Citations 48

Tenosynovitis of the Wrist and Thumb and Carpal Tunnel Syndrome Caused by Histoplasma Capsulatum : Case Report and Review of the Literature

HAND | February 17, 2014 | Volume: 10 | Issue: 1 | Pages: 54-59

10.1007/s11552-014-9611-4 | PMID 25762883

A patient presenting with acute carpal tunnel syndrome and swelling and pain in the wrist and thumb is presented. An open carpal tunnel release and tenosynovectomy were performed with biopsy specimen revealing infection with Histoplasma capsulatum. The case is discussed in context of the prior scant literature of tenosynovitis of the wrist and hand caused by histoplasmosis.
Reconstruction of Swan Neck Deformities after Proximal Interphalangeal Joint Arthroplasty

HAND | December 9, 2013 | Volume: 9 | Issue: 1 | Pages: 93-98

10.1007/s11552-013-9571-0 | PMID 24570644

Background The authors report the use of a single slip of the flexor digitorum superficialis (FDS) as a hemitenodesis through the A2 pulley in treating swan neck deformities after previous unconstrained proximal interphalangeal joint (PIP) arthroplasty. Methods A retrospective chart review was undertaken to identify non-constrained PIP joint arthroplasties that underwent a subsequent soft tissue hemitenodesis for swan neck deformities. The range of motion (ROM), implant design, preoperative diagnosis, and surgical approach were collected. The Michigan Hand Outcomes Questionnaire and patient satisfaction questionnaire were collected. Results There were 12 patients with 14 procedures reviewed. There were seven surface replacement arthroplasties (SRA) (cobalt chrome on polyethylene) and eight pyrocarbon prostheses. The primary diagnosis for the initial joint arthroplasty was osteoarthritis (8), post-traumatic (2), and rheumatoid arthritis (5). The primary dorsal approach was a longitudinal split in eleven cases, Chamay in two, and unknown in one case. Nine of the 14 revision procedures had a concomitant dorsal approach to the joint. The average final position intra-operatively was 24.2° of flexion (range 15°–40°). Final ROM was 39° with average follow-up of 30 months. The average postoperative radiographic position was 20.3° flexion with an average of 24.8° hyperextension preoperatively. There was one failure secondary to implant loosening requiring fusion. Discussion For patients with a swan neck deformity after PIP arthroplasty, a FDS hemitenodesis provides a treatment option with a low revision rate, retained motion, and maintenance of the original implant with no shortening of the digit.
Total Wrist Replacement: A Retrospective Comparative Study

Journal of Wrist Surgery | December 20, 2012 | Volume: 01 | Issue: 02 | Pages: 165-172

10.1055/s-0032-1326728 | PMID 24179722

Long-Term Outcomes of Proximal Row Carpectomy: A Minimum of 15-Year Follow-up

HAND | November 3, 2011 | Volume: 7 | Issue: 1 | Pages: 72-78

10.1007/s11552-011-9368-y | PMID 23449142

Introduction Proximal row carpectomy (PRC) is a popular procedure for the treatment of wrist arthritis; however, the long-term clinical outcomes of this procedure are not well-characterized. The purpose of this study was to evaluate long-term results with PRC and to identify factors that may improve clinical outcomes. Methods A retrospective study was performed on all patients who underwent proximal row carpectomy between January 1967 and January 1992. Medical records and available radiographs were reviewed. The Disabilities of the Arm, Shoulder and Hand, and Patient Rated Wrist Exam, as well as hand motion diagrams were sent to all surviving patients. The contralateral extremity was used as a control. Data was analyzed using multivariant analysis and a Student's t test. Results Eighty-one patients underwent PRC. Average age at the time of surgery was 41 years. Average follow-up was 19.8 years. Sixty-one patients responded to the questionnaires. On final follow-up, wrist motion and grip strength were not significantly different from preoperative values. Radiographic follow-up beyond 2 years revealed joint narrowing and arthritic changes within the radiocapitate joint. Forty-six patients (74%) were not satisfied with the results of their surgery due to persistent pain or inability to return to previous occupational activities. Fifty-two patients required daily pain medication for wrist pain. Twelve patients had undergone a wrist arthrodesis. Conclusions Post-operative motion and grip strength values following PRC appear to remain stable over time. Surgical failure rates with conversion to wrist fusion occurred early within the post-operative follow-up. Many patients continued to complain of pain requiring daily medication and were unable to return to manual labor type jobs. The results of this study suggest that long-term patient satisfaction following PRC can be poor and the surgeon may wish to consider alternative treatment options for younger patients and those with high-demand jobs.
Wrist arthrodesis as a salvage procedure for failed implant arthroplasty

Journal of Hand Surgery (European Volume) | July 11, 2010 | Volume: 36 | Issue: 1 | Pages: 29-33

10.1177/1753193410376283 | PMID 20621939

Salvage of failed total wrist arthroplasty by arthrodesis may be difficult because of bone loss and poor quality of bone and soft tissues. We examined the outcomes of wrist arthrodesis for failed total wrist arthroplasty in a retrospective study of 21 wrists in 17 patients. Clinical data, radiographs, patient-reported outcomes and DASH questionnaires were used. Thirteen women and four men had undergone total wrist arthroplasty at an average age of 55 years. The mode of failure was aseptic loosening in 13 wrists. The average time from the index arthroplasty to wrist arthrodesis was 7.6 years. Autograft and/or allograft bone graft was used in all of the wrists. Arthrodesis was achieved in 11 wrists and ten had a nonunion. Six arthrodeses underwent eight revisions for nonunion, with two achieving union. The mean DASH score was 29 in wrists that fused and 36 in those that did not fuse. Pain scores averaged 2.1 in the wrists that fused and 3.3 in the nonunion group. Most patients had clinical improvement.
Metacarpal Neck Fractures: Results of Treatment with Traction Reduction and Cast Immobilization

HAND | November 21, 2008 | Volume: 4 | Issue: 2 | Pages: 161-164

10.1007/s11552-008-9150-y | PMID 19030938

Although fractures of the fifth metacarpal neck (boxer's fractures) are common, their treatment can be problematic. A description of a technique utilizing traction reduction is presented in this paper. The records and radiographs of 59 patients who underwent reduction using longitudinal traction and subsequent immobilization in a specially molded cast were retrospectively reviewed. On average, 80% of initial fracture angulation in the sagittal plane was corrected, and only 1° of this correction was lost at the discontinuation of casting (3–4 weeks). We have found this technique to be highly effective in the treatment of boxer's fractures. Advantages of this treatment include its efficacy, ease, and improved patient tolerance over other casting techniques.
An Unusual Presentation of Acute Calcific Tendinitis in the Hand

HAND | July 22, 2008 | Volume: 4 | Issue: 1 | Pages: 81-83

10.1007/s11552-008-9121-3 | PMID 18780008

Acute calcific tendinitis (ACT) is a relatively uncommon disorder of the hand and wrist. ACT is a well-known condition of the shoulder, but it often goes unrecognized when occurring in the hand or wrist. The overall lack of familiarity along with the non-specific symptoms associated with ACT frequently leads to misdiagnosis or delay in diagnosis. We report a case of acute calcific tendinitis occurring in the carpal tunnel which is a rare presentation.
Comparison of Locked Volar Plating Versus Pinning and External Fixation in the Treatment of Unstable Intraarticular Distal Radius Fractures

HAND | October 16, 2007 | Volume: 3 | Issue: 2 | Pages: 111-117

10.1007/s11552-007-9080-0 | PMID 18780086

Introduction We retrospectively compared the outcomes of open reduction and internal fixation (ORIF) with volar locking plate versus standard external fixation and percutaneous pinning in treating similar unstable distal radius fractures with a minimum 2-year follow-up. Methods The ORIF group included 41 patients with an average follow-up of 29 months. The external fixation group comprised 14 patients with an average follow-up of 33 months. Average age at presentation was 45 years in the external fixation group and 48 years in the ORIF group. The male/female ratios were 16:25 among the ORIF group and 6:8 in the external fixation group. The two groups were compared for clinical and functional outcomes measured by the disabilities of the arm, shoulder, and hand (DASH) score. Pain scores were similar. Radiographic measurements were also evaluated between groups. Results Final ranges of motion and grip strengths were similar between the two groups. The mean DASH score of the locked volar plate group was 9 compared to 23 for the external fixation group. Radiographically, volar tilt and radial length were significantly better in the patients treated with ORIF. The ORIF group required less therapy visits. No complications occurred in the locked volar plate group whereas two patients had pin tract infections and one had prolonged finger stiffness in the external fixation group. Conclusion Locked volar plating compares favorably to external fixation and pinning for amenable fracture patterns. Whereas grip and range-of-motion data were similar, DASH scores, frequency of rehabilitation, and some radiographic parameters were superior in patients treated with ORIF.