Citations 335

Troubleshooting Implanted Cardioverter Defibrillator Sensing Problems I

Circulation: Arrhythmia and Electrophysiology | December 16, 2014 | Volume: 7 | Issue: 6 | Pages: 1237-1261

10.1161/circep.114.002344 | PMID 25516582

The Challenges of Trigger Ablation for Ventricular Fibrillation

Journal of Cardiovascular Electrophysiology | December 2, 2014 | Volume: 26 | Issue: 1 | Pages: 116-117

10.1111/jce.12593 | PMID 25454834

Electrophysiologic Characteristics of Ventricular Arrhythmias Arising from the Aortic Mitral Continuity—Potential Role of the Conduction System

Journal of Cardiovascular Electrophysiology | November 26, 2014 | Volume: 26 | Issue: 2 | Pages: 158-163

10.1111/jce.12587 | PMID 25425429

Arrhythmogenic Substrate of Ventricular Arrhythmias at the AMCIntroductionCatheter ablation of ventricular arrhythmia (VA) at the fibrous aortic mitral continuity (AMC) has been described, yet the nature of the arrhythmogenic substrate remains unknown.MethodsProcedural records of 528 consecutive patients undergoing ablation of VA at Mayo Clinic, Rochester, MN, were reviewed. The electrocardiographic and electrophysiologic characteristics of patients with successful ablation at the AMC were analyzed to characterize the underlying arrhythmogenic substrate.ResultsOf the 21 patients (mean age 53.2 ± 13.4 years, 47.6% male) who underwent ablation of VA at the AMC with acute success, prepotentials (PPs) were found at the ablation sites preceding the ventricular electrogram (VEGM) during arrhythmias in 13 (61.9%) patients and during sinus rhythm in 7 (53.8%) patients. VAs with PPs were associated with a significantly higher burden of premature ventricular complexes (PVCs; 26.1 ± 10.9% vs. 14.9 ± 10.1%, P = 0.03), shorter VEGM to QRS intervals (9.0 ± 28.5 milliseconds vs. 33.1 ± 8.8 milliseconds, P = 0.03), lower pace map scores (8.7 ± 1.6 vs. 11.4 ± 0.8, P = 0.001), and a trend toward shorter V‐H intervals during VA (32.1 ± 38.6 milliseconds vs. 76.3 ± 11.1 milliseconds, P = 0.06) as compared to those without PP. A strong and positive correlation was found between V‐H interval and QRS duration during arrhythmia in those with PPs (B = 2.11, R2 = 0.97, t = 13.7, P < 0.001) but not in those without PPs.ConclusionLocal EGM characteristics and relative activation time of the His bundle suggest the possibility of conduction tissue as the origin for VA arising from the fibrous AMC. Specific identification and targeting of PPs when ablating VAs at this location may improve procedural success.
Ventricular Arrhythmia Risk Stratification in Patients With Tetralogy of Fallot at the Time of Pulmonary Valve Replacement

Circulation: Arrhythmia and Electrophysiology | November 21, 2014 | Volume: 8 | Issue: 1 | Pages: 110-116

10.1161/circep.114.001975 | PMID 25416756

Background— Most patients with repaired tetralogy of Fallot require pulmonary valve replacement (PVR), but the evaluation for and management of ventricular arrhythmia remain unclear. This study is aimed at clarifying the optimal approach to this potentially life-threatening issue at the time of PVR. Methods and Results— A retrospective analysis was performed on 205 patients with repaired tetralogy of Fallot undergoing PVR at our institution between 1988 and 2010. Median age was 32.9 (range, 25.6) years. Previous ventricular tachycardia occurred in 16 patients (8%) and 37 (16%) had left ventricular dysfunction, defined as left ventricular ejection fraction <50%. Surgical right ventricular outflow tract cryoablation was performed in 22 patients (10.7%). The primary outcome was a combined event including ventricular tachycardia, out-of-hospital cardiac arrest, appropriate implantable cardioverter defibrillator therapy, and sudden cardiac death. Freedom from the combined event at 5, 10, and 15 years was 95%, 90%, and 79%, respectively. In the first year after PVR, 2 events occurred. Conversely, in the 22 patients who underwent surgical cryoablation, a single event occurred 7 years after PVR. A history of ventricular tachycardia and left ventricular dysfunction was associated with higher risk for the combined event (hazard ratio, 4.7; P =0.004 and hazard ratio, 0.8; P =0.02, respectively). Conclusions— Patients with repaired tetralogy of Fallot undergoing PVR with history of ventricular tachycardia or left ventricular dysfunction appear to be associated with a higher risk of arrhythmic events after operation. Events in the first year after PVR are rare, and in select high-risk patients, surgical cryoablation does not seem to increase arrhythmic events and may be protective.
Maintaining Contact for Effective Mapping and Ablation

Circulation: Arrhythmia and Electrophysiology | October 21, 2014 | Volume: 7 | Issue: 5 | Pages: 781-784

10.1161/circep.114.002204 | PMID 25336364

Editor’s Perspective: In the Middle

Circulation: Arrhythmia and Electrophysiology | October 21, 2014 | Volume: 7 | Issue: 5 | Pages: 982-983

10.1161/circep.114.002202 | PMID 25336369

Femoral Approach to Lead Extraction

Journal of Cardiovascular Electrophysiology | October 13, 2014 | Volume: 26 | Issue: 3 | Pages: 357-361

10.1111/jce.12564 | PMID 25311643

Femoral ExtractionLaser and radiofrequency energy–assisted lead extraction has greatly facilitated this complex procedure. Although success rates are high, in some instances alternate methods of extraction are required. In this review, we discuss techniques for femoral extraction of implanted leads and retained fragments. The major tools available, including commonly used snares and delivery tools, are discussed. We briefly describe combined internal jugular and femoral venous extraction approaches, as well as complimentary utilization of more than one technique via the femoral vein. Animated and procedural sequences are included to help the reader visualize the key components of these techniques.
Successful Percutaneous Epicardial Access in Challenging Scenarios

Pacing and Clinical Electrophysiology | September 16, 2014 | Volume: 38 | Issue: 1 | Pages: 84-90

10.1111/pace.12503 | PMID 25223580

BackgroundThis case‐series highlights strategies used for successful epicardial access in challenging cases.Percutaneous epicardial access has become a valuable tool for mapping and ablating arrhythmias. However, this technique can be especially difficult in certain circumstances and is frequently avoided.MethodsAll cases of epicardial access for ablation from our institution were reviewed searching for exceptionally difficult cases in patients with complex pericardial and thoracic anatomy. The successful strategies are characterized in this report.ResultsAmong 144 patients who underwent an epicardial ablation procedure between January 2004 and June 2013, four required unconventional approaches for epicardial access for ventricular tachycardia ablation. Two patients (one with previous cardiac surgery and one with prior pericardial effusion) had substantial fibrous pericardial adhesions with no virtual pericardial space and required adhesiolysis. One patient, status postpartial colectomy, underwent computed tomography‐guided intercostal epicardial access due to the presence of bowel throughout the subdiaphragmatic space in the upper abdomen. The fourth patient had partial congenital absence of the pericardium and underwent epicardial access through the creation of a subxiphoid window. All epicardial accesses were successful and performed without major complication.ConclusionsWith precise procedural planning and cardiac imaging, percutaneous epicardial access is feasible even in patients with significant anatomical challenges.
ICE Imaging of the Left Atrial Appendage

Journal of Cardiovascular Electrophysiology | September 2, 2014 | Volume: 25 | Issue: 11 | Pages: 1272-1274

10.1111/jce.12536 | PMID 25181549

Electroporation

Circulation: Arrhythmia and Electrophysiology | August 19, 2014 | Volume: 7 | Issue: 4 | Pages: 573-575

10.1161/circep.114.001999 | PMID 25140018