Back to Authors

Tjoumakaris, Stavropoula

https://orcid.org/0000-0002-1054-9414

A5030396271 | I149251103

Mayo Clinic

Thomas Jefferson University

Citations 31

Outcomes of arteriovenous malformation patients with multiple versus single feeders: A multicenter retrospective study with propensity-score matching

European Stroke Journal | February 15, 2025 | Volume: 10 | Issue: 3 | Pages: 946-960

10.1177/23969873251319924 | PMID 39953956

Abstract Introduction The impact of multiple feeding arteries on clinical outcomes of cerebral arteriovenous malformations (AVMs) is not well understood. This study aims to compare outcomes between AVMs with multiple versus single feeding arteries. Patients and Methods Data from the Multicenter International Study for Treatment of Brain AVMs (MISTA) consortium were analyzed. Propensity score matching (PSM) was used to balance cohorts. Subgroup analysis was conducted for ruptured and unruptured AVMs and different treatment options, and multivariable logistic regression was applied to assess the impact of feeding artery origin. Results Among 953 patients, 661(69.4%) had multiple feeding arteries, and 292 (30.6%) had a single feeding artery. After PSM, which included 422 matched patients (211 in each group), the differences in obliteration rates (68.7% vs 74.8%, OR 0.73, 95% CI: 0.48–1.12, p = 0.16) and symptomatic complications (15.6% vs 11.8%, OR 1.37, 95% CI: 0.78–2.41, p = 0.25) were not significant. Subgroup analysis comparing ruptured and unruptured AVMs and different treatment options showed no significant differences across all subgroups. Multivariable analysis identified PICA feeders as significantly associated with increased odds of all complications (OR 7.33, 95% CI: 2.14–25.1, p = 0.002). Discussion and Conclusion AVMs with a single feeding artery were more likely to present with rupture, but no significant differences in obliteration rates or complications were observed between the groups after PSM. These findings suggest that while the number of feeding arteries may influence the initial presentation, it does not appear to impact overall treatment success or patient prognosis. Further prospective studies are needed to confirm these findings.
Comparative outcomes of arteriovenous malformations treatment in eloquent versus non-eloquent brain: A multicenter study with propensity-score weighting

International Journal of Stroke | February 14, 2025 | Volume: 20 | Issue: 7 | Pages: 852-863

10.1177/17474930251323503 | PMID 39948730

Background: Arteriovenous malformations (AVMs) are complex vascular anomalies with a high risk of hemorrhage and neurological deficits, especially when located in eloquent brain regions. The eloquence of an AVM location is a critical factor in the treatment planning, influencing both the risk of complications and long-term functional outcomes. This study aims to compare outcomes between eloquent and non-eloquent AVMs. Methods: This multicenter, retrospective study utilized data from the Multicenter International Study for Treatment of Brain AVMs (MISTA) consortium. Patients with eloquent and non-eloquent AVMs were compared on baseline characteristics, angiographic outcomes, and functional outcomes using the modified Rankin Scale (mRS). Propensity score weighting (IPTW) was applied to adjust for confounding variables. Results: The study included 1013 patients, with 498 (49.2%) AVMs located in eloquent regions and 515 (50.8%) in non-eloquent regions. In unadjusted analysis, eloquent AVMs had lower complete obliteration rates (67.6% vs 79.5%, OR: 0.53, 95% CI: 0.39–0.72, p < 0.001) and higher complication rates (24.5% vs 19.0%, OR: 1.38, 95% CI: 1.02–1.86, p = 0.03) compared to non-eloquent AVMs. After IPTW adjustment, eloquent AVMs continued to show significantly higher odds of overall complications (OR: 1.68, 95% CI: 1.12–2.52, p = 0.01) and symptomatic complications (OR: 1.77, 95% CI: 1.12–2.80, p = 0.01). Secondary analysis within the eloquent group indicated that embolization was linked to an elevated risk of complications. Surgery and radiosurgery showed comparable functional outcomes at last follow-up and complications rates with higher complete obliteration rates in surgery. Conclusion: AVMs in eloquent brain areas present higher risks of complications and lower obliteration rates, emphasizing the need for cautious, individualized treatment planning. Within the eloquent group, embolization increased the risk of complications, while surgery and radiosurgery showed comparable functional outcomes at last follow-up and complication rates with higher complete obliteration rates in surgery. These findings highlight the importance of location in AVM management and support further research focusing on comparing treatment strategies for AVMs in eloquent brain areas.
Efficacy and safety of preoperative embolization in surgical treatment of brain arteriovenous malformations: a multicentre study with propensity score matching

Journal of Neurology, Neurosurgery & Psychiatry | February 6, 2025 | Volume: 96 | Issue: 8 | Pages: 766-774

10.1136/jnnp-2024-334974 | PMID 39915091

Background Brain arteriovenous malformations (AVMs) are abnormal connections between feeding arteries and draining veins, associated with significant risks of haemorrhage, seizures and other neurological deficits. Preoperative embolization is commonly used as an adjunct to microsurgical resection, with the aim of reducing intraoperative complications and improving outcomes. However, the efficacy and safety of this approach remain controversial. Methods This study is a subanalysis of the Multicenter International Study for Treatment of Brain AVMs consortium. We retrospectively analysed 486 patients with brain AVMs treated with microsurgical resection between January 2010 and December 2023. Patients were divided into two groups: those who underwent microsurgery alone (n=245) and those who received preoperative embolization, followed by microsurgery (n=241). Propensity score matching was employed, resulting in 288 matched patients (144 in each group). The primary outcomes were rates of complete AVM obliteration and functional outcomes (measured by the modified Rankin Scale (mRS)). Secondary outcomes included complication rates, mortality, hospital length of stay and postsurgical rupture. Results After matching, the complete obliteration rate was 97% with no significant difference between the microsurgery-only group and the preoperative embolization group (p=0.12). The proportion of patients with an mRS score of 0–2 at the last follow-up was similar in both groups (83% vs 84%; p=0.67). The median hospital stay was significantly longer for the embolisation group (9 days vs 7 days; p=0.017). Complication rates (24% vs 22%; p=0.57) and mortality rates (4.9% vs 2.1%; p=0.20) were comparable between the two groups. No significant differences were observed in postsurgical rupture, recurrence or retreatment rates. Conclusions In this large multicentre study, preoperative embolization did not significantly improve AVM obliteration rates, functional outcomes or reduce complications compared with microsurgery alone.
Impact of smoking on recurrence rates among wide-neck intracranial aneurysms treated with Woven EndoBridge: a multicenter retrospective study

Journal of Neurosurgery | January 31, 2025 | Volume: 142 | Issue: 6 | Pages: 1732-1740

10.3171/2024.10.jns241058 | PMID 39889291

OBJECTIVE Tobacco smoking is among the factors known to significantly augment the risk of untreated intracranial aneurysm (IA) growth and rupture. Smoking appears to have a variable effect on different endovascular treatment modalities. The impact of smoking on the safety, efficacy, and outcomes of Woven EndoBridge (WEB) device use for wide-neck IAs has not been evaluated. This study aimed to investigate the outcomes of WEB devices by smoking status. METHODS A retrospective multicenter analysis was conducted on the data of patients from 36 sites worldwide treated with the WEB device for intracranial saccular aneurysms. Patients were stratified based on smoking status (current, former, and never smokers). The Student t-test and chi-square test were performed for continuous and categorical variables, respectively. Multivariable logistic regression was used to adjust for confounders. RESULTS Of 1376 patients with available smoking status, 504 were current smokers, 358 were former smokers, and 514 were never smokers. Upon adjusting for significant confounders, no association was found between smoking and recurrence outcomes (OR 1.39, 95% CI 0.69–2.80; p = 0.36), thromboembolic and hemorrhagic complications, and mortality among IAs treated with the WEB device. There was no statistically significant difference in outcomes between former and never smokers (OR 1.23, 95% CI 0.70–2.18; p = 0.46). The location of aneurysms differed between smoking groups, with former smokers having more anterior circulation aneurysms compared with current and never smokers (99.0% vs 96.9% vs 95.3%; p = 0.01). In terms of clinical symptoms, headache and dizziness were more common in the never smokers compared with current and former smokers (13.9% vs 8.9% vs 7.7%, p = 0.01). CONCLUSIONS This large-scale study suggests no significant correlation between smoking and the recurrence of IAs treated with the WEB device. Biological studies are warranted to better understand the biological impact of smoking on the growth and rupture of treated IAs.
Abstract 273: Evaluating Clinical Outcomes and Cost‐Effectiveness of Robotic Carotid Artery Stenting: A Multi‐Center, Propensity Score Matched Study

Stroke: Vascular and Interventional Neurology | January 15, 2025 | Volume: 4 | Issue: S1 | Pages: No page available

10.1161/svin.04.suppl_1.273

Objective Preclinical studies suggest that robotic carotid artery stenting (CAS) could be superior to manual CAS. However, very limited comparative data exists comparing robotic and manual CAS patients. In addition, no data exists comparing the costs of manual and robotic CAS. Methods All robotic CAS cases at 2 academic neurosurgery centers were retrospectively reviewed and 1:1 propensity matched with manual CAS cases. Personnel costs, supply costs, and total procedure costs were collected in collaboration with hospital administration using time‐driven activity‐based cost‐analysis (TDABC). Results 24 robotic CAS cases were performed between 2019 and 2023. Co‐morbidities and baseline procedural characteristics were well‐matched between robotic and manual cases. Unplanned manual conversion was observed in only one robotic case (4.2%). Robotic CAS complications and outcomes were comparable to manual. Robotic CAS was associated with a significantly increased fluoroscopy time (29.0 vs. 19.2 min.; p<0.001). Robotic procedure time (88.9±18.2 min.) was significantly (p=0.003) higher than manual (68.72±22.4 min.). Health professional costs ($1,589.71±176.92, $1,375.99±233.39, p<0.005), supply cost ($3,918.25±421.20, $2,152.74±1,030.26, p<0.001) and total procedure costs ($5,306.11±608.95, $3,437.56±1,165.67, p<0.001) were greater for robotic CAS. Conclusions With a low rate of technical failure and post‐operative complications, we show robotic carotid artery stenting is safe and feasible in the first multi‐center and largest sample to date. In addition, robotic CAS achieves comparable clinical outcomes. Robotic CAS was associated with increased fluoroscopy time, but fluoroscopy time decreased as operators gained familiarity with the CorPath GRX. Robotic CAS was associated with a greater procedural cost, which was driven by greater personnel and supply costs. Our findings highlight the need for further studies to optimize robotic CAS and reduce its associated costs.
Robotic carotid artery stenting: a multicenter, propensity score–matched analysis of clinical outcomes and cost-effectiveness

Neurosurgical Focus | December 1, 2024 | Volume: 57 | Issue: 6 | Pages: E10

10.3171/2024.9.focus24479 | PMID 39616641

OBJECTIVE Preclinical studies suggest that robotic carotid artery stenting (CAS) could be superior to manual CAS. However, very limited comparative data exist for patients who have undergone robotic versus manual CAS. In addition, no data exist comparing the costs of manual and robotic CAS. METHODS All robotic CAS cases at two academic neurosurgery centers were retrospectively reviewed and 1:1 propensity matched with manual CAS cases. Personnel costs, supply costs, and total procedure costs were collected in collaboration with hospital administration by using time-driven activity-based cost analysis. RESULTS A total of 24 robotic CAS operations were performed between 2019 and 2023. Comorbidities and baseline procedural characteristics were well matched between robotic and manual cases. Unplanned manual conversion was observed in only 1 robotic case (4.2%). Robotic CAS complications and outcomes were comparable to manual. Robotic CAS was associated with a significantly increased fluoroscopy time (29.0 vs 19.2 minutes; p < 0.001). Robotic procedure time (88.9 ± 18.2 minutes) was significantly (p = 0.003) longer than manual time (68.72 ± 22.4 minutes). Health personnel costs ($1589.71 ± $176.92 vs $1375.99 ± $233.39, p = 0.005); supply costs ($3918.25 ± $421.20 vs $2152.74 ± $1030.26, p < 0.001); and total procedure costs ($5306.11 ± $608.95 vs $3437.56 ± $1165.67, p < 0.001) were greater for robotic CAS. CONCLUSIONS In the first multicenter study and largest sample to date, the authors show that robotic CAS, with a low rate of procedural failure and postoperative complications, is safe and feasible. In addition, robotic CAS achieves comparable clinical outcomes to manual CAS. Robotic CAS was associated with increased fluoroscopy time, but fluoroscopy time decreased as operators gained familiarity with the CorPath GRX system. Robotic CAS was associated with a greater procedural cost, which was driven by greater personnel and supply costs. Robotic CAS failed to show superiority to manual CAS. These findings set a foundation for randomized controlled trials of robotic CAS, and also highlight the need for further studies to optimize robotic CAS and reduce its associated costs.
Defining ideal middle cerebral artery bifurcation aneurysm size for Woven EndoBridge embolization

Journal of Neurosurgery | October 12, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-11

10.3171/2024.5.jns232204 | PMID 39393093

OBJECTIVE The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors’ objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices.
Comparing stand-alone endovascular embolization versus stereotactic radiosurgery in the treatment of arteriovenous malformations with Spetzler-Martin grades I–III: a propensity score matched study

Journal of NeuroInterventional Surgery | October 4, 2024 | Volume: 17 | Issue: 12 | Pages: 1382-1390

10.1136/jnis-2024-022326 | PMID 39366733

Background Arteriovenous malformations (AVMs) are uncommon cerebral lesions that can cause significant neurological complications. Surgical resection is the gold standard for treatment, but endovascular embolization and stereotactic radiosurgery (SRS) are viable alternatives. Objective To compare the outcomes of endovascular embolization versus SRS in the treatment of AVMs with Spetzler-Martin grades I–III. Methods This study combined retrospective data from 10 academic institutions in North America and Europe. Patients aged 1 to 90 years who underwent endovascular embolization or SRS for AVMs with Spetzler-Martin grades I–III between January 2010 and December 2023 were included. Results The study included 244 patients, including 84 who had endovascular embolization and 160 who had SRS. Before propensity score matching (PSM), complete obliteration at the last follow-up was achieved in 74.5% of the SRS group compared with 57.8% of the embolization group (OR=0.47; 95% CI 0.26 to 0.48; P=0.01). After propensity score matching, SRS still achieved significantly higher occlusion rates at last follow-up (78.9% vs 55.3%; OR=0.32; 95% CI 0.12 to 0.90; P=0.03). Hemorrhagic complications were higher in the embolization group than in the SRS group, although this difference did not reach statistical significance after PSM (13.2% vs 2.6%; OR=5.6; 95% CI 0.62 to 50.47; P=0.12). Similarly, re-treatment rate was higher in the embolization group (10.5% vs 5.3%; OR=2.11; 95% CI 0.36 to 12.31; P=0.40) compared with the SRS group. Conclusion Our findings indicate that SRS has a significantly higher obliteration rate at last follow-up compared with endovascular embolization. Also, SRS has a higher tendency for fewer hemorrhagic complications and lower re-treatment rate. Further prospective studies are needed.
Creation of a predictive calculator to determine adequacy of occlusion of the woven endobridge (WEB) device in intracranial aneurysms—A retrospective analysis of the WorldWide WEB Consortium database

Interventional Neuroradiology | August 10, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199241267320 | PMID 39127463

Background Endovascular treatment with the woven endobridge (WEB) device has been widely utilized for managing intracranial aneurysms. However, predicting the probability of achieving adequate occlusion (Raymond–Roy classification 1 or 2) remains challenging. Objective Our study sought to develop and validate a predictive calculator for adequate occlusion using the WEB device via data from a large multi-institutional retrospective cohort. Methods We used data from the WorldWide WEB Consortium, encompassing 356 patients from 30 centers across North America, South America, and Europe. Bivariate and multivariate regression analyses were performed on a variety of demographic and clinical factors, from which predictive factors were selected. Calibration and validation were conducted, with variance inflation factor (VIF) parameters checked for collinearity. Results A total of 356 patients were included: 124 (34.8%) were male, 108 (30.3%) were elderly (≥65 years), and 118 (33.1%) were current smokers. Mean maximum aneurysm diameter was 7.09 mm (SD 2.71), with 112 (31.5%) having a daughter sac. In the multivariate regression, increasing aneurysm neck size (OR 0.706 [95% CI: 0.535–0.929], p = 0.13) and partial aneurysm thrombosis (OR 0.135 [95% CI: 0.024–0.681], p = 0.016) were found to be the only statistically significant variables associated with poorer likelihood of achieving occlusion. The predictive calculator shows a c-statistic of 0.744. Hosmer–Lemeshow goodness-of-fit test indicated a satisfactory model fit with a p-value of 0.431. The calculator is available at: https://neurodx.shinyapps.io/WEBDEVICE/ . Conclusion The predictive calculator offers a substantial contribution to the clinical toolkit for estimating the likelihood of adequate intracranial aneurysm occlusion by WEB device embolization.
Association of preprocedural antiplatelet use with decreased thromboembolic complications for intracranial aneurysms undergoing intrasaccular flow disruption

Journal of Neurosurgery | May 3, 2024 | Volume: 141 | Issue: 4 | Pages: 992-999

10.3171/2024.2.jns232918 | PMID 38701528

OBJECTIVE This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19–0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25–0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38–10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26–8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04–0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48–230, p = 0.024). CONCLUSIONS The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.