Citations 335

Abstract 14833: National Trends in Complications and 30-day Re-hospitalization After Lead Removal/extraction: Analysis From a Cohort Of 42,878 Patients

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.14833

Introduction: As the US population ages and indications for cardiac device implantation expand, there is a concomitant increase in patients undergoing lead removal/extraction (LR/E).. We sought to examine trends in outcomes and complications associated with LR/E. Methods: We conducted a retrospective analysis using data from a large U.S. commercial insurance database (privately insured and Medicare Advantage patients) identifying all patients undergoing LR/E between 2004 and 2013 with at least one year continuous medical plan enrollment prior to LR/E (to identify baseline comorbidities). Using ICD9 codes and CPT codes, major complications (hemorrhage requiring transfusion, vascular injury, pericardial complications, respiratory complications, cerebrovascular complications, and requirement for cardiac surgery) associated with LR/E and 30-day readmission rates were evaluated. Results: Among 42,878 patients who underwent LR/E (median age of 62 ( 54, 72) years, 70% male); approximately 1 in 40 experienced a major adverse event (2.4%) during the study period. Respiratory complications were the most common complication and 311 patients required cardiac surgery. 30-day readmission occurred in 11.1% of the total population. The most common reasons for readmission were heart failure exacerbation (18.7%) and device related complications (13.2%). Conclusion: The observed complication rates after LE/R in clinical practice are similar to those seen in recent clinical trials and have been relatively stable over the past 10 years.
Abstract 12776: Long Term Mortality With Right Ventricular Apical Versus Septal Pacing

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12776

Introduction: Right ventricular apical (RVA) pacing appears to have detrimental effects on cardiac function and long term outcomes. Right ventricular non-apical (RVNA) pacing, especially in the septal position, has been postulated as an alternative that may lead to less morbidity and mortality. Prior studies have shown conflicting results and been limited by small numbers and short follow-up. We aimed to determine if right ventricular septal lead position was associated with a reduction in long-term mortality compared to RVA lead position. Methods: Patients who underwent dual-chamber pacemaker implantation from 2004 through 2013 were evaluated for right ventricular lead position based on chest radiographs. Lead positions were divided in to apical or non-apical. Non-apical lead positions were subdivided to isolate a septal lead position group. Mortality was compared between these groups. Results: During the study period, 3456 patients underwent dual-chamber pacemaker placement and had images appropriate for lead position evaluation. The group was 53.5% male with a mean age of 74 ± 13 years. RVNA lead position was found in 976 (28.2%) patients, including 243 (7.0%) with a septal position. There was no significant difference in age or prior heart failure diagnosis between groups. Kaplan-Meier survival analysis did not reveal a significant difference in mortality between patients with RVA versus RVNA lead position during 5 year follow-up (p = 0.82). However, septal lead position was associated with a significantly lower mortality compared with RVA position (p = 0.03) (figure). Conclusions: Right ventricular septal lead position is associated with a lower long-term mortality than RVA lead position. This has substantial implications regarding the preferred site for ventricular pacing lead placement.
Abstract 12112: Clinical Outcomes of Percutaneous Epicardial Ablation

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12112

Introduction: Percutaneous epicardial access (EAc) is increasingly performed as part of VT/PVC ablation, especially in those that have failed prior ablation. We aimed to delineate the outcomes of EAc. Methods: We retrospectively analyzed individuals undergoing EAc for arrhythmia ablation between June 2004 and July 2014. Acute procedural success was defined as elimination/non-inducibility of the clinical arrhythmia after ablation; clinical success was defined as absence of symptoms/arrhythmia. Results: Of 175 patients, 126 (72%) were male with a mean age of 52.8±15.7 years. Eighty-three (47.4%) patients had NICM, 25 (14.3%) had ICM and 34 (19.4%) had normal hearts. Baseline EF was 44±16%. Patients had failed an average of 1.7±1.2 antiarrhythmic drugs; 139 patients (79%) had failed prior endocardial (endo) ablation (average 1.3±1.1). Six (3.4%) had prior EAc and 18 (10.3%) prior cardiac surgery. The indication for ablation was VT or PVC in 113 (64.6%) and 60 (34.3%) patients, respectively. Successful access was obtained in 168 (98%) patients. Anterior access, inferior access, or both, was utilized in 89 (52.7%), 77 (45.6%) and 2 (1.2%) patients, respectively. There were an average of 2.7±2.2 VT/PVCs identified, and 1.6±1.1 ablated. Endo, epicardial (epi) or combined ablation was performed in 58 (33.1%), 14 (8%), and 100 (57.1%) patients, respectively; 3 did not undergo ablation. Procedural success was obtained in 158 of 173 (91.3%) patients for whom data was available. At 12 months, clinical success was maintained in 62% with no difference between endo, epi or combined ablation (figure). Cardiac tamponade requiring repeat EAc occurred in 12 (6.9%) patients. There were no procedural related deaths. Conclusion: Epicardial access is feasible in almost all patients with no prior cardiac surgery, and permits acute procedural success in 91.3% of patients, most of whom had failed previous ablation. Furthermore, complications are relatively infrequent in this complex cohort.
Abstract 2750: Multi-detector Computed Tomography Is An Accurate Screening Imaging Modality For Detection Of Thrombus In Patients Undergoing Catheter Ablation Of Atrial Fibrillation

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_610-b

Introduction Multi-detector computed tomography (MDCT) is commonly used to identify pulmonary vein and left atrial anatomy prior to catheter ablation for atrial fibrillation (CAAF). Additionally, transesophageal echocardiography (TEE) is utilized to exclude left atrial/left atrial appendage thrombus (ICT). Whether MDCT alone can be used to exclude thrombus obviating the need for TEE is unknown. Methods All Pts referred for CAAF at Mayo Clinic between March 2004 and October 2006 were included. Clinical data (including CHADS score), 64 slice MDCT (non-ECG gated), TEE and intra-cardiac echocardiograph (ICE) were all performed and recorded. Image data was reviewed independently and blinded. The left atrial appendage (LAA) was defined as fully opacified or underfilled. An underfilled LAA was further interrogated using a region of interest over the filling defect and mean attenuation in Hounsfield Units (HU) were recorded. Results In total 400 Pts (mean age 56 ± 10 yrs; 76% male; EF 56 ± 10 % ) were included. 362 had no ICT by TEE nor filling defect by MDCT. 38 patients had an underfilled LAA in whom ICT was confirmed by TEE in 7. Sensitivity and specificity of MDCT for ICT was 100% and 92% respectively with a NPV of 100%. In 19 Pts with underfilled LAA’s, a mean LAA emptying velocity was found to be significantly reduced at 26 cm/s (6 – 61 cm/s). Those with a thrombus had a mean attenuation value below 70 HU. CHADS2 score was higher (2.0 versus 1.0) in Pts with LAA filling defect versus those without LAA filling defect. All Pts with confirmed thrombus were taking Warfarin. ICT was not seen in any Pts aged <52 yrs with CHADS score ≤1. Conclusions Sensitivity and specificity of MDCT for detection of LAA thrombus is high. LAA filling defects on MDCT correlate with low emptying velocities by TEE and low attenuation value in HU. These data would suggest that in the absence of MDCT filling defect, no further imaging is required. TEE should be utilized prior to CAAF to investigate MDCT filling defects. Multidetector Computed Tomography for the Detection of LAA Thrombus
Abstract 2700: Reduced Ejection Fraction is Associated with Poor Outcomes in Adults with Left Ventricular Noncompaction Syndrome

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_599

Introduction Left ventricular non-compaction (LVNC) is a rare cardiomyopathy thought to result from intrauterine arrest of myocardial compaction which has been associated with and increased risk of sudden cardiac death (SCD). However, appropriate identification of at-risk individuals and risk-stratification is lacking, particularly in patients diagnosed during adulthood. We sought to identify high-risk patients wtih LVNC in order to guide therapy. Hypothesis That patients with decreased left ventricular ejection fraction (LVEF) would have worse outcomes than those with preserved left ventricular function. Methods We reviewed outcomes in all patients diagnosed with LVNC at Mayo Clinic between 2001 through 2006. Data were prospectively entered into a centralized database and retrospectively analyzed. Mortality was compared to age and sex matched population rates. Results A total of 80 patients were diagnosed with LVNC during this interval. After exclusion of pediatric patients (n = 21), 59 adult patients (62% male; age 46 ± 19 years, range 18–83) were analyzed. There were 4 deaths in this group (none due to stroke, mortality 18% at 2 years) during follow-up (mean 13.0 ± 13.5 months, range 0–52). Overall survival of patients with LVNC was worse than age and sex matched controls (Minnesota population p < 0.001). This was also noted in patients with LVEF > 35% (n = 35, p = 0.02). Overall LVEF was 41 ± 16% but was lower in patients who died compared to survivors (26 ± 10% vs. 42 ± 15%; Hazard ratio = 2.0 for a decrease in ejection fraction of 10%, p = 0.12). There were no deaths in patients with LVEF > 50% (n = 17). Conclusion Survival of adults with LVNC is worse than expected for age and sex. A decrease in ejection fraction is associated with increased risk of death in this population. These data suggest that patients diagnosed with LVNC and reduced LVEF may benefit from ICD implantation, whereas patients with a normal LVEF may be observed.
Abstract 2244: A Novel Micropace-Ablate Protocol Eliminates Coagulum Formation in Radiofrequency Ablation

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_489-a

Radiofrequency (RF) ablation for cardiac arrythmias is an established curative therapy. However, catheter-tip coagulum formation leading to thromboembolic stroke is a persistent problem despite heparinization. Recent studies demonstrated an up to 70% incidence of thrombus formation on the catheter tip during ablation and a 10 % incidence of thromboembolic events. Catheter tip thrombus can impede the delivery of RF energy to the tissue, resulting in reduced efficacy and longer procedure times. Here we report on a novel method to prevent coagulum formation on ablation catheters by delivering a negative charge to the catheter tip to repel negatively charged fibrinogen molecules during RF ablation. A novel circuit was built with a charge delivery unit using a 9 voltage battery to deliver a fixed offset direct current charge, placed in parallel to the RF delivery unit for negative charge placement during RF delivery. In in-vivo canine experiments (n=50) standard 6/4, 8/5 ablation catheters and catheters with abraded tips were advanced from right femoral veins into atria and ventricles under intra-cardiac echo (ICE) and biplane fluoroscopic guidance. The dogs received 1 of 2 therapies: no RF energy delivered with and without negative charge delivery, RF energy delivery with and without negative charge delivery. The presence of thrombus was identified with ICE. The catheter tips were examined also macroscopically with visual inspection and also with field emission scanning electron microscopy (FESEM). FESEM of the catheter tips showed surface coverage of fibrin clot of the catheter tip to be 90 % for non-charged catheters compared to 0 % (p< 0.01) in negatively-charged catheters. There was no significant difference in surface coverage of fibrin clot between negatively-charged catheters with the abraded tips (98.8%) and non-charged catheters with smooth tips (90.7 %, p=ns). Clot volume formed on the catheter tip decreased with increased amount of charge. Application of a negative charge did not affect the quality of the intracardiac electrograms or induce malignant ventricular arrhythmias. Negative charge delivery during RF ablation is feasible and safe and can eliminate coagulum formation, potentially reducing thromboembolic complications.
Abstract 1733: Complete Ablation of Typical Atrial Flutter in Patients with Corrected Congenital Heart Defects: “Non-Traditional” Access to the Surgically Excluded Cavotricuspid Isthmus

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_365-b

Background: Although multiple macroreentrant atrial flutters are seen in postoperative patients with congenital heart disease, cavotricuspid isthmus (CVTI) dependent flutter remains a fairly common arrhythmia in this group. When a Fontan or atrial switch (Mustard/Senning) type of procedure is performed, a portion of the CVTI is excluded from catheter access obtainable via a systemic venous route. We evaluated different techniques to access this excluded portion and completely ablate CVTI dependent flutter. Methods/Results: Between 1990 and 2007, 140 patients with surgically corrected congenital heart disease underwent an ablation procedure at our institution. Their records were reviewed to identify those with prior Fontan or atrial switch procedure who had documented CVTI dependent flutter requiring ablation. Data collected included methods of catheter access, circuits observed or induced, the location and number of ablation lines, immediate and long-term success, and complications. Results: Sixteen patients were identified (14, Fontan; 2, Mustard). In 12/16 (75%) patients bidirectional block of CVTI dependent flutter could not be achieved by right atrial (venous approach) ablation alone. In 7 of those, the excluded portion of the CVTI was targeted for ablation. This was accomplished by a retrograde transaortic approach via an interventricular communication then through the right atrioventricular valve (5 patients). Another retrograde transaortic approach was used with the catheter crossing the left atrioventricular valve then an atrial septal communication (one patient). A third approach involved an antegrade transconduit puncture (one patient). In all 7 patients, successful ablation of CVTI dependent flutter with bidirectional block was achieved. Post-procedure, one patient had temporary AV block requiring pacemaker placement. Follow-up was available on 4/7 patients (3 to 22 months, mean 10 months) with no documented recurrence of their CVTI dependent flutter. Conclusion: Even when surgical procedures exclude a portion of the CVTI, complete ablation for typical atrial flutter with resulting bidirectional block can be achieved via “non-traditional” approaches targeting the surgically excluded arrhythmogenic tissue.
Abstract 1544: Early Statin Therapy Reduces Risk Of ICD Shocks In Patients With An Implantable Cardioverter-defibrillator Undergoing Ablation For Ventricular Tachycardia

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_320-c

Background : Lipid lowering therapy reduces mortality in patients with both ischemic and nonischemic cardiomyopathies and recently has been shown to decrease ICD shocks. Radiofrequency ablation (RFA) of recurrent VT in patients with an ICD also reduces shocks following intervention. It is unclear if statin therapy after VT RFA will further impact ICD shock rates. Methods : All patients from 1993–2005 who underwent a RFA procedure for recurrent VT at the Mayo Clinic with an ICD were included. Patient records were extracted for medical and procedural details and all ICD interrogations were reviewed for VT recurrence and therapies. Results: 63 patients (age 62±15 years) were followed over 3.9±3.6 years. Comorbid diseases included: coronary artery disease 37(58%, 34 prior myocardial infarction), ARVD/C 6(10%), nonischemic dilated cardiomyopathy 7(11%), moderate-severe valve disease 14(22%), hypertension 34(54%), and hyperlipidemia 35(56%). Ejection fraction was <0.35 in 34(56%). VT was induced in all patients (LV 55 (LVOT 1), RV 8 (RVOT 3) with multiple inducible VTs in 21(33%). VT was noninducible after RFA in 39(62%) patients. Dismissal medications included: statins 19(30%), beta blockers 40(66%), ACE/ARB 37(61%), diuretics 34(55%), and digoxin 23(37%). 5-year overall survival was 63%(95% CI 55–71). Age, diabetes, and renal insufficiency were associated with increased post ablation mortality, with no medication improving survival. 5-year survival free of ICD shocks was 31%(95% CI 24–38). Only statin therapy at discharge was associated with a decreased risk of ICD shocks [5(26%) versus 26(59%), p=0.020]. 7 additional patients received statins during follow-up, but not at discharge, of these 5(71%) had shocks. Conclusion : Statin use at discharge in patients with an ICD undergoing RFA for refractory VT significantly reduced recurrent ventricular arrhythmias and ICD shocks. Although the mechanism underlying the effects of statins on arrhythmic recurrence early after RFA requires further study, these data support aggressive therapy of the underlying substrate responsible for the VT.
Abstract 637: Utilization of Retrograde Right Bundle Branch Block to Differentiate Atrio Ventricular Nodal from Accessory Pathway Conduction

Circulation | July 3, 2021 | Volume: 118 | Issue: suppl_18 | Pages: No page available

10.1161/circ.118.suppl_18.s_590-b

Determining whether retrograde ventriculoatrial (VA) conduction is through the AV node (AVN) or an accessory pathway (AP) is critical for successful ablation of supraventricular tachycardia (SVT). With introduction of ventricular extrastimuli (VEST), retrograde right bundle branch block (retro RBBB) may occur and result in abrupt VH interval prolongation. We hypothesized when retrograde conduction is via an AP, VA interval change is less than VH interval change, whereas with retrograde AVN conduction, VA interval change is equal to or greater than VH interval change. We retrospectively reviewed the electrophysiology (EP) studies of patients undergoing ablation for AVNRT (n=55) or AVRT (n=50). The intracardiac electrograms were reviewed for induction of retro RBBB and change in VH and VA intervals during VEST. Parahisian pacing, decremental pacing, arrhythmia diagnosis and ablation outcomes were reviewed. All results were found to be reproducible between two independent observers with inter and intra observer reliability scores of 1.00 for identification of retro RBBB and greater than 0.85 for measurement of VH and VA intervals. Of 105 patients, 84 (80%) had evidence of induced retro RBBB during VEST. The average VH interval increase with induction of retro RBBB was 53.7 ms for patients with retrograde AP conduction and 54.4 ms for patients with AVN conduction (p=ns). The average VA interval increase with induction of retro RBBB was 13.6 ms with AP conduction and 70.1 ms with AVN conduction (P < 0.001). All patients with a greater VH than VA interval change had a final diagnosis of AVRT and those with a VH change less than VA change had AVNRT, yielding sensitivity and specificity of 100%. Using a cutoff of 50 ms for change in VA interval with onset of retro RBBB to diagnose AVNRT accurately identified AVNRT in 100% and AVRT in 95%. Induction of retro RBBB during VEST is common during EP studies for SVT. The relative change in the VH and VA intervals during retro RBBB accurately differentiates retrograde AVN from retrograde AP conduction with strong predictive accuracy. The use of retro RBBB based intervals is a useful technique facilitating the diagnosis of SVT in the EP laboratory, even in the absence of inducible tachycardia.
Abstract 17289: Incidence of Cardiomyopathy and Mortality in Patients With Cobalt and Chromium Metal Hip Arthroplasty

Circulation | July 2, 2021 | Volume: 138 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.138.suppl_1.17289

Introduction: One million patients around the world have had total hip arthorplasty with 35% of them having metal-on-metal implants. Although there have been some case reports of cobalt cardiotoxicity from arthroprosthetic cobaltism resulting in dilated cardiomyopathy, incidence of cardiomyopathy and mortality in these patients is unknown. Objective: We therefore sought to determine the incidence of new onset cardiomyopathy (EF <40%) and associated mortality, in patients with metal hip arthroplasty. Methods: We retrospectively examined the records of the patients form our institutional total hip arthroplasty registry (Metal on Metal: MoM, Metal on Polyethylene: MoP, Ceramic on Ceramic: CoC and Ceramic on Polyethylne: CoP). Among 122 patients with baseline and follow up echocardiograms, cobalt and chromium levels were available in 12 patients, none of which developed incident cardiomyopathy. Results: The mean age of the population with metal group (MoM and MoP) was 53 years, predominantly males. During the follow up period of 10 years, the cumulative incidence (KM curve probabilities) of low EF <=40% in our study population was 14% in metal group as compared to 5% in non-metal group (CoC and CoP), (p value 0.51). At 15 years of follow up, among 122 patients, there were16 deaths in the metal group (81) and only 2 deaths in the non-metal group (41) (p value 0.15). Conclusions: In conclusion, although the incidence of cardiomyopathy as well as mortality is low in patients with metal hip arthroplasty and not significantly, further studies maybe needed to assess its effect on diastolic dysfunction.