Citations 9

Diffusion-Tensor MRI at 3 T: Differentiation of Central Gland Prostate Cancer From Benign Prostatic Hyperplasia

American Journal of Roentgenology | February 20, 2014 | Volume: 202 | Issue: 3 | Pages: W254-W262

10.2214/ajr.13.11015 | PMID 24555622

Diffusion-Weighted Magnetic Resonance Imaging for the Evaluation of Prostate Cancer: Optimal B Value at 3T

Korean Journal of Radiology | January 7, 2013 | Volume: 14 | Issue: 1 | Pages: 61

10.3348/kjr.2013.14.1.61 | PMID 23323032

Evaluation of Transplanted Kidneys Using Blood Oxygenation Level–Dependent MRI at 3 T: A Preliminary Study

American Journal of Roentgenology | April 23, 2012 | Volume: 198 | Issue: 5 | Pages: 1108-1114

10.2214/ajr.11.7253 | PMID 22528900

Utility of Iodine Overlay Technique and Virtual Unenhanced Images for the Characterization of Renal Masses by Dual-Energy CT

American Journal of Roentgenology | November 22, 2011 | Volume: 197 | Issue: 6 | Pages: W1076-W1082

10.2214/ajr.11.6922 | PMID 22109322

Assessment of Renal Lesions With Blood Oxygenation Level–Dependent MRI at 3 T: Preliminary Experience

American Journal of Roentgenology | August 23, 2011 | Volume: 197 | Issue: 3 | Pages: W489-W494

10.2214/ajr.10.6319 | PMID 21862777

MR staging accuracy for endometrial cancer based on the new FIGO stage

Acta Radiologica | July 8, 2011 | Volume: 52 | Issue: 7 | Pages: 818-824

10.1258/ar.2011.100426 | PMID 21742787

Background Magnetic resonance imaging (MRI) has been frequently used to determine a preoperative treatment plan for gynecologic cancers. However, the MR accuracy for staging an endometrial cancer is not satisfactory based on the old FIGO staging system. Purpose To evaluate MR accuracy for staging endometrial cancer using the new FIGO staging system. Material and Methods Between January 2005 and May 2009, 199 women underwent surgery due to endometrial cancer. In each patient, an endometrial cancer was staged using MR findings based on the old FIGO staging system and then repeated according to the new FIGO staging system for comparison. Histopathologic findings were used as a standard of reference. Results The accuracy of MRI in the staging of endometrial carcinoma stage I, II, III, and IV using the old FIGO staging system were 80% (159/199), 89% (178/199), 90% (179/199), and 99% (198/199), respectively, compared to 87% (174/199), 97% (193/199), 90% (179/199), and 99% (198/199), respectively, when using the new FIGO staging criteria. The overall MR accuracy of the old and new staging systems were 51% (101/199) and 81% (161/199), respectively. Conclusion MRI has become a more useful tool in the preoperative staging of endometrial cancers using the new FIGO staging system compared to the old one with increased accuracy.
Diffusion-Weighted MRI at 3 T for the Evaluation of Prostate Cancer

American Journal of Roentgenology | May 20, 2010 | Volume: 194 | Issue: 6 | Pages: 1461-1469

10.2214/ajr.09.3654 | PMID 20489084

High-b-Value Diffusion-Weighted Imaging at 3 T to Detect Prostate Cancer: Comparisons Between b Values of 1,000 and 2,000 s/mm2

American Journal of Roentgenology | December 22, 2009 | Volume: 194 | Issue: 1 | Pages: W33-W37

10.2214/ajr.09.3004 | PMID 20028888

Isolated tubal torsion: specific signs on preoperative computed tomography and magnetic resonance imaging

Acta Radiologica | February 26, 2008 | Volume: 49 | Issue: 2 | Pages: 233-235

10.1080/02841850701687292 | PMID 18300152

Isolated torsion of the fallopian tube is a rare cause of lower abdominal pain and commonly occurs after menarche. Prompt identification of this entity can prevent irreversible vascular damage, but the diagnosis is rarely made before surgery due to nonspecific clinical and imaging features. We report a case of isolated tubal torsion with specific imaging features on preoperative computed tomography and magnetic resonance imaging.