Citations 49

Future clinical medical physics division should have fewer medical physicists and more medical physics assistants

Journal of Applied Clinical Medical Physics | December 2, 2024 | Volume: 26 | Issue: 1 | Pages: No page available

10.1002/acm2.14592 | PMID 39620657

Promotion and tenure for medical physicists should be based on article specific measures and not on journal impact factor

Journal of Applied Clinical Medical Physics | October 10, 2024 | Volume: 25 | Issue: 12 | Pages: No page available

10.1002/acm2.14537 | PMID 39387823

Comprehensive clinical implementation, workflow, and FMEA of bespoke silicone bolus cast from 3D printed molds using open‐source resources

Journal of Applied Clinical Medical Physics | August 27, 2024 | Volume: 25 | Issue: 11 | Pages: No page available

10.1002/acm2.14498 | PMID 39189817

AbstractBackgroundBolus materials have been used for decades in radiotherapy. Most frequently, these materials are utilized to bring dose closer to the skin surface to cover superficial targets optimally. While cavity filling, such as nasal cavities, is desirable, traditional commercial bolus is lacking, requiring other solutions. Recently, investigators have worked on utilizing 3D printing technology, including commercially available solutions, which can overcome some challenges with traditional bolus.PurposeTo utilize failure modes and effects analysis (FMEA) to successfully implement a comprehensive 3D printed bolus solution to replace commercial bolus in our clinic using a series of open‐source (or free) software products.Methods3D printed molds for bespoke bolus were created by exporting the DICOM structures of the bolus designed in the treatment planning system and manipulated to create a multipart mold for 3D printing. A silicone (Ecoflex 00–30) mixture is poured into the mold and cured to form the bolus. Molds for sheet bolus of five thicknesses were also created. A comprehensive FMEA was performed to guide workflow adjustments and QA steps.ResultsThe process map identified 39 and 30 distinct steps for the bespoke and flat sheet bolus workflows, respectively. The corresponding FMEA highlighted 119 and 86 failure modes, with 69 shared between the processes. Misunderstanding of plan intent was a potential cause for most of the highest‐scoring failure modes, indicating that physics and dosimetry involvement early in the process is paramount.ConclusionFMEA informed the design and implementation of QA steps to guarantee a safe and high‐quality comprehensive implementation of silicone bolus from 3D printed molds. This approach allows for greater adaptability not afforded by traditional bolus, as well as potential dissemination to other clinics due to the open‐source nature of the workflow.
Evaluation of knowledge‐based planning models for male pelvic CBCT‐based online adaptive radiotherapy on conventional linear accelerators

Journal of Applied Clinical Medical Physics | July 20, 2024 | Volume: 25 | Issue: 9 | Pages: No page available

10.1002/acm2.14464 | PMID 39031902

AbstractPurposeTo assess the practicality of employing a commercial knowledge‐based planning tool (RapidPlan) to generate adapted intact prostate and prostate bed volumetric modulated arc therapy (VMAT) plans on iterative cone‐beam computed tomography (iCBCT) datasets.Methods and materialsIntact prostate and prostate bed RapidPlan models were trained utilizing planning data from 50 and 44 clinical cases, respectively. To ensure that refined models were capable of producing adequate clinical plans with a single optimization, models were tested with 50 clinical planning CT datasets by comparing dose‐volume histogram (DVH) and plan quality metric (PQM) values between clinical and RapidPlan‐generated plans. The RapidPlan tool was then used to retrospectively generate adapted VMAT plans on daily iCBCT images for 20 intact prostate and 15 prostate bed cases. As before, DVH and PQM metrics were utilized to dosimetrically compare scheduled (iCBCT Verify) and adapted (iCBCT RapidPlan) plans. Timing data was collected to further evaluate the feasibility of integrating this approach within an online adaptive radiotherapy workflow.ResultsModel testing results confirmed the models were capable of producing VMAT plans within a single optimization that were overall improved upon or dosimetrically comparable to original clinical plans. Direct application of RapidPlan on iCBCT datasets produced satisfactory intact prostate and prostate bed plans with generally improved target volume coverage/conformality and rectal sparing relative to iCBCT Verify plans as indicated by DVH values, though bladder metrics were marginally increased on average. Average PQM values for iCBCT RapidPlans were significantly improved compared to iCBCT Verify plans. The average time required [in mm:ss] to generate adapted plans was 06:09 ± 02:06 (intact) and 07:12 ± 01:04 (bed).ConclusionThis study demonstrated the feasibility of leveraging RapidPlan to expeditiously generate adapted VMAT intact prostate and prostate bed plans on iCBCT datasets. In general, adapted plans were dosimetrically improved relative to scheduled plans, emphasizing the practicality of the proposed approach.
Deformable dose accumulation is required for adaptive radiotherapy practice

Journal of Applied Clinical Medical Physics | July 19, 2024 | Volume: 25 | Issue: 8 | Pages: No page available

10.1002/acm2.14457 | PMID 39031438

Testing and Validation of a Custom Retrained Large Language Model for the Supportive Care of HN Patients with External Knowledge Base

Cancers | June 24, 2024 | Volume: 16 | Issue: 13 | Pages: 2311

10.3390/cancers16132311 | PMID 39001375

Purpose: This study aimed to develop a retrained large language model (LLM) tailored to the needs of HN cancer patients treated with radiotherapy, with emphasis on symptom management and survivorship care. Methods: A comprehensive external database was curated for training ChatGPT-4, integrating expert-identified consensus guidelines on supportive care for HN patients and correspondences from physicians and nurses within our institution’s electronic medical records for 90 HN patients. The performance of our model was evaluated using 20 patient post-treatment inquiries that were then assessed by three Board certified radiation oncologists (RadOncs). The rating of the model was assessed on a scale of 1 (strongly disagree) to 5 (strongly agree) based on accuracy, clarity of response, completeness s, and relevance. Results: The average scores for the 20 tested questions were 4.25 for accuracy, 4.35 for clarity, 4.22 for completeness, and 4.32 for relevance, on a 5-point scale. Overall, 91.67% (220 out of 240) of assessments received scores of 3 or higher, and 83.33% (200 out of 240) received scores of 4 or higher. Conclusion: The custom-trained model demonstrates high accuracy in providing support to HN patients offering evidence-based information and guidance on their symptom management and survivorship care.
The history of the JACMP debate series

Journal of Applied Clinical Medical Physics | June 23, 2024 | Volume: 25 | Issue: 7 | Pages: No page available

10.1002/acm2.14446 | PMID 38922801

Resolving signal drift in the wall‐mounted camera of the RGSC system

Journal of Applied Clinical Medical Physics | February 2, 2024 | Volume: 25 | Issue: 3 | Pages: No page available

10.1002/acm2.14291 | PMID 38306504

AbstractPurposeTo present a modified calibration method to reduce signal drift due to table sagging in Respiratory Gating for Scanner (RGSC) systems with a wall‐mounted camera.Materials and MethodsApproximately 70 kg of solid water phantoms were evenly distributed on the CT couch, mimicking the patient's weight. New calibration measurements were performed at 9 points at the combination of three lateral positions, the CT isocenter and ±10 cm laterally from the isocenter, and three longitudinal locations, the CT isocenter and ±30 cm or ±40 cm from the isocenter. The new calibration was tested in two hospitals.ResultsImplementing the new weighed calibration method at the extended distance yielded improved results during the DIBH scan, reducing the drift to within 1 from 3 mm. The extended calibration positions exhibited similarly reduced drift in both hospitals, reinforcing the method's robustness and its potential applicability across all centers.ConclusionThis proposed solution aims to minimize the systematic error in radiation delivery for patients undergoing motion management with wall‐mounted camera RGSC systems, especially in conjunction with a bariatric CT couchtop.
Contour subregion error detection methodology using deep learning auto‐segmentation

Medical Physics | October 4, 2023 | Volume: 50 | Issue: 11 | Pages: 6673-6683

10.1002/mp.16768 | PMID 37793103

AbstractBackgroundInaccurate manual organ delineation is one of the high‐risk failure modes in radiation treatment. Numerous automated contour quality assurance (QA) systems have been developed to assess contour acceptability; however, manual inspection of flagged cases is a time‐consuming and challenging process, and can lead to users overlooking the exact error location.PurposeOur aim is to develop and validate a contour QA system that can effectively detect and visualize subregional contour errors, both qualitatively and quantitatively.Methods/MaterialsA novel contour subregion error detection (CSED) system was developed using subregional surface distance discrepancies between manual and deep learning auto‐segmentation (DLAS) contours. A validation study was conducted using a head and neck public dataset containing 339 cases and evaluated according to knowledge‐based pass criteria derived from a clinical training dataset of 60 cases. A blind qualitative evaluation was conducted, comparing the results from the CSED system with manual labels. Subsequently, the CSED‐flagged cases were re‐examined by a radiation oncologist.ResultsThe CSED system could visualize the diverse types of subregional contour errors qualitatively and quantitatively. In the validation dataset, the CSED system resulted in true positive rates (TPR) of 0.814, 0.800, and 0.771; false positive rates (FPR) of 0.310, 0.267, and 0.298; and accuracies of 0.735, 0.759, and 0.730, for brainstem and left and right parotid contours, respectively. The CSED‐assisted manual review caught 13 brainstem, 19 left parotid, and 21 right parotid contour errors missed by conventional human review. The TPR/FPR/accuracy of the CSED‐assisted manual review improved to 0.836/0.253/0.784, 0.831/0.171/0.830, and 0.808/0.193/0.807 for each structure, respectively. Further, the time savings achieved through CSED‐assisted review improved by 75%, with the time for review taking 24.81 ± 12.84, 26.75 ± 10.41, and 28.71 ± 13.72 s for each structure, respectively.ConclusionsThe CSED system enables qualitative and quantitative detection, localization, and visualization of manual segmentation subregional errors utilizing DLAS contours as references. The use of this system has been shown to help reduce the risk of high‐risk failure modes resulting from inaccurate organ segmentation.
Physicists should perform reference planning for CBCT guided online adaptive radiotherapy

Journal of Applied Clinical Medical Physics | September 30, 2023 | Volume: 24 | Issue: 10 | Pages: No page available

10.1002/acm2.14163 | PMID 37776261