Citations 52

A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 | PMID 35233867

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
Safety of catheter ablation in obese patients: Less complicated than you think

Journal of Cardiovascular Electrophysiology | February 4, 2022 | Volume: 33 | Issue: 4 | Pages: 664-666

10.1111/jce.15394 | PMID 35118744

Catheter ablation versus medical therapy for atrial fibrillation: Penny‐wise Pound‐foolish

Journal of Cardiovascular Electrophysiology | December 12, 2021 | Volume: 33 | Issue: 2 | Pages: 176-177

10.1111/jce.15316 | PMID 34897873

AbstractCatheter ablation for atrial fibrillation has emerged as a mainstay for the management of atrial fibrillation. It has been shown to be clinically effective and cost‐effective in multiple trials.
Catheter Ablation Versus Medical Therapy for Atrial Fibrillation - Penny wise Pound Foolish !

No container title available | December 4, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163864894.46936919/v1

Catheter ablation for atrial fibrillation has emerged as a main stay for management of atrial fibrillation. It has been shown to be clinically effective and cost effective in multiple trials .
A Real-world Experience of Atrioventricular Synchronous Pacing with Leadless Ventricular Pacemakers

No container title available | November 16, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163711930.05423871/v1

Aims: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are currently lacking. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. Methods: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous-ventricular pacing (AsVP) ≥70%. Results: Fifty-six percent of patients achieved AsVP ≥70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure and pulmonary hypertension. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were persistent atrial arrhythmias, small A4-wave amplitude, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. Conclusion: With the increasing popularity of leadless PM, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.
Incidence and Clinical Management of Atrial Arrhythmias in Patients with Catecholaminergic Polymorphic Ventricular Tachycardia

No container title available | September 25, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163255802.24375905/v1

Background: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a genetic arrhythmia syndrome characterized by adrenergically-triggered ventricular arrhythmias, syncope, and sudden cardiac death. Several small studies suggest that atrial arrhythmias (AAs) are common in patients with CPVT. Objective: To determine the incidence and type of AAs observed within a large, single-center cohort of CPVT cases as well as the efficacy and durability of AA-directed management. Methods: In this retrospective study, the electronic medical record of 129 patients (52% female; average age at diagnosis 20.8  15.3 years) with CPVT (95% with a putative CPVT1-causative RYR2 variant) between 01/2000 and 09/2019 were reviewed for electrocardiographic evidence of AAs. Clinical features and efficacy of pharmacologic and ablation therapy were assessed. Results: Overall, 10/129 (7.8%) CPVT patients, all RYR2 variant-positive, had evidence of an AA (atrial fibrillation/flutter in 6, atrial tachycardia in 3, and supraventricular tachycardia in 1). The median age at AA diagnosis was 23 (14.2-35.5) years. 8/10 of patients experienced symptoms attributed to their AA, including inappropriate shocks. All patients were trialed on anti-arrhythmics, including -blockers, and/or flecainide. Owing to drug failure (1/10), drug intolerance (1/10), or patient preference (2/10); 4/10 patients received an ablation. Over a median follow-up of 23.5 (4.5-63) months, no AA recurrences were observed. Conclusion: Compared to prior studies, the incidence of AAs in this large, single-center referral cohort of CPVT patients was substantially lower (7.8% vs. 26%-35%). Although larger multi-center studies are needed to confirm, this study suggests that ablation is efficacious and durable in CPVT-associated AAs.
Efficacy of intentional permanent atrial pacing in the long‐term management of congenital long QT syndrome

Journal of Cardiovascular Electrophysiology | January 29, 2021 | Volume: 32 | Issue: 3 | Pages: 782-789

10.1111/jce.14920 | PMID 33512040

AbstractBackgroundUnfortunately, some patients with long QT syndrome (LQTS) experience breakthrough cardiac events (BCEs) despite maximal therapy. Small studies have shown that refractory LQTS cases may benefit from intentional permanent atrial pacing (IPAP). As such, we sought to determine the genotype‐specific utilization and efficacy of IPAP in a single‐center LQTS registry.Methods and ResultsIn this retrospective study, electronic medical records from 1065 patients diagnosed with LQTS were used to identify individuals that received IPAP. Pre‐ and post‐IPAP heart rate, heart rate‐corrected QT (QTc) values, annual BCE rate, and IPAP‐related complications were compared between genotypes. BCEs were defined as LQTS‐associated syncope/seizures, sustained ventricular arrhythmia (VA)‐terminating ICD therapies, and sudden cardiac arrest/death.Overall, 52 out of 1065 LQTS patients received adjunctive IPAP therapy (77% female; median age 18.5 [interquartile range, 1–35.5] years; 73% with prior VA). Over an average IPAP follow‐up of 121 ± 82 months, the average heart rate increased from 65.8 ± 20.4 bpm to 78.9 ± 17.1 bpm; (p < .01) and the average QTc decreased from 533.4 ± 66.6 to 488.3 ± 52.4 ms; (p < .01). The mean BCE rate dropped from 0.88 to 0.19 per patient‐year (p = .01), driven by a marked decrease in the LQT2 cohort (1.01 BCE/year to 0.02 BCE/year; p = .003). No serious IPAP‐related complications were observed.ConclusionIn high‐risk LQTS patients, namely those with recalcitrant LQT2, IPAP appears to be a safe and efficacious adjunct therapy. The beneficial effects of IPAP may stem from attenuating the QTc and circumventing a pause‐dependent trigger. Whether IPAP might obviate the need for an ICD in some instances warrants further study.
Quadricuspid Aortic Valve: A Case Report and Review of Literature

Future Cardiology | January 19, 2021 | Volume: 17 | Issue: 5 | Pages: 833-840

10.2217/fca-2020-0135 | PMID 33463363

Sound wave balloon-assisted device implantation: a novel approach that merits consideration

EP Europace | November 19, 2020 | Volume: 23 | Issue: 5 | Pages: 747-747

10.1093/europace/euaa281 | PMID 33582813

Management of ventricular electrical storm: a contemporary appraisal

EP Europace | July 15, 2020 | Volume: 22 | Issue: 12 | Pages: 1768-1780

10.1093/europace/euaa232 | PMID 32984880

Abstract Ventricular electrical storm (VES) is a clinical scenario characterized by the clustering of multiple episodes of sustained ventricular arrhythmias (VA) over a short duration. Patients with VES are prone to psychological disorders, heart failure decompensation, and increased mortality. Studies have shown that 10–28% of the patients with secondary prevention ICDs can sustain VES. The triad of a susceptible electrophysiologic substrate, triggers, and autonomic dysregulation govern the pathogenesis of VES. The rate of VA, underlying ventricular function, and the presence of implantable cardioverter-defibrillator (ICD) determine the clinical presentation. A multi-faceted approach is often required for management consisting of acute hemodynamic stabilization, ICD reprogramming when appropriate, antiarrhythmic drug therapy, and sedation. Some patients may be eligible for catheter ablation, and autonomic modulation with thoracic epidural anesthesia, stellate ganglion block, or cardiac sympathetic denervation. Hemodynamically unstable patients may benefit from the use of left ventricular assist devices, and extracorporeal membrane oxygenation. Special scenarios such as idiopathic ventricular fibrillation, Brugada syndrome, Long and short QT syndrome, early repolarization syndrome, catecholaminergic polymorphic ventricular tachycardia, arrhythmogenic right ventricular cardiomyopathy, and cardiac sarcoidosis have been described as well. VES is a cardiac emergency that requires swift intervention. It is associated with poor short and long-term outcomes. A structured team-based management approach is paramount for the safe and effective treatment of this sick cohort.