Citations 335

Location

Circulation: Arrhythmia and Electrophysiology | April 21, 2015 | Volume: 8 | Issue: 2 | Pages: 502-504

10.1161/circep.115.002642 | PMID 25900993

Endomyocardial biopsy-integrating electrode at the bioptome tip

Therapeutic Advances in Cardiovascular Disease | March 2, 2015 | Volume: 9 | Issue: 3 | Pages: 66-69

10.1177/1753944715574660 | PMID 25731185

Background: The addition of electroanatomic mapping to a standard echo-guided endomyocardial biopsy could identify areas of abnormal pathology and increase the diagnostic yield of the procedure. Methods and results: In this demonstration of a novel technique, a 45-year-old woman with clinical suspicion for cardiac sarcoidosis underwent right ventricular bipolar electroanatomical mapping with identification of areas of signal fractionation and low voltage. A bioptome, configured to record an electrogram from the tip, was then visualized on the three-dimensional electroanatomic mapping (3DEAM) system, and directed to these areas. The biopsy was assisted by the use of a steerable introducer sheath, and by recording unipolar and extended bipolar signals from the bioptome tip. A prominent change in the signal was detected by the electrode at the bioptome tip when the jaws closed on the endomyocardial tissue. Patient tolerated the procedure without complications, and the biopsied samples were appropriate for pathological analysis. Conclusions: Using existing technology, the 3DEAM, which integrates unipolar and bipolar signal from the bioptome tip, is feasible, and can be safely added to a standard echocardiographically guided endomyocardial biopsy. Future studies should investigate whether such a technique could increase the safety and diagnostic yield of endomyocardial biopsies in patients with suspected cardiomyopathies.
Taking the Slower Pathway

Circulation: Arrhythmia and Electrophysiology | February 17, 2015 | Volume: 8 | Issue: 1 | Pages: 236-238

10.1161/circep.115.002641 | PMID 25691558

Troubleshooting Implantable Cardioverter-Defibrillator Sensing Problems II

Circulation: Arrhythmia and Electrophysiology | February 17, 2015 | Volume: 8 | Issue: 1 | Pages: 212-220

10.1161/circep.114.002514 | PMID 25691555

Atrioventricular Node Ablation in Langendorff-Perfused Porcine Hearts Using Carbon Ion Particle Therapy

Circulation: Arrhythmia and Electrophysiology | January 22, 2015 | Volume: 8 | Issue: 2 | Pages: 429-438

10.1161/circep.114.002436 | PMID 25609687

Background— Particle therapy, with heavy ions such as carbon-12 ( 12 C), delivered to arrhythmogenic locations of the heart could be a promising new means for catheter-free ablation. As a first investigation, we tested the feasibility of in vivo atrioventricular node ablation, in Langendorff-perfused porcine hearts, using a scanned 12C beam. Methods and Results— Intact hearts were explanted from 4 (30–40 kg) pigs and were perfused in a Langendorff organ bath. Computed tomgraphic scans (1 mm voxel and slice spacing) were acquired and 12 C ion beam treatment planning (optimal accelerator energies, beam positions, and particle numbers) for atrioventricular node ablation was conducted. Orthogonal x-rays with matching of 4 implanted clips were used for positioning. Ten Gray treatment plans were repeatedly administered, using pencil beam scanning. After delivery, positron emission tomography-computed tomgraphic scans for detection of β + ( 11 C) activity were obtained. A 12 C beam with a full width at half maximum of 10 mm was delivered to the atrioventricular node. Delivery of 130 Gy caused disturbance of atrioventricular conduction with transition into complete heart block after 160 Gy. Positron emission computed tomgraphy demonstrated dose delivery into the intended area. Application did not induce arrhythmias. Macroscopic inspection did not reveal damage to myocardium. Immunostaining revealed strong γH2AX signals in the target region, whereas no γH2AX signals were detected in the unirradiated control heart. Conclusions— This is the first report of the application of a 12 C beam for ablation of cardiac tissue to treat arrhythmias. Catheter-free ablation using 12C beams is feasible and merits exploration in intact animal studies as an energy source for arrhythmia elimination.
Electrophysiologic Characteristics of Ventricular Arrhythmias Arising From the Aortic Mitral Continuity – Potential Role of the Conduction System

Journal of Cardiovascular Electrophysiology | January 15, 2015 | Volume: 26 | Issue: 4 | Pages: No page available

10.1111/jce.12614 | PMID 25588295

Pericardial Effusion Following Drain Removal after Percutaneous Epicardial Access for an Electrophysiology Procedure

Pacing and Clinical Electrophysiology | January 13, 2015 | Volume: 38 | Issue: 3 | Pages: 383-390

10.1111/pace.12565 | PMID 25583074

ObjectivesTo determine the frequency and predictors of pericardial effusion following epicardial sheath removal.BackgroundPericardial effusion can occur following cardiac surgical or interventional procedures including percutaneous epicardial access (EpiAcc), which is increasingly used as part of electrophysiology ablation procedures.MethodsA retrospective analysis of the Mayo Clinic comprehensive electronic medical record was performed from all patients who underwent planned EpiAcc as part of an electrophysiology ablation procedure between January 1, 2004 and June 30, 2013.ResultsOf 144 patients (mean age 51.3 ± 15.5 years, 68% male) who underwent planned EpiAcc as part of an electrophysiology ablation (95.8% pericardial access success rate), seven (4.9%) developed a postoperative pericardial effusion requiring repeat EpiAcc. Inferior access was utilized in 74 (51.4%) patients. Patients with pericardial effusion tended to be younger (41.1 years vs 51.8 years, P = 0.08) and were more likely to have undergone inferior approach access (85.7% vs 49.6%, P = 0.06) than those who did not develop postoperative pericardial effusion. Seventy‐one percent of patients with postoperative pericardial effusion versus 32.1% of patients without postoperative pericardial effusion had a preprocedure ejection fraction ≥55% (P = 0.03). There were no procedural‐related deaths, and no difference in mortality between groups.ConclusionsPostoperative pericardial effusion requiring repeat access/drainage was relatively infrequent, occurring in 4.9% of patients shortly after epicardial procedures. While the majority occur early and therefore require close observation, some patients may present in a delayed manner.
Percutaneous Epicardial Access for Mapping and Ablation Is Feasible in Patients With Prior Cardiac Surgery, Including Coronary Bypass Surgery

Circulation: Arrhythmia and Electrophysiology | January 10, 2015 | Volume: 8 | Issue: 1 | Pages: 94-101

10.1161/circep.114.002349 | PMID 25575533

Background— Prior cardiac surgery, especially the presence of coronary artery bypass grafts, is thought to preclude percutaneous epicardial access (EpiAcc) and, therefore, mapping and ablation. We evaluated the feasibility and safety of EpiAcc in patients with a prior cardiac operation. Methods and Results— We retrospectively analyzed all patients who underwent EpiAcc for ablation for ventricular tachycardia or symptomatic premature ventricular complexes between 2004 and 2013 at Mayo Clinic, Rochester, MN. Of 162 patients who underwent EpiAcc, 18 had prior cardiac surgery (median age, 64 years, all men). This included 10 coronary artery bypass grafts, 2 epicardial implantable cardioverter defibrillator placement, 5 valve surgery, 2 septal myectomy, 1 aortic arch replacement, 1 myocardial bridge unroofing, and 1 myocardial perforation repair (3 patients had multiple procedures). Access was successful in 12 of 18; the inferior approach was used in 78%. Successful access was achieved in 6 of 10 patients with prior coronary artery bypass grafts. Adhesiolysis was required in 10 patients with the sheath, access wire, and pigtail or ablation catheter. Intraprocedural coronary angiography was performed in 8 patients. A total of 45 ventricular tachycardias/premature ventricular complexes were ablated. Thirteen patients underwent endocardial-only ablation, 2 had epicardial-only ablation, whereas 3 had endocardial–epicardial ablation. Ablation was deemed successful in 13 of 18 patients. Four patients had bleeding complications (pericardial effusion, pericardial hematoma, hemoperitoneum, and pericardial tamponade). In patients with coronary grafts, there was no evidence of acute graft disruption. Conclusions— Percutaneous EpiAcc is feasible in patients with previous cardiac surgery, including coronary artery bypass grafts. However, adhesiolysis is frequently required. Although the risk of coronary graft injury is low, life-threatening complications may occur.
Effects on Repolarization Using Dynamic QT Interval Monitoring in Long‐QT Patients Following Left Cardiac Sympathetic Denervation

Journal of Cardiovascular Electrophysiology | January 5, 2015 | Volume: 26 | Issue: 4 | Pages: 434-439

10.1111/jce.12609 | PMID 25559122

Dynamic QT Interval Monitoring Post‐LCSDBackgroundVideoscopic left cardiac sympathetic denervation (LCSD) is an adjunct therapy for reduction of arrhythmia‐induced events in patients with long‐QT syndrome (LQTS). LCSD reduces LQTS‐triggered breakthrough cardiac events. The temporal effects of QTc changes post‐LCSD have not been studied.MethodsWe utilized continuous QTc monitoring on 72 patients with LQTS. We evaluated acute and long‐term QTc changes in comparison to 12‐lead ECG‐derived QTc values prior to surgery, 24 hours postsurgery, and at follow up ≥3 months.ResultsSeventy‐two patients underwent LCSD at our institution (46% male, mean age at LCSD was 14 ± 10 years). The mean baseline, pre‐LCSD QTc was 505 ± 56 ms, which had decreased significantly at ≥3 months post‐LCSD to 491 ± 40 ms (P = 0.001). QTc monitoring revealed that the majority of the cohort (53/72; 74%) had a transient increase >30 ms in QTc from baseline, with an average maximum increase of 72 ± 30 ms. Resolution within 10 ms of baseline or less occurred in 57% (30/53) at 24 hours post‐LCSD.ConclusionsAlthough LQTS patients may have a paradoxically increased QTc post‐LCSD, the effects are transient in most patients. Importantly, no patients experienced any arrhythmias in the postoperative setting related to this transient rise in QTc.
Bypass Tracts Revisited

Circulation: Arrhythmia and Electrophysiology | December 16, 2014 | Volume: 7 | Issue: 6 | Pages: 1268-1270

10.1161/circep.114.002475 | PMID 25516584