Abstract 4135872: Effects of In-vivo Contact Force on Pulsed Field Ablation Lesion Size in Porcine Ventricles

Circulation | November 13, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4135872

Background: Pulsed field ablation (PFA) is an innovative modality for treating arrhythmias that is mostly non-thermal and renders myocardial tissue non-viable by creating pores in cardiac cell membranes. The impact of contact force (CF) on PFA efficacy is not well characterized. Hypothesis: We hypothesize that, while contact is necessary for PFA, increasing CF will not have a significant effect on in vivo ablation lesion size. Aim: We seek to investigate the effects of CF on acute PFA lesions in a beating porcine heart model. Methods: The ventricles of 7 porcine animals were ablated in vivo with PFA (500V, at 20μs for 50 pulses separated by 200ms) using a focal bipolar irrigated ablation catheter and BTX 830 electroporation generator (Harvard Apparatus). CF was measured before and after each PFA application using CARTO 3. Lesions were divided into standard CF (5-15g), high CF (16-30g), and very high CF (>31g). Results: A total of 46 lesions were analyzed. Gross pathology showed no significant difference in maximum width, lesion depth, and lesion volume between the three groups ( Figure 1A-B ). Linear regression showed a decrease of 0.003 mm in depth (depth = -0.003 × CF + 1.8, R = 0.05), an increase of 0.01 mm in width (width = 0.01 × CF + 5.7, R = 0.09), and a decrease of 0.05 mm 3 in volume (volume = -0.05 × CF + 26.8, R = 0.03) for each additional gram of CF ( Figure 1C ). Conclusion: While contact is necessary, increasing CF did not have a significant effect on in-vivo PFA lesion dimensions in a beating porcine heart model.
Abstract 4135869: Local Ethanol Infusion after Pulsed Field Ablation Enhances Acute Efficacy of In Vivo Ventricular Electroporation

Circulation | November 13, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4135869

Background: Pulsed field ablation (PFA) has emerged as an innovative technology for treating cardiac arrhythmias. PFA increases cell permeability, which can lead to apoptosis. Greater PFA energy may be necessary to ablate ventricular myocardium for ventricular tachycardia circuits, but this carries risks of side effects such as gaseous formation (microbubbles) and hemolysis. Ethanol (EtOH) infusion has been used to ablate pathologic myocardial tissues in hypertrophic cardiomyopathy and for refractory arrhythmias. Hypothesis: We hypothesize that PFA in the ventricle can increase EtOH uptake through PFA-generated pores, thereby enhancing ablation efficacy, even at low powers, by utilizing the cell permeability effects of PFA. Aim: The aim of this study is to investigate the effect of local EtOH infusion after PFA on lesion size in porcine ventricles. Methods: The ventricles of five porcine subjects were ablated in vivo with a PFA low power setting (750 V, at 20 μs for 50 pulses separated by 200 ms) using a focal bipolar irrigated ablation catheter and BTX 830 electroporation generator (Harvard Apparatus). After PFA was performed, 2 ml of 90 % EtOH vs. saline (control) was infused through the catheter tip to the site of ablation. We compared the electrograms voltage amplitude reduction before and after PFA, and the ablation lesion characteristics. Results: A total of 10 lesions in the control group and 9 lesions in the EtOH group were analyzed. For the controls, the voltage after PFA was not reduced. In contrast, for the EtOH group, the voltage after PFA was significantly reduced ( Figure 1A ). On gross pathology, there were significant differences in ablation lesion depths and volumes between the 2 lesion sets ( Figure 1A-B ). Conclusion: Local EtOH infusion after ventricular PFA enhanced acute efficacy of electroporation. Concurrent PFA with local EtOH infusion has the potential to improve efficacy without requiring higher energy parameters, thereby reducing PFA risks. Future studies on chronic efficacy are warranted.
Abstract 4134594: More than One Way to Catch a Fish: Micra Extraction Case Series

Circulation | November 13, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4134594

Description of Cases: Case 1: A 72 year old male with atrial fibrillation (AF) and tachy-brady syndrome underwent Micra implantation. On post-procedure day 2, pacing thresholds were unacceptably elevated. A new Micra device was deployed; subsequently, a microsnare was placed through the Micra delivery catheter and the docking button of the old Micra was successfully snared (Figure A). The old Micra was then captured over the delivery catheter and removed from the body. Case 2: A 76 year old male underwent Micra implantation and AV node ablation for AF with persistent tachycardia. One month later, he presented with heart failure and interval decrease in ejection fraction from 66% to 33%. After biventricular leads were implanted, an Agilis catheter was advanced towards the Micra. The docking button was successfully snared with a gooseneck snare (Figure B), and the Micra was extracted with gentle traction. Case 3: A 76 year old male with complete heart block and longstanding persistent AF received a Micra. Nine months later, he presented with heart failure and interval decrease in ejection fraction from 55% to 25%. A defibrillator lead was implanted but no suitable CS branch was identified. The Aveir retrieval catheter was advanced and the Micra docking button was captured with the triloop snare (Figure C). The protective sleeve was advanced over the Micra and it was successfully removed. Subsequently, a left bundle area lead was placed. Discussion: Although uncommon, extraction of the tined leadless pacemaker (Micra) may be indicated at times. As rates of implantation continue to increase, establishing uniform procedures for extraction becomes increasingly important. These three cases highlight unique options for Micra extraction, and the feasibility of each approach. However, a dedicated tool and protocol would be ideal for patient safety and consistency. No complications occurred with the above cases.
Abstract 4136926: Premature Ventricular Complexes and Nonsustained Ventricular Tachycardia in Cardiac Sarcoidosis

Circulation | November 11, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4136926

Introduction: The prevalence and prognostic significance of PVC and NSVT in cardiac sarcoidosis (CS), especially in patients with normal or mildly decreased LV function, are not well known and were investigated in the current study. Methods: We included 192 patients with definite and probable CS with LVEF>35%, no prior history of VT/VF or sudden cardiac death, who underwent up to 48 hours of Holter monitoring. They were followed retrospectively for the composite endpoint of sustained VT/VF, advanced heart failure therapy, and all-cause mortality. We performed multivariable analysis for the association of PVC burden and NSVT with the composite endpoint. Covariates were considered if they were present in at least 95% of the study sample and were significantly associated with the composite endpoint in univariable analysis. Results: The median PVC burden in the overall population was 0.3% (IQR 0.02-2.5%) and 36 (18.8%) patients had a PVC burden ≥5%. Sixty-two (32.3%) patients had NSVT detected during monitoring. The PVC burden and prevalence of NSVT in patient subgroups are shown in Figures 1 and 2. A total of 33 (17.2%) patients experienced one of the composite endpoints at a median follow-up of 3 years. In the multivariable analysis (Figure 3), PVC burden ≥5% versus <5% (HR 3.96 [1.19, 5.97], p-value <0.01) and presence of NSVT (HR 4.55 [2.09, 9.94], p-value <0.01) were associated with the composite outcome. Conclusion: Our results suggest that a high PVC burden and the presence of NSVT carry isolated prognostic value in CS. In addition, ventricular ectopy does not appear to be an indicator of disease activity based on abnormal uptake on PET scan.
Abstract 4114716: Concurrent Ethanol Infusion with Pulsed Field Ablation Augments Electroporation of Porcine Atria

Circulation | November 11, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4114716

Background: Pulsed field ablation (PFA) is a promising modality for treatment of cardiac arrhythmias. PFA increases cell permeability, thereby promoting cell apoptosis. Although greater PFA energy may produce larger lesions, it also carries risks of side effects such as arcing, hemolysis, and microbubbles. Chemical ablation using ethanol (EtOH), such as with injection of the Vein of Marshall, has been used to treat atrial myocardium for refractory atrial arrhythmias. Hypothesis: We hypothesize that PFA in the atria can increase EtOH uptake through PFA-generated pores, thereby augmenting ablation efficacy by utilizing the cell permeability effects of PFA. Aim: The aim of this study is to investigate the effects of local EtOH infusion after PFA on lesion size in porcine atria. Methods: The atria of five porcine subjects were ablated in vivo with low PFA power settings (250V, at 20μs for 50 pulses separated by 200 ms) using a focal bipolar irrigated ablation catheter and BTX 830 electroporation generator (Harvard Apparatus). After PFA, 2 ml of 90 % EtOH vs. saline (control) was infused through the catheter tip to the site of ablation. We compared electrogram voltage amplitude reduction and ablation lesion parameters before and after PFA. Results: A total of 14 control lesions and 14 EtOH lesions were analyzed. There was significant difference in voltage reduction between two groups ( Figure 1A-B ). On gross pathology, there were significant differences in ablation lesion maximum surface diameter, lesion depth, and volume between the 2 lesion sets ( Figure 1C ). Conclusion: Concurrent EtOH infusion after PFA enhanced acute efficacy of electroporation in porcine atria. Adjuvant therapy has the potential to improve efficacy without requiring higher energy parameters, thereby reducing PFA risks. Further studies to assess chronic efficacy are warranted.
Detection of Right and Left Ventricular Dysfunction in Pediatric Patients Using Artificial Intelligence–Enabled ECGs

Journal of the American Heart Association | November 4, 2024 | Volume: 13 | Issue: 21 | Pages: No page available

10.1161/jaha.124.035201 | PMID 39494568

Background Early detection of left and right ventricular systolic dysfunction (LVSD and RVSD respectively) in children can lead to intervention to reduce morbidity and death. Existing artificial intelligence algorithms can identify LVSD and RVSD in adults using a 12‐lead ECG; however, its efficacy in children is uncertain. We aimed to develop novel artificial intelligence–enabled ECG algorithms for LVSD and RVSD detection in pediatric patients. Methods and Results We identified 10 142 unique pediatric patients (age≤18) with a 10‐second, 12‐lead surface ECG within 14 days of a transthoracic echocardiogram, performed between 2002 and 2022. LVSD was defined quantitatively by left ventricular ejection fraction (LVEF). RVSD was defined semiquantitatively. Novel pediatric models for LVEF ≤35% and LVEF <50% achieved excellent test areas under the curve of 0.93 (95% CI, 0.89–0.98) and 0.88 (95% CI, 0.83–0.94) respectively. The model to detect LVEF <50% had a sensitivity of 0.85, specificity of 0.80, positive predictive value of 0.095, and negative predictive value of 0.995. In comparison, the previously validated adult data‐derived model for LVEF <35% achieved an area under the curve of 0.87 (95% CI, 0.84–0.90) for LVEF ≤35% in children. A novel pediatric model for any RVSD detection reached a test area under the curve of 0.90 (0.87–0.94). Conclusions An artificial intelligence–enabled ECG demonstrates accurate detection of both LVSD and RVSD in pediatric patients. While adult‐trained models offer good performance, improvements are seen when training pediatric‐specific models.
Artificial intelligence-enabled electrocardiogram for left ventricular diastolic dysfunction and long-term risk of new-onset atrial fibrillation

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.469

Abstract Background Heart failure (HF) and atrial fibrillation (AF) are intertwined, sharing common risk factors and influencing each other in a reciprocal manner. While left ventricular diastolic dysfunction (LVDD) stands as a hallmark of HF's hemodynamic profile, its direct correlation with heightened AF risk remains uncertain. Our recent validation of an artificial intelligence-enabled electrocardiogram (AI-ECG) algorithm for LVDD detection has opened new avenues. Yet, whether AI-ECG-detected LVDD correlates with long-term AF risk remains unexplored. Methods We performed a retrospective study among all patients with a comprehensive LVDD assessment from the test population of the AI-ECG LVDD study between September 2001 and June 2022. Patients with prior documented AF according to health records or previous ECG were excluded. Patients were classified by AI-ECG as normal diastolic function (DF), grade 1 (G1), grade 2 (G2), or grade 3 (G3) LVDD. We assessed the risk of AF across AI-ECG LVDD grade, with normal DF as reference, with competing risk models. Results Of 97,023 patients free of AF at baseline, 63,533 (65.4%), 10,776 (11.1%), 18,940 (19.5%), and 3,774 (3.9%) were classified as normal DF, G1-LVDD, G2-LVDD, and G3-LVDD, respectively. Worse AI-ECG LVDD was associated with older age, lower left ventricular ejection fraction (LVEF), and higher rates of HF, diabetes, hypertension, chronic pulmonary disease, renal failure, and cardiovascular disease (p-of-trend&lt;0.001 for all). Over a median follow-up of 4.8 years (interquartile range 1.8-9.2 years), new-onset AF occurred in 6,795 (7.0%) patients. In multivariable survival analysis, adjusted to multiple risk factors including LVEF and clinical HF, G2 and G3 LVDD, representing patients with high filling pressures, were independently associated with a higher AF-risk [G2-LVDD: adjusted hazard ratio (aHR) 1.64 (95% confidence interval (95%CI) 1.52-1.73), G3-LVDD: aHR 2.24 (95%CI 2.02-2.48)]. Conclusion The AI-ECG LVDD algorithm independently predicts long-term AF risk, regardless of LVEF and clinical HF status, highlighting its potential for identifying high-risk populations and guiding proactive monitoring and management.
Local calcium chloride infusion after pulsed field ablation enhances acute efficacy of cardiac electroporation

Journal of Cardiovascular Electrophysiology | October 4, 2024 | Volume: 35 | Issue: 12 | Pages: 2354-2360

10.1111/jce.16439 | PMID 39363431

AbstractIntroductionPulsed field ablation (PFA) has emerged as an innovative therapy for cardiac arrhythmias. Drawing parallels with PFA's application in solid tumors, calcium chloride (CaCl2) as an adjuvant therapy, known as calcium electroporation, may amplify PFA's apoptotic effects. We propose that PFA in the atrium could enhance calcium uptake through PFA‐created pores, thereby increasing ablation efficacy even at reduced power levels by exploiting PFA's permeabilization effects.MethodsWe conducted in vivo ablations on the atria of seven pigs using low PFA power (250 V, 20 μs for 50 pulses at 200 ms intervals). Post‐PFA, we randomly administered an infusion of either 200 mg/2 ml CaCl2 (calcium group) or saline (control) directly to the ablation site via the catheter tip. We evaluated reduction in electrogram voltage amplitude, electrocardiography (ECG) parameters, ablation lesion parameters, and histology after PFA.ResultsNineteen lesions from control and calcium groups were examined. Control lesions showed no voltage decrease post‐PFA, whereas calcium‐treated lesions exhibited a significant voltage reduction. Gross pathology indicated marked differences in maximum lesion surface diameter, depth, and volume between the lesion groups. Histologically, calcium group lesions were characterized by a more severe acute PFA response with contraction band necrosis, myocytolysis and nuclear pyknosis in adjacent myocardium, in addition to microhemorrhages.ConclusionInfusing calcium chloride locally after PFA markedly improves the immediate efficacy of electroporation in porcine atria. This study suggests that calcium electroporation could bolster PFA outcomes without higher energy levels, potentially diminishing associated risks. These preliminary findings warrant further research into the long‐term efficacy and potential clinical application of calcium electroporation in PFA.
Pulsed Field Ablation: A Comprehensive Update

Journal of Clinical Medicine | September 2, 2024 | Volume: 13 | Issue: 17 | Pages: 5191

10.3390/jcm13175191 | PMID 39274404

One of the recent advancements in the field of cardiac electrophysiology is pulsed field ablation (PFA). PFA is a novel energy modality that does not rely on thermal processes to achieve ablation which, in turn, results in limited collateral damage to surrounding structures. In this review, we discuss the mechanisms, safety, efficacy, and clinical applications of PFA for the management of atrial and ventricular arrhythmias. We also summarize the published pre-clinical and clinical studies regarding this new technology.
Direct Comparison of Methods to Differentiate Wide Complex Tachycardias: Novel Automated Algorithms Versus Manual ECG Interpretation Approaches

Circulation: Arrhythmia and Electrophysiology | July 25, 2024 | Volume: 17 | Issue: 8 | Pages: No page available

10.1161/circep.123.012663 | PMID 39051111

BACKGROUND: Differentiating wide complex tachycardias (WCTs) into ventricular tachycardia (VT) and supraventricular wide tachycardia via 12-lead ECG interpretation is a crucial but difficult task. Automated algorithms show promise as alternatives to manual ECG interpretation, but direct comparison of their diagnostic performance has not been undertaken. METHODS: Two electrophysiologists applied 3 manual WCT differentiation approaches (ie, Brugada, Vereckei aVR, and VT score). Simultaneously, computerized data from paired WCT and baseline ECGs were processed by 5 automated WCT differentiation algorithms (WCT Formula, WCT Formula II, VT Prediction Model, Solo Model, and Paired Model). The diagnostic performance of automated algorithms was compared with manual ECG interpretation approaches. RESULTS: A total of 212 WCTs (111 VT and 101 supraventricular wide tachycardia) from 104 patients were analyzed. WCT Formula demonstrated superior accuracy (85.8%) and specificity (87.1%) compared with Brugada (75.2% and 57.4%, respectively) and Vereckei aVR (65.3% and 36.4%, respectively). WCT Formula II achieved higher accuracy (89.6%) and specificity (85.1%) against Brugada and Vereckei aVR. Performance metrics of the WCT Formula (accuracy 85.8%, sensitivity 84.7%, and specificity 87.1%) and WCT Formula II (accuracy 89.8%, sensitivity 89.6%, and specificity 85.1%) were similar to the VT score (accuracy 84.4%, sensitivity 93.8%, and specificity 74.2%). Paired Model was superior to Brugada in accuracy (89.6% versus 75.2%), specificity (97.0% versus 57.4%), and F1 score (0.89 versus 0.80). Paired Model surpassed Vereckei aVR in accuracy (89.6% versus 65.3%), specificity (97.0% versus 75.2%), and F1 score (0.89 versus 0.74). Paired Model demonstrated similar accuracy (89.6% versus 84.4%), inferior sensitivity (79.3% versus 93.8%), but superior specificity (97.0% versus 74.2%) to the VT score. Solo Model and VT Prediction Model accuracy (82.5% and 77.4%, respectively) was superior to the Vereckei aVR (65.3%) but similar to Brugada (75.2%) and the VT score (84.4%). CONCLUSIONS: Automated WCT differentiation algorithms demonstrated favorable diagnostic performance compared with traditional manual ECG interpretation approaches.