Citations 47

The Detection of Human Papillomavirus Deoxyribonucleic Acid in Intraepithelial, in Situ, Verrucous and Invasive Carcinoma of the Penis

Journal of Urology | January 17, 2006 | Volume: 154 | Issue: 3 | Pages: 1024-1029

10.1016/s0022-5347(01)66967-2

Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing

Clinical Microbiology Reviews | January 17, 2006 | Volume: 19 | Issue: 1 | Pages: 165-256

10.1128/cmr.19.1.165-256.2006 | PMID 16418529

SUMMARY Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory.
Sequencing and Resolution of Amplified Herpes Simplex Virus DNA with Intermediate Melting Curves as Genotype 1 or 2 by LightCycler PCR Assay

Journal of Clinical Microbiology | April 6, 2005 | Volume: 43 | Issue: 4 | Pages: 1843-1845

10.1128/jcm.43.4.1843-1845.2005 | PMID 15815006

ABSTRACT DNA from 101 specimens containing herpes simplex virus (HSV) produced atypical intermediate melting curves compared with those expected for HSV type 1 or HSV type 2 subsequent to real-time PCR. Nucleic acid sequence analysis of amplified target DNA revealed 1- or 3-bp polymorphisms in the probe region which allowed designation of these viruses as HSV genotype 1 or HSV genotype 2. These two subpopulations of HSV were also identified as HSV genotype 1 or HSV genotype 2 using another commercially available PCR method. Amplified HSV target DNA producing intermediate melting curves could be designated as HSV genotype 1 or HSV genotype 2 without performing sequencing or another PCR method with 96/101 (95%) specimens by adding known intermediate HSV DNA characteristic for the two subpopulations as controls.
Comparison of Specimen Processing and Nucleic Acid Extraction by the Swab Extraction Tube System versus the MagNA Pure LC System for Laboratory Diagnosis of Herpes Simplex Virus Infections by LightCycler PCR

Journal of Clinical Microbiology | March 4, 2005 | Volume: 43 | Issue: 3 | Pages: 1059-1063

10.1128/jcm.43.3.1059-1063.2005 | PMID 15750060

ABSTRACT A total of 563 specimens (234 dermal and 329 genital swabs) from patients suspected of having herpes simplex virus (HSV) infections were processed using two different extraction methods (the MagNA Pure LC system and the swab extraction tube system [SETS]); HSV DNA was amplified by LightCycler PCR. HSV DNA was detected in 157 of 563 specimens (27.9%) processed by the MagNA Pure LC system and in 179 of 563 specimens (31.8%) processed by SETS ( P < 0.0001). There was no specimen processed by the MagNA Pure LC extraction method that was positive only for HSV DNA. Of 157 specimens positive by both methods, HSV DNA copy levels were higher (using cycle crossover points [cycle threshold { C T }]) with SETS (mean C T , 25.9 cycles) than with the MagNA Pure LC system (mean C T , 32.0 cycles) ( P < 0.0001). The time to process 32 samples was longer with the MagNA Pure LC extraction system (90 min) than with SETS (35 min). HSV DNA extraction using SETS is faster, less expensive, and more sensitive than the MagNA Pure LC system and could replace the latter for the laboratory diagnosis of HSV infections using LightCycler PCR.
Detection of Smallpox Virus DNA by LightCycler PCR

Journal of Clinical Microbiology | July 27, 2002 | Volume: 40 | Issue: 6 | Pages: 1985-1988

10.1128/jcm.40.6.1985-1988.2002 | PMID 12037052

ABSTRACT A 300-bp plasmid fragment of the hemagglutinin gene was used as target DNA to develop a rapid real-time LightCycler (Roche Applied Science, Indianapolis, Ind.) PCR assay for laboratory detection of smallpox virus. PCR primers and probes were designed specifically for detection of smallpox virus DNA, but all viruses of the genus Orthopoxvirus tested could be detected by use of the hemagglutinin gene target sequence. Base pair mismatches in the 204-bp amplicon allowed discrimination of cowpox virus (melting temperature [ T m ], 56.40°C), monkeypox virus ( T m , 56.24°C), and vaccinia virus ( T m , 56.72°C), including the Dryvax vaccine strain, from smallpox virus ( T m , 62.45°C) by melting curve analysis. The analytical sensitivity was 5 to 10 copies of target DNA per sample. The assay was specific for members of the genus Orthopoxvirus ; the DNAs of herpes simplex virus and varicella-zoster virus were not detected by the smallpox virus LightCycler PCR.
Comparative Quantitation of Cytomegalovirus (CMV) DNA in Solid Organ Transplant Recipients with CMV Infection by Using Two High-Throughput Automated Systems

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4472-4476

10.1128/jcm.39.12.4472-4476.2001 | PMID 11724864

ABSTRACT Cytomegalovirus (CMV) DNA quantitation in clinical specimens is progressively becoming a cornerstone in the diagnosis and management of CMV infection in the immunocompromised host. We evaluated two automated and reproducible PCR tests, the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.) and the COBAS AMPLICOR CMV Monitor (Roche Diagnostics, Pleasanton, Calif.), for the detection of CMV DNA in blood samples from transplant recipients with CMV infection as determined by shell vial culture. Following a log transformation analysis, the mean CMV DNA in plasma (PL), whole blood (WB), peripheral blood leukocytes (PBL), and peripheral blood mononuclear cells (PBMC) using the LightCycler was 6.79 copies per ml, 7.23 copies per ml, 6.38 copies per 2 × 10 6 cells, and 6.27 copies per 2 × 10 6 cells, respectively. This compares to 7.86 copies per ml, 8.37 copies per ml, 7.59 copies per 2 × 10 6 cells, and 7.44 copies per 2 × 10 6 cells, respectively, using COBAS AMPLICOR CMV Monitor. While higher CMV DNA levels were observed for the various blood compartments analyzed using COBAS AMPLICOR CMV Monitor, a high degree of correlation was evident between the two automated systems (jackknife correlation r = PL 0.77 [95% confidence interval (CI); 0.64, 0.90], WB 0.77 [95% CI; 0.62, 0.92], PBL 0.77 [95% CI; 0.67, 0.88], and PBMC 0.81 [95% CI; 0.72, 0.89], all P < 0.001). Therefore, we conclude that either automated diagnostic system is accurate for CMV DNA quantitation.
Detection of Herpes Simplex Virus DNA in Genital and Dermal Specimens by LightCycler PCR after Extraction using the IsoQuick, MagNA Pure, and BioRobot 9604 Methods

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 6 | Pages: 2233-2236

10.1128/jcm.39.6.2233-2236.2001 | PMID 11376062

ABSTRACT We evaluated two automated systems, MagNA Pure (Roche Molecular Biochemicals, Indianapolis, Ind.) and BioRobot 9604 (Qiagen, Inc., Chatsworth, Calif.) as effective replacements for the manual IsoQuick method (Orca Research, Inc., Bothell, Wash.) for extraction of herpes simplex virus (HSV) DNA from dermal and genital tract specimens prior to analysis by LightCycler PCR. Of 198 specimens (152 genital, 46 dermal), 92 (46.2%) were positive for HSV DNA by LightCycler PCR after automated extraction of specimens with either the MagNA Pure or BioRobot 9604 instrument. The manual IsoQuick method yielded HSV DNA (total n = 95) from three additional specimens that were negative by the automated method ( P = 0.25, sign test). Although the mean numbers of LightCycler PCR cycles required to reach positivity differed statistically significantly among all three of the methods of extraction, the estimated means differed by no more than 1.5 cycles ( P < 0.05). Seventy (76%) of the 92 specimens that were LightCycler PCR positive by all three extraction methods were also positive by shell vial cell culture assay. HSV DNA was detected by a lower LightCycler PCR cycle number (26.1 cycles) in specimens culture positive for the virus than in culture-negative samples (33.3 cycles) ( P < 0.0001). The manual IsoQuick and automated MagNA Pure and BioRobot 9604 methods provide standardized, reproducible extraction of HSV DNA for LightCycler PCR. The decision to implement a manual versus an automated procedure depends on factors such as costs related to the number of specimens processed rather than on the minimal differences in the technical efficiency of extraction of nucleic acids among these methods.