Citations 30

Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities

Magnetic Resonance in Medicine | March 15, 2018 | Volume: 80 | Issue: 5 | Pages: 2232-2245

10.1002/mrm.27175 | PMID 29536587

PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
Time‐resolved contrast‐enhanced MR angiography with single‐echo Dixon fat suppression

Magnetic Resonance in Medicine | February 28, 2018 | Volume: 80 | Issue: 4 | Pages: 1556-1567

10.1002/mrm.27152 | PMID 29488251

PurposeDixon‐based fat suppression has recently gained interest for dynamic contrast‐enhanced MRI, but multi‐echo techniques require longer scan times and reduce temporal resolution compared to single‐echo alternatives without fat suppression. The purpose of this work is to demonstrate accelerated single‐echo Dixon imaging with high spatial and temporal resolution.Theory and MethodsReal‐valued water and fat images can be obtained from a single measurement if the shared initial phase and that due to are assumed known a priori. An expression for simultaneous sensitivity encoding (SENSE) unfolding and fat‐water separation is derived for the general undersampling case, and simplified under the special case of uniform Cartesian undersampling. In vivo experiments were performed in extremities and brain with SENSE acceleration factors of up to R = 8.ResultsSingle‐echo Dixon reconstruction of highly undersampled data was successfully demonstrated. Dynamic contrast‐enhanced water and fat images provided high spatial and temporal resolution dynamic images with image update times shorter than previous single‐echo Dixon work.ConclusionTime‐resolved contrast‐enhanced MRI with single‐echo Dixon fat suppression shows high image quality, improved vessel delineation, and reduced sensitivity to motion when compared to time‐subtraction methods.
CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection

Acta Radiologica Open | November 27, 2017 | Volume: 6 | Issue: 11 | Pages: 205846011774327

10.1177/2058460117743279 | PMID 29225924

Background Dental hardware produces streak artifacts on computed tomography (CT) images reconstructed with the standard weighted filtered back projection (wFBP) method. Purpose To perform a preliminary evaluation of an iterative metal artifact reduction (IMAR) technique to assess its ability to improve anatomic visualization over wFBP in patients with dental amalgam or other hardware. Material and Methods CT images from patients with dental hardware were reconstructed using wFBP and IMAR software and soft-tissue or bone window/level settings. The anatomy most affected by metal artifacts was identified. Two neuroradiologists determined subjective and objective imaging features, including overall metal artifact score (1 = severe artifacts, 5 = no artifacts), soft-tissue visualization score of the most-compromised structure, and artifact length along the skin surface. CT numbers were used to quantify artifact severity. Results Twenty-four patients were included. IMAR improved overall metal artifact score in 18/24 cases (median =2 ± 0.9 vs. 1 ± 0.6, P < 0.001). Mean CT number in the most-affected anatomical structure significantly improved with IMAR (94.6 vs. 219 HU, P = 0.002) and length of affected skin surface decreased (40.4 mm vs. 118.7 mm, P < 0.001). However, osseous/dental artifactual defects were found in 22/24 cases with IMAR vs. 11/24 with wFBP. Conclusion IMAR software reduced metal artifact both subjectively and objectively and improved visualization of adjacent soft tissues. However, it produced a higher rate of artifactual defects in the teeth and bones than wFBP. Our findings support the use of IMAR as a valuable complement to, but not a replacement for, standard wFBP image reconstruction.
Image Registration Improves Confidence and Accuracy of Image Interpretation

Cancer Informatics | October 4, 2017 | Volume: 4 | Issue: No issue available | Pages: 117693510700400

10.1177/117693510700400004

Dual-Energy CT Differentiates Contrast Staining From Hemorrhagic Conversion of Ischemic Stroke

The Neurohospitalist | April 16, 2017 | Volume: 8 | Issue: 1 | Pages: 42-43

10.1177/1941874417704754 | PMID 29276564

Evaluation of Suspected Aspirated Beverage Can Pull Tab: Radiographs May Not Be Enough

Case Reports in Radiology | December 14, 2014 | Volume: 2014 | Issue: No issue available | Pages: 1-3

10.1155/2014/196960 | PMID 25580344

A 67-year-old male presented to the emergency department with concern for accidental aspiration of an aluminum beverage can pull tab. Neck and chest radiographs did not reveal an aspirated foreign body. Despite ongoing complaint of dysgeusia and adamancy of aspiration by the patient, he was discharged to home without recommendation for further follow-up. Seven months later, a computed tomography (CT) scan of the chest performed as part of an unrelated lung cancer work up confirmed the presence of a left mainstem bronchus metallic foreign body compatible with a pull tab. This case report illustrates the poor negative predictive value of radiographs for a suspected aluminum foreign body and demonstrates the superiority of CT for this purpose. In such presentations it is imperative to have a low threshold for performing further diagnostic evaluation with CT due to the relatively high radiolucency of aluminum.
Pearls & Oy-sters: Good recovery following cerebral fat embolization with paroxysmal hyperactivity syndrome

Neurology | October 1, 2013 | Volume: 81 | Issue: 14 | Pages: No page available

10.1212/wnl.0b013e3182a6ca3e | PMID 24081967

Volumetric myelographic magnetic resonance imaging to localize difficult-to-find spinal dural arteriovenous fistulas

Journal of Neurosurgery: Spine | January 21, 2011 | Volume: 14 | Issue: 3 | Pages: 398-404

10.3171/2010.11.spine10328 | PMID 21250812

Although more prevalent in males in the 6th and 7th decade of life, spinal dural arteriovenous fistulas (SDAVFs) are an uncommon cause of progressive myelopathy. Magnetic resonance imaging and more recently Gd bolus MR angiography have been used to diagnose, radiographically define, and preprocedurally localize the contributing lumbar artery. Three-dimensional myelographic MR imaging sequences have recently been developed for anatomical evaluation of the spinal canal. The authors describe 3 recent cases in which volumetric myelographic MR imaging with a 3D phase-cycled fast imaging employing steady state acquisition (PC-FIESTA) and a 3D constructive interference steady state (CISS) technique were particularly useful not only for documenting an SDAVF, but also for providing localization when CT angiography, MR imaging, MR angiography, and spinal angiography failed to localize the fistula. In a patient harboring an SDAVF at T-4, surgical exploration was performed based on the constellation of findings on the PC-FIESTA images as well as the fact that the spinal segments leading to T-4 were the only ones that the authors were unable to catheterize. In a second patient, who harbored an SDAVF at T-6, after 2 separate angiograms failed to demonstrate the fistula, careful assessment of the CISS images led the authors to focus a third angiogram on the left T-6 intercostal artery and to perform superselective microcatheterization. In a third patient with an SDAVF originating from the lateral sacral branch, the PC-FIESTA sequence demonstrated the arterialized vein extending into the S-1 foramen, leading to a second angiogram and superselective internal iliac injections. The authors concluded that myelographic MR imaging sequences can be useful not only as an aid to diagnosis but also for localization of an SDAVF in complex cases.
Insidious sinusitis leading to catastrophic cerebral aspergillosis in transplant recipients

Neurology | June 9, 2008 | Volume: 70 | Issue: 24_part_2 | Pages: 2411-2413

10.1212/01.wnl.0000314690.18731.1b | PMID 18541875

The clinical challenge of recognizing infratentorial empyema

Neurology | July 30, 2007 | Volume: 69 | Issue: 5 | Pages: 477-481

10.1212/01.wnl.0000266631.19745.32 | PMID 17664407