Citations 335

Percutaneous Pericardial Resection

Circulation: Heart Failure | April 11, 2017 | Volume: 10 | Issue: 4 | Pages: No page available

10.1161/circheartfailure.116.003612 | PMID 28396500

Background— People with heart failure and preserved ejection fraction develop increases in left ventricular (LV) end-diastolic pressures during exercise that contribute to dyspnea. In normal open-chest animal preparations, the pericardium restrains LV filling when central blood volume increases. We hypothesized that resection of the pericardium using a minimally invasive epicardial approach would mitigate the increase in LV end-diastolic pressure that develops during volume loading in normal and diseased hearts with the chest intact. Methods and Results— Invasive hemodynamic assessment was performed at baseline and after saline load before and after pericardial resection in normal canines with open (n=3) and closed chest (n=5) and in a pig model with features of human heart failure and preserved ejection fraction with sternum intact (n=4). In closed-chest animals, pericardiotomy was performed using a novel subxiphoid procedure. In both experimental preparations of normal dogs, pericardiotomy blunted the increase in LV end-diastolic pressure with saline infusion, while enhancing the saline-mediated increase in LV end-diastolic volume. With chest intact in the pig model, percutaneous pericardial resection again blunted the increase in LV end-diastolic pressure secondary to volume expansion (+4±3 versus +13±5 mm Hg; P =0.014), while enhancing the saline-mediated increase in LV end-diastolic volume (+17±1 versus +10±2 mL; P =0.016). Conclusions— This proof of concept study demonstrates that pericardial resection through a minimally invasive percutaneous approach mitigates the elevation in LV filling pressures with volume loading in both normal animals and a pig model with diastolic dysfunction. Further study is warranted to determine whether this method is safe and produces similar acute and chronic hemodynamic benefits in people with heart failure and preserved ejection fraction.
Impact of atrial fibrillation on platelet gene expression

European Journal of Haematology | March 17, 2017 | Volume: 98 | Issue: 6 | Pages: 615-621

10.1111/ejh.12879 | PMID 28306170

AbstractAimsPlatelets retain cytoplasmic messenger RNA and are capable of protein biosynthesis. Several diseases are known to impact the platelet transcriptome but the effect of non‐valvular atrial fibrillation (NVAF) on platelet RNA transcript is essentially unknown. The aim of this study was to evaluate the impact of NVAF on platelet RNA transcript by measuring platelet genes expression in consecutive NVAF patients before and 3‐4 months after pulmonary vein isolation (PVI) and compared to normal sinus rhythm controls (NSR).Methods and ResultsRNA from isolated platelets were reverse transcribed, assayed against 15 genes using real‐time qPCR, and expressed as mean cycle threshold (ΔCt) using beta‐2‐microglobulin as endogenous control. Expression of all evaluated genes, except cathepsin A gene, was significantly lower (higher ΔCt) in 103 NVAF patients compared to 55 NSR controls. Insulin‐like growth factor binding protein acid labile subunit gene (IGFALS) had expression more than 16 fold‐lower (17.0±2.8 vs 12.5±3.8, P<.001), follow by genes encoding for prostacyclin receptor, and for von Willebrand factor which had fourfold lower expression compared to NSR controls. Gender, type of atrial fibrillation, heart failure, hypertension, prior stroke, diabetes mellitus, and atherosclerosis were associated with different gene expression. Following PVI, expression of four genes significantly increased, particularly IGFALS gene (increased 256‐fold) and ADAMT gene increased 16‐fold); expression of three genes significantly decreased, and expression of eight genes has not changed.ConclusionsPlatelets are capable to respond to the circulatory environment of NVAF by altering transcript and changing prothrombotic status. This shows platelet potential for molecular “reprogramming” possibly induced by flow disturbances of NVAF.
Incidence of Idiopathic Ventricular Arrhythmias

Circulation: Arrhythmia and Electrophysiology | February 9, 2017 | Volume: 10 | Issue: 2 | Pages: No page available

10.1161/circep.116.004662 | PMID 28183845

Background— Ventricular tachycardia and premature ventricular complexes (PVCs) most frequently occur in the context of structural heart disease. However, the burden of idiopathic ventricular arrhythmias (IVA) in the general population is unknown. Methods and Results— We identified incident cases of IVA between 2005 and 2013 from Olmsted County, Minnesota, using the Rochester Epidemiology Project database. For PVC cohorts, we included those with frequent (defined as ≥100 PVC/24 hours) symptomatic PVCs. We defined IVA-associated cardiomyopathy as a drop in ejection fraction of ≥10% from baseline. Between 2005 and 2013, we identified 614 individuals with incident IVA (229 [37.3%] were male; average age was 52.1±17.2 years). Of these, 177 (28.8%) had idiopathic ventricular tachycardia, 408 (66.5%) had symptomatic PVCs, and 29 (4.7%) had IVA-associated cardiomyopathy. The age- and sex-adjusted incidence rates in 2005 to 2007, 2008 to 2010, and 2011 to 2013 were 44.9 per 100 000 (95% confidence interval [CI], 38.0–51.8), 47.6 per 100 000 (95% CI, 40.8–54.5), and 62.0 per 100 000 (95% CI, 54.4–69.6), respectively. In idiopathic ventricular tachycardia, there was an increase in incidence rate with ages ( P <0.001) but not between sexes ( P =0.12). The age-adjusted incidence of symptomatic PVC was higher in females than in males (46.2 per 100 000 [95% CI, 40.9–51.6] versus 20.5 per 100 000 [95% CI, 16.8–24.3]; P <0.001). The small number of individuals with IVA-associated cardiomyopathy precluded any formal testing. Conclusions— The incidence of IVA is increasing. Furthermore, overall incidence increases with age. Although the rate of idiopathic ventricular tachycardia is similar across sexes, women have a higher incidence of symptomatic PVC.
Lead Extraction: The Importance of Preparation and Remaining Opportunities

Journal of Cardiovascular Electrophysiology | February 8, 2017 | Volume: 28 | Issue: 4 | Pages: 474-476

10.1111/jce.13173 | PMID 28176412

Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery

Pacing and Clinical Electrophysiology | February 7, 2017 | Volume: 40 | Issue: 5 | Pages: 476-481

10.1111/pace.13042 | PMID 28169434

BackgroundMagnetic resonance imaging (MRI) in patients with non‐MRI‐conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported.MethodsProspective data were collected between January 2008 and May 2015 in patients with non‐MRI‐conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events.ResultsMRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power‐on‐reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005.ConclusionPatients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing.
Burden of Arrhythmia in Pregnancy

Circulation | February 2, 2017 | Volume: 135 | Issue: 6 | Pages: 619-621

10.1161/circulationaha.116.026681 | PMID 28154000

Fascicular Ventricular Arrhythmias

Circulation: Arrhythmia and Electrophysiology | January 14, 2017 | Volume: 10 | Issue: 1 | Pages: No page available

10.1161/circep.116.002476 | PMID 28087563

High‐resolution electrical mapping of porcine gastric slow‐wave propagation from the mucosal surface

Neurogastroenterology & Motility | December 30, 2016 | Volume: 29 | Issue: 5 | Pages: No page available

10.1111/nmo.13010 | PMID 28035728

AbstractBackgroundGastric motility is coordinated by bioelectrical slow waves, and gastric dysrhythmias are reported in motility disorders. High‐resolution (HR) mapping has advanced the accurate assessment of gastric dysrhythmias, offering promise as a diagnostic technique. However, HR mapping has been restricted to invasive surgical serosal access. This study investigates the feasibility of HR mapping from the gastric mucosal surface.MethodsExperiments were conducted in vivo in 14 weaner pigs. Reference serosal recordings were performed with flexible‐printed‐circuit (FPC) arrays (128‐192 electrodes). Mucosal recordings were performed by two methods: (i) FPC array aligned directly opposite the serosal array, and (ii) cardiac mapping catheter modified for gastric mucosal recordings. Slow‐wave propagation and morphology characteristics were quantified and compared between simultaneous serosal and mucosal recordings.Key ResultsSlow‐wave activity was consistently recorded from the mucosal surface from both electrode arrays. Mucosally recorded slow‐wave propagation was consistent with reference serosal activation pattern, frequency (P≥.3), and velocity (P≥.4). However, mucosally recorded slow‐wave morphology exhibited reduced amplitude (65‐72% reduced, P<.001) and wider downstroke width (18‐31% wider, P≤.02), compared to serosal data. Dysrhythmias were successfully mapped and classified from the mucosal surface, accorded with serosal data, and were consistent with known dysrhythmic mechanisms in the porcine model.Conclusions & InferencesHigh‐resolution gastric electrical mapping was achieved from the mucosal surface, and demonstrated consistent propagation characteristics with serosal data. However, mucosal signal morphology was attenuated, demonstrating necessity for optimized electrode designs and analytical algorithms. This study demonstrates feasibility of endoscopic HR mapping, providing a foundation for advancement of minimally invasive spatiotemporal gastric mapping as a clinical and scientific tool.
Evaluation of a Unique Defibrillation Unit with Dual‐Vector Biphasic Waveform Capabilities: Towards a Miniaturized Defibrillator

Pacing and Clinical Electrophysiology | December 19, 2016 | Volume: 40 | Issue: 2 | Pages: 108-114

10.1111/pace.12979 | PMID 27990645

BackgroundAutomated external defibrillators can provide life‐saving therapies to treat ventricular fibrillation. We developed a prototype unit that can deliver a unique shock waveform produced by four independent capacitors that is delivered through two shock vectors, with the rationale of providing more robust shock pathways during emergent defibrillation. We describe the initial testing and feasibility of this unique defibrillation unit, features of which may enable downsizing of current defibrillator devices.MethodsWe tested our defibrillation unit in four large animal models (two canine and two swine) under general anesthesia. Experimental defibrillation thresholds (DFT) were obtained by delivery of a unique waveform shock pulse via a dual‐vector pathway with four defibrillation pads (placed across the chest). DFTs were measured and compared with those of a commercially available biphasic defibrillator (Zoll M series, Zoll Medical, Chelmsford, MA, USA) tested in two different vectors. Shocks were delivered after 10 seconds of stable ventricular fibrillation and the output characteristics and shock outcome recorded. Each defibrillation series used a step‐down to failure protocol to define the defibrillation threshold.ResultsA total of 96 shocks were delivered during ventricular fibrillation in four large animals. In comparison to the Zoll M series, which delivered a single‐vector, biphasic shock, the energy required for successful defibrillation using the unique dual‐vector biphasic waveform did not differ significantly (P = 0.65).ConclusionsOur early findings support the feasibility of a unique external defibrillation unit using a dual‐vector biphasic waveform approach. This warrants further study to leverage this unique concept and work toward a miniaturized, portable shock delivery system.
Expecting the Expected

Circulation: Arrhythmia and Electrophysiology | December 13, 2016 | Volume: 9 | Issue: 12 | Pages: No page available

10.1161/circep.116.004726 | PMID 27956435