Citations 36

Clinical acceptance testing and scanner comparison of ultrasound shear wave elastography

Journal of Applied Clinical Medical Physics | March 15, 2018 | Volume: 19 | Issue: 3 | Pages: 336-342

10.1002/acm2.12310 | PMID 29542277

AbstractBecause of the rapidly growing use of ultrasound shear wave elastography (SWE) in clinical practices, there is a significant need for development of clinical physics performance assessment methods for this technology. This study aims to report two clinical medical physicists’ tasks: (a) acceptance testing (AT) of SWE function on ten commercial ultrasound systems for clinical liver application and (b) comparison of SWE measurements of targets across vendors for clinical musculoskeletal application. For AT, ten GE LOGIQ E9 XDclear 2.0 scanners with ten C1‐6‐D and ten 9L‐D transducers were studied using two commercial homogenous phantoms. Five measurements were acquired at two depths for each scanner/transducer pair by two operators. Additional tests were performed to access effects of different coupling media, phantom locations and operators. System deviations were less than 5% of group mean or three times standard deviation; therefore, all systems passed AT. A test protocol was provided based on results that no statistically significant difference was observed between using ultrasound gel and salt water for coupling, among different phantom locations, and that interoperator and intraoperator coefficient of variation was less than 3%. For SWE target measurements, two systems were compared — a Supersonic Aixplorer scanner with a SL10‐2 and a SL15‐4 transducer, and an abovementioned GE scanner with 9L‐D transducer. Two stepped cylinders with diameters of 4.05–10.40 mm were measured both longitudinally and transaxially. Target shear wave speed quantification was performed using an in‐house MATLAB program. Using the target shear wave speed deduced from phantom specs as a reference, SL15‐4 performed the best at the measured depth. However, it was challenging to reliably measure a 4.05 mm target for either system. The reported test methods and results could provide important information when dealing with SWE‐related tasks in the clinical environment.
Is axillary surgery beneficial for patients with adenoid cystic carcinoma of the breast?

Journal of Surgical Oncology | June 13, 2017 | Volume: 116 | Issue: 6 | Pages: 690-695

10.1002/jso.24702 | PMID 28608456

Background and ObjectivesAdenoid cystic carcinoma (ACC) is a rare, typically triple‐negative, breast cancer reported to have a favorable prognosis and low rate of nodal metastasis. No consensus guidelines exist for axillary staging and treatment.MethodsWe identified all patients with ACC evaluated at our institution from January 1994 to August 2016. Patient, tumor, and treatment variables were abstracted and analyzed.ResultsWe identified 20 pure ACCs (0.13% of all invasive breast cancers) with size range 0.2‐4.8 cm, in 19 women, median age 59 years. Preoperative axillary ultrasound was normal in 10/13 women and suspicious in 3/13 who had a subsequent negative lymph node fine needle aspiration (FNA). Fifteen patients (75%) had sentinel lymph node surgery and were pathologically node‐negative, while the remaining five had no axillary surgery. With 3.6 years median follow‐up (range 0.2‐38.6 years), three patients experienced an in‐breast recurrence at 2, 16, and 17 years, respectively, while none recurred in regional nodes.ConclusionsWe observed no cases of nodal metastasis in 20 consecutive cases of ACC of the breast. Preoperative axillary ultrasound with FNA of suspicious nodes accurately predicted pathologic nodal stage. These data suggest axillary surgery might be omitted safely in patients with pure ACC and a clinically negative axilla.
Second-look axillary ultrasound after breast MRI for enhanced preoperative nodal staging in newly diagnosed breast cancer patients.

Journal of Clinical Oncology | February 24, 2017 | Volume: 31 | Issue: 26_suppl | Pages: 98-98

10.1200/jco.2013.31.26_suppl.98

98 Background: Concomitant with widespread adoption of axillary ultrasound (AUS) with ultrasound-guided needle biopsy (USNB) of suspicious lymph nodes (LN) for preoperative nodal staging of breast cancer patients, utilization of breast MRI, which includes axillary imaging, has increased. Little is known about the added value of MRI imaging of the axilla in this context. We undertook this study to assess the role of breast MRI in preoperative axillary nodal staging. Methods: We studied 988 consecutive invasive breast cancers in patients undergoing primary operation including axillary surgery, without neoadjuvant therapy, from 2010-2011. Results: 505 patients (51%) underwent MRI of which 168 (33%) demonstrated suspicious findings in the axilla. Abnormal axillary MRI findings included cortical thickening, edema, enhancement, hilar effacement, and/or altered shape and size. 114 patients had findings concordant with AUS. 54 patients had suspicious LNs on MRI either without a preceding AUS (33 cases) or after an initially negative AUS (21 cases). Second look AUS was performed in 29 of these cases and was abnormal in 3 (10%) in whom USNB confirmed metastatic adenopathy. Of the 54 cases with MRI-detected suspicious LNs 20 (37%) were node positive at operation with a pN stage of N0 (63%), N0i+ (5%), N1mic (4%), N1 (20%), N2 (6%), N3 (2%); extranodal extension was seen in 7 of 20 node-positive patients (35%). Conclusions: Second look AUS, when performed secondary to suspicious axillary MRI findings, identified LN metastasis preoperatively in 10% of patients. When MRI is done to evaluate the breast in newly diagnosed breast cancer patients, axillary findings can enhance the accuracy of preoperative nodal staging. We recommend second look AUS when MRI demonstrates suspicious axillary LN findings. [Table: see text]
Dual-Energy CT for Evaluation of Intra- and Extracapsular Silicone Implant Rupture

Case Reports in Radiology | January 28, 2016 | Volume: 2016 | Issue: No issue available | Pages: 1-4

10.1155/2016/6323709 | PMID 26942031

Silicone implants are commonly used for both breast augmentation and breast reconstruction. With aging of the implant, the silicone envelope may become weak or may rupture. The technique of choice for evaluation of implant integrity is breast MRI; however this may be contraindicated in some patients or the cost may be prohibitive. Dual-energy CT allows determination of density and atomic number of tissue and can provide material composition information. We present a case of extracapsular implant rupture with MRI and dual-energy CT imaging and surgical correlation.
Abstract P1-01-03: Value of breast MRI for preoperative axillary assessment of breast cancer patients

Cancer Research | May 4, 2015 | Volume: 75 | Issue: 9_Supplement | Pages: P1-01-03-P1-01-03

10.1158/1538-7445.sabcs14-p1-01-03

Abstract Background: Many newly diagnosed breast cancer patients undergo preoperative breast MRI which includes visualization of some degree of the axilla. The impact of patient characteristics and tumor biology on the fidelity of MRI imaging of the axilla in these cases is not well-studied. We sought to examine the correlation between nodal findings on breast MRI and pathologic nodal status in newly diagnosed breast cancer patients. Methods: With IRB approval, we identified 1868 consecutive breasts with invasive cancer in 1803 patients undergoing primary operation with axillary surgery from 1/2010-7/2013. Patients undergoing neoadjuvant chemotherapy (348) were excluded leaving 1510 breasts with cancer in 1455 patients. Preoperative MRI was performed in 763 patients (52%). We evaluated patient, imaging and pathology data. Results: Patients evaluated with MRI were median age 57 years. The majority of tumors were T1 (63%) and T2 (28%). MRI identified suspicious axillary nodes in 240 cases (31%), of which 123 (51%) were node positive at operation. Suspicious axillary findings on MRI predicted both nodal status and pN stage at operation (both p<0.0001). The sensitivity, specificity, accuracy, positive (PPV) and negative predictive value (NPV) of MRI for nodal disease across tumor types is shown. Pathologic Node PositiveSensitivity (95% CI)Specificity (95% CI)NPV (95% CI)PPV (95% CI)Accuracy (95% CI)All Cases (n=763)234 (31%)52.6 (46-59.1)77.9 (74.1-81.3)78.8 (75-82.1)51.3 (44.8-57.7)70.1 (66.7-73.3)Approximated Biologic Subtype (missing=24)ER+/HER2- (n=609)194 (32%)51.0 (43.8-58.2)80.0 (75.8-83.7)77.8 (73.4-81.5)54.4 (46.9-61.7)70.8 (67-74.3)HER2+ (n=69)20 (29%)65.0 (40.9-83.7)71.4 (56.5-83)83.3 (68-92.5)48.1 (29.2-67.6)69.6 (57.2-79.8)ER-/HER2- (n=61)17 (28%)58.8 (33.5-80.6)75.0 (59.4-86.3)82.5 (66.6-92.1)47.6 (26.4-70)70.5 (57.3-81.1)p value0.740.430.330.560.730.98Tumor Grade (missing=5)1 (n=259)58 (22%)32.8 (21.4-46.5)79.6 (73.2-84.8)80.4 (74.1-85.5)31.7 (20.6-45.1)69.1 (63.0-74.6)2 (n=351)124 (35%)55.6 (46.5-64.5)79.7 (73.8-84.6)76.7 (70.7-81.8)60.0 (50.4-68.9)71.2 (66.1-75.9)3 (n=148)51 (34%)66.7 (52.0-79.0)70.1 (59.8-78.8)80.0 (69.6-87.6)54.0 (41.0-66.4)68.9 (60.7-76.1)p value0.0010.00030.110.720.020.93 Diagnostic performance did not vary significantly based on patient body mass index (BMI) or approximated biologic subtype, but specificity was better for patients >age 50 (p=0.007) and sensitivity and PPV both were worse for grade 1 vs grade 2/3 tumors. Node positivity rate at operation was 48% (51/106) for patients with a solitary abnormal node on MRI and 54% (72/134) when >1 suspicious node was seen (p=0.39). However, multiple vs solitary MRI suspicious nodes correlated with ≥3 positive nodes at operation (40 [30%] vs 19 [18%], p=0.03) and pN2/pN3 disease (29 [22%] vs 12 [11%], p=0.03). Conclusion: Axillary lymph node findings on MRI for breast cancer predict nodal status and disease volume in invasive breast cancer patients. Tumor biologic subtype did not affect performance characteristics of preoperative MRI, but tumor grade did influence the sensitivity and PPV of MRI. When MRI is performed in the evaluation of newly diagnosed breast cancer, axillary findings inform pathologic nodal stage at operation regardless of tumor subtype. Citation Format: Sean C Dupont, Judy C Boughey, Tanya L Hoskin, Katrina N Glazebrook, Tina J Hieken. Value of breast MRI for preoperative axillary assessment of breast cancer patients [abstract]. In: Proceedings of the Thirty-Seventh Annual CTRC-AACR San Antonio Breast Cancer Symposium: 2014 Dec 9-13; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2015;75(9 Suppl):Abstract nr P1-01-03.
Ultrasound of Primary Aneurysmal Bone Cyst

Case Reports in Radiology | January 23, 2014 | Volume: 2014 | Issue: No issue available | Pages: 1-4

10.1155/2014/101069 | PMID 24587935

Aneurysmal bone cysts (ABC) are rare, benign, expansile lesions of bone often found in the metaphyses of long bones in pediatric and young adult population. Multiple fluid levels are typically seen on imaging with magnetic resonance imaging (MRI) or computed tomography (CT). We describe a case of a primary ABC in the fibula of a 34-year-old man diagnosed on ultrasound with a mobile fluid level demonstrated sonographically.
Sparganosis Presenting as a Mammographic Abnormality

The Breast Journal | November 18, 2013 | Volume: 20 | Issue: 1 | Pages: 92-94

10.1111/tbj.12211 | PMID 24237609

Pure Lobular Carcinoma of the Breast Presenting as a Hyperechoic Mass: Incidence and Imaging Characteristics

American Journal of Roentgenology | October 22, 2013 | Volume: 201 | Issue: 5 | Pages: W765-W769

10.2214/ajr.12.9742 | PMID 24147507

Advanced Imaging in Gout

American Journal of Roentgenology | August 23, 2013 | Volume: 201 | Issue: 3 | Pages: 515-525

10.2214/ajr.13.10776 | PMID 23971443

Vascular Tumors of the Breast: Mammographic, Sonographic, and MRI Appearances

American Journal of Roentgenology | February 28, 2013 | Volume: 184 | Issue: 1 | Pages: 331-338

10.2214/ajr.184.1.01840331 | PMID 15615997