/jamacardio.2016.2257 | PMID 27541162