Citations 38

Incidence and clinical outcomes of perforations during mechanical thrombectomy for medium vessel occlusion in acute ischemic stroke: A retrospective, multicenter, and multinational study

European Stroke Journal | February 27, 2024 | Volume: 9 | Issue: 2 | Pages: 328-337

10.1177/23969873231219412 | PMID 38409796

Abstract Background: Mechanical thrombectomy (MT) has revolutionized the treatment of acute ischemic stroke (AIS) due to large vessel occlusion (LVO), but its efficacy and safety in medium vessel occlusion (MeVO) remain less explored. This multicenter, retrospective study aims to investigate the incidence and clinical outcomes of vessel perforations (confirmed by extravasation during an angiographic series) during MT for AIS caused by MeVO. Methods: Data were collected from 37 academic centers across North America, Asia, and Europe between September 2017 and July 2021. A total of 1373 AIS patients with MeVO underwent MT. Baseline characteristics, procedural details, and clinical outcomes were analyzed. Results: The incidence of vessel perforation was 4.8% (66/1373). Notably, our analysis indicates variations in perforation rates across different arterial segments: 8.9% in M3 segments, 4.3% in M2 segments, and 8.3% in A2 segments (p = 0.612). Patients with perforation had significantly worse outcomes, with lower rates of favorable angiographic outcomes (TICI 2c-3: 23% vs 58.9%, p < 0.001; TICI 2b-3: 56.5% vs 88.3%, p < 0.001). Functional outcomes were also worse in the perforation group (mRS 0–1 at 3 months: 22.7% vs 36.6%, p = 0.031; mRS 0–2 at 3 months: 28.8% vs 53.9%, p < 0.001). Mortality was higher in the perforation group (30.3% vs 16.8%, p = 0.008). Conclusion: This study reveals that while the occurrence of vessel perforation in MT for AIS due to MeVO is relatively rare, it is associated with poor functional outcomes and higher mortality. The findings highlight the need for increased caution and specialized training in performing MT for MeVO. Further prospective research is required for risk mitigation strategies.
First pass effect as an independent predictor of functional outcomes in medium vessel occlusions: An analysis of an international multicenter study

European Stroke Journal | October 27, 2023 | Volume: 9 | Issue: 1 | Pages: 114-123

10.1177/23969873231208276 | PMID 37885243

Abstract Introduction: First pass effect (FPE), achievement of complete recanalization (mTICI 2c/3) with a single pass, is a significant predictor of favorable outcomes for endovascular treatment (EVT) in large vessel occlusion stroke (LVO). However, data concerning the impact on functional outcomes and predictors of FPE in medium vessel occlusions (MeVO) are scarce. Patients and Methods: We conducted an international retrospective study on MeVO cases. Multivariable logistic modeling was used to establish independent predictors of FPE. Clinical and safety outcomes were compared between the two study groups (FPE vs non-FPE) using logistic regression models. Good outcome was defined as modified Rankin Scale 0–2 at 3 months. Results: Eight hundred thirty-six patients with a final mTICI ⩾ 2b were included in this analysis. FPE was observed in 302 patients (36.1%). In multivariable analysis, hypertension (aOR 1.55, 95% CI 1.10–2.20) and lower baseline NIHSS score (aOR 0.95, 95% CI 0.93–0.97) were independently associated with an FPE. Good outcomes were more common in the FPE versus non-FPE group (72.8% vs 52.8%), and FPE was independently associated with favorable outcome (aOR 2.20, 95% CI 1.59–3.05). 90-day mortality and intracranial hemorrhage (ICH) were significantly lower in the FPE group, 0.43 (95% CI, 0.25–0.72) and 0.55 (95% CI, 0.39–0.77), respectively. Conclusion: Over 2/3 of patients with MeVOs and FPE in our cohort had a favorable outcome at 90 days. FPE is independently associated with favorable outcomes, it may reduce the risk of any intracranial hemorrhage, and 3-month mortality.
Stent-assisted Woven EndoBridge device for the treatment of intracranial aneurysms: an international multicenter study

Journal of Neurosurgery | October 21, 2023 | Volume: 140 | Issue: 4 | Pages: 1071-1079

10.3171/2023.8.jns235 | PMID 37862717

OBJECTIVE The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.
Aspiration Versus Stent‐Retriever as First‐Line Endovascular Therapy Technique for Primary Medium and Distal Intracranial Occlusions: A Propensity‐Score Matched Multicenter Analysis

Stroke: Vascular and Interventional Neurology | July 6, 2023 | Volume: 3 | Issue: 6 | Pages: No page available

10.1161/svin.123.000931 | PMID 41585056

Background For acute proximal intracranial artery occlusions, contact aspiration may be more effective than stent‐retriever for first‐line reperfusion therapy. Due to the lack of data regarding medium vessel occlusion thrombectomy, we evaluated outcomes according to first‐line technique in a large, multicenter registry. Methods Imaging, procedural, and clinical outcomes of patients with acute proximal medium vessel occlusions (M2, A1, or P1) or distal medium vessel occlusions (M3, A2, P2, or further) treated at 37 sites in 10 countries were analyzed according to first‐line endovascular technique (stent‐retriever versus aspiration). Multivariable logistic regression and propensity‐score matching were used to estimate the odds of the primary outcome, expanded Thrombolysis in Cerebral Infarction score of 2b–3 (“successful recanalization”), as well as secondary outcomes (first‐pass effect, expanded Thrombolysis in Cerebral Infarction 2c‐3, intracerebral hemorrhage, and 90‐day modified Rankin scale, 90‐day mortality) between treatment groups. Results Of the 440 included patients (44.5% stent‐retriever versus 55.5% aspiration), those treated with stent‐retriever had lower baseline Alberta Stroke Program Early Computed Tomography Scale scores (median 8 versus 9; P <0.01), higher National Institutes of Health Stroke Scale scores (median 13 versus 11; P =0.02), and nonsignificantly fewer medium‐distal occlusions (M3, A2, P2, or other: 17.4% versus 23.8%; P =0.10). Use of a stent‐retriever was associated with 15% lower odds of successful recanalization (odds ratio [OR], 0.85; [95% CI 0.74–0.98]; P =0.02), but this was not significant after multivariable adjustment in the total cohort (adjusted OR, 0.88; [95% CI 0.72–1.09]; P =0.24), or in the propensity‐score matched cohort (n=105 in each group) (adjusted OR, 0.94; [95% CI 0.75–1.18]; P =0.60). There was no significant association between technique and secondary outcomes in the propensity‐score matched adjusted models. Conclusion In this large, diverse, multinational medium vessel occlusion cohort, we found no significant difference in imaging or clinical outcomes with aspiration versus stent‐retriever thrombectomy.
Intrasaccular flow disruption for ruptured aneurysms: an international multicenter study

Journal of NeuroInterventional Surgery | July 22, 2022 | Volume: 15 | Issue: 9 | Pages: 844-850

10.1136/jnis-2022-019153 | PMID 35868856

Background The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. Methods Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. Results The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. Conclusion There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.
Flow Diversion for Middle Cerebral Artery Aneurysms: An International Cohort Study

Neurosurgery | September 8, 2021 | Volume: 89 | Issue: 6 | Pages: 1112-1121

10.1093/neuros/nyab365 | PMID 34624100

Abstract BACKGROUND Open surgery has traditionally been preferred for the management of bifurcation middle cerebral artery (MCA) aneurysms. Flow diverting stents present a novel endovascular strategy for aneurysm treatment. OBJECTIVE To add to the limited literature describing the outcomes and complications in the use of flow diverters for the treatment of these complex aneurysms. METHODS This is a multicenter retrospective review of MCA bifurcation aneurysms undergoing flow diversion. We assessed post-treatment radiological outcomes and both thromboembolic and hemorrhagic complications. RESULTS We reviewed the outcomes of 54 aneurysms treated with flow diversion. Four (7.4%) of the aneurysms had a history of rupture (3 remote and 1 acute). Fourteen (25.9%) of the aneurysms already underwent either open surgery or coiling prior to flow diversion. A total of 36 out of the 45 aneurysms (80%) with available follow-up data had adequate aneurysm occlusion with a median follow-up time of 12 mo. There were no hemorrhagic complications but 16.7% (9/54) had thromboembolic complications. CONCLUSION Flow diverting stents may be a viable option for the endovascular treatment of complex bifurcation MCA aneurysms. However, compared to published series on the open surgical treatment of this subset of aneurysms, flow diversion has inferior outcomes and are associated with a higher rate of complications.
Comparison of PED and FRED flow diverters for posterior circulation aneurysms: a propensity score matched cohort study

Journal of NeuroInterventional Surgery | July 1, 2020 | Volume: 13 | Issue: 2 | Pages: 153-158

10.1136/neurintsurg-2020-016055 | PMID 32611622

Abstract Background Flow diversion is a common endovascular treatment for cerebral aneurysms, but studies comparing different types of flow diverters are scarce. Objective To perform a propensity score matched cohort study comparing the Pipeline Embolization Device (PED) and Flow Redirection Intraluminal Device (FRED) for posterior circulation aneurysms. Methods Consecutive aneurysms of the posterior circulation treated at 25 neurovascular centers with either PED or FRED were collected. Propensity score matching was used to control for age, duration of follow-up imaging, adjunctive coiling, and aneurysm location, size, and morphology; previously ruptured aneurysms were excluded. The two devices were compared for the following outcomes: procedural complications, aneurysm occlusion, and functional outcome. Results A total of 375 aneurysms of the posterior circulation were treated in 369 patients. The PED was used in 285 (77.2%) and FRED in 84 (22.8%) procedures. Aneurysms treated with the PED were more commonly fusiform and larger than those treated with FRED. To account for these important differences, propensity score matching was performed resulting in 33 PED and FRED unruptured aneurysm pairs. No differences were found in occlusion status and neurologic thromboembolic or hemorrhagic complications between the two devices. The proportion of patients with favorable functional outcome was higher with FRED (100% vs 87.9%, p=0.04). Conclusion Comparative analysis of PED and FRED for the treatment of unruptured posterior circulation aneurysms did not identify significant differences in aneurysm occlusion or neurologic complications. Variations in functional outcomes warrant additional investigations.
Experience With the Pipeline Embolization Device for Posterior Circulations Aneurysms: A Multicenter Cohort Study

Neurosurgery | June 5, 2020 | Volume: 87 | Issue: 6 | Pages: 1252-1261

10.1093/neuros/nyaa277 | PMID 32629474

Abstract BACKGROUND The Pipeline Embolization Device (PED; Medtronic) has been used off-label for the treatment of challenging posterior circulation aneurysms. Data on this modality are primarily limited to small retrospective single-center series. OBJECTIVE To assess safety and efficacy of this treatment by establishing an international, multicenter collaboration. METHODS Consecutive posterior circulation aneurysms treated with the PED from 2012 to 2019 across 11 neurovascular centers were retrospectively reviewed. Baseline demographics, aneurysm and treatment characteristics, complications, occlusion status, and functional outcome were assessed. RESULTS There were 149 posterior circulation aneurysms treated with PED in 146 patients. A total of 24 (16.4%) patients presented with subarachnoid hemorrhage. Most aneurysms were dissecting/blister (36.2%) in morphology, followed by saccular (35.6%) and fusiform (28.2%). The most common locations were the vertebral (51.7%) and basilar arteries (22.8%). Complete or near-complete occlusion (>90%) was achieved in 90.9% of aneurysms at a median follow-up of 12 mo. Dissecting/blister aneurysms were most likely to occlude ( P = .06). Symptomatic neurologic complications occurred in 9.4% of aneurysms, associated with larger size, ruptured presentation, presentations with brain stem compression, cranial nerve palsy, or stroke. Favorable functional outcome (modified Rankin Score 0-2) was achieved in 86.2% of patients. There were 6 fatalities of which 4 occurred in aneurysmal subarachnoid hemorrhage patients. CONCLUSION This multicenter study shows that PED for the treatment of posterior circulation is preferentially used for the treatment of fusiform and dissecting/blister aneurysm morphologies. Despite the challenges presented by these less-common morphologies, flow diversion may be performed with a neurologic complication rate of about 10% and favorable long-term aneurysm occlusion rates.