Citations 24

Diagnosis of Prosthetic Joint Infection by Use of PCR-Electrospray Ionization Mass Spectrometry

Journal of Clinical Microbiology | November 28, 2013 | Volume: 52 | Issue: 2 | Pages: 642-649

10.1128/jcm.03217-13 | PMID 24478503

ABSTRACT We compared PCR-electrospray ionization mass spectrometry (PCR-ESI/MS) to culture using sonicate fluid from 431 subjects with explanted knee ( n = 270) or hip ( n = 161) prostheses. Of these, 152 and 279 subjects had prosthetic joint infection (PJI) and aseptic failure, respectively. The sensitivities for detecting PJI were 77.6% for PCR-ESI/MS and 69.7% for culture ( P = 0.0105). The specificities were 93.5 and 99.3%, respectively ( P = 0.0002).
Detection and Identification of Yeasts from Formalin-Fixed, Paraffin-Embedded Tissue by Use of PCR-Electrospray Ionization Mass Spectrometry

Journal of Clinical Microbiology | August 29, 2013 | Volume: 51 | Issue: 11 | Pages: 3731-3734

10.1128/jcm.01967-13 | PMID 23985922

ABSTRACT Diagnosis of yeast infection is typically accomplished by fungal smear and culture, histopathologic examination, and/or serologic studies. Newer assays based on mass spectrometry may be useful for yeast identification when histologic examination is inconclusive, fungal cultures are not ordered, or cultures fail to yield a causative agent. The purpose of this study was to evaluate the ability of the PLEX-ID broad fungal assay to accurately detect and identify yeasts in formalin-fixed paraffin-embedded (FFPE) tissues. Tissue samples from 78 FFPE specimens with both histopathology and corresponding culture results for a variety of yeasts were tested using the PLEX-ID broad fungal assay. A 40-μm FFPE tissue section from each specimen was digested with proteinase K followed by nucleic acid extraction and PCR using broad-range fungal primers. Yeast DNA in amplified products was identified using electrospray ionization mass spectrometry. Discordant results were resolved by D2 rRNA gene sequencing. PLEX-ID analysis detected yeast DNA in 78.2% (61/78) of the cases, of which 91.8% (56/61) were concordant with culture results. Of the 5 discordant positive results, 4 PLEX-ID results were considered to result from environmental contaminants, while 1 clinically important discrepancy was observed ( Blastomyces dermatitidis by culture and Cryptococcus neoformans by PLEX-ID). Sequencing of the discordant sample was unsuccessful. The majority of histopathology results (89.7% [70/78]) correlated with culture results. The PLEX-ID broad fungal assay identifies fungi directly from FFPE tissues and can be a useful adjunct to traditional culture and histopathology tests.
Identification of Mycobacterium Species and Mycobacterium tuberculosis Complex Resistance Determinants by Use of PCR-Electrospray Ionization Mass Spectrometry

Journal of Clinical Microbiology | August 15, 2013 | Volume: 51 | Issue: 11 | Pages: 3492-3498

10.1128/jcm.01408-13 | PMID 23946518

ABSTRACT PCR coupled with electrospray ionization mass spectrometry (PCR–ESI-MS) is a novel technology that has recently been used to identify pathogens from clinical specimens or after culture within about 6 h. We evaluated the MDR-TB (multidrug-resistant tuberculosis) assay, which uses PCR–ESI-MS for detection and identification of Mycobacterium spp. and Mycobacterium tuberculosis complex (MTBC) resistance determinants from solid and broth Middlebrook culture media. The performance of the MDR-TB assay was compared to identification using nucleic acid hybridization probes and 16S rRNA gene sequencing for 68 MTBC and 97 nontuberculous mycobacterial (NTM) isolates grown on agar and 107 cultures grown in Bactec MGIT broth. MTBC resistance profiles from the MDR-TB assay were compared to results with the agar proportion method. The PCR–ESI-MS system correctly identified all MTBC isolates and 97.9% and 95.8% of the NTM isolates from characterized agar cultures and MGIT broth cultures to the species level, respectively. In comparison to the agar proportion method, the sensitivity and specificity for the detection of drug resistance using the MDR-TB assay were 100% and 92.3% for rifampin, 100% and 93.8% for isoniazid, 91.6% and 94.4% for ethambutol, and 100% and 100% for fluoroquinolones, respectively. The MDR-TB assay appears to be a rapid and accurate method for the simultaneous detection and identification of mycobacterial species and resistance determinants of MTBC from culture.
PCR-Electrospray Ionization Mass Spectrometry for Direct Detection of Pathogens and Antimicrobial Resistance from Heart Valves in Patients with Infective Endocarditis

Journal of Clinical Microbiology | April 18, 2013 | Volume: 51 | Issue: 7 | Pages: 2040-2046

10.1128/jcm.00304-13 | PMID 23596241

ABSTRACT Microbiological diagnosis is pivotal to the appropriate management and treatment of infective endocarditis. We evaluated PCR-electrospray ionization mass spectrometry (PCR/ESI-MS) for bacterial and candidal detection using 83 formalin-fixed paraffin-embedded heart valves from subjects with endocarditis who had positive valve and/or blood cultures, 63 of whom had positive valvular Gram stains. PCR/ESI-MS yielded 55% positivity with concordant microbiology at the genus/species or organism group level (e.g., viridans group streptococci), 11% positivity with discordant microbiology, and 34% with no detection. PCR/ESI-MS detected all antimicrobial resistance encoded by mecA or vanA / B and identified a case of Tropheryma whipplei endocarditis not previously recognized.
Broad-Range Direct Detection and Identification of Fungi by Use of the PLEX-ID PCR-Electrospray Ionization Mass Spectrometry (ESI-MS) System

Journal of Clinical Microbiology | March 21, 2013 | Volume: 51 | Issue: 6 | Pages: 1699-1706

10.1128/jcm.03282-12 | PMID 23515540

ABSTRACT The PLEX-ID system is a novel technology that couples PCR amplification and electrospray ionization-mass spectrometry to identify pathogens directly in clinical specimens. The analytical performance of the PLEX-ID Broad Fungal assay was compared with that of traditional culture identification by using 91 characterized fungal culture isolates (64 manufacturer-claimed and 27 nonclaimed organisms) and directly by using 395 respiratory specimens. Discordant results were resolved by D2 large-subunit ribosomal DNA fungal sequencing. Environmental studies were performed to monitor for potential contamination. The PLEX-ID Broad Fungal assay correctly identified 95.6% (87/91) and 81.3% (74/91) of the culture isolates to the genus and species levels, respectively. Of the manufacturer-claimed organisms, 100% (64/64) and 92.2% (59/64) were correctly identified to the genus and species levels, respectively. Direct analysis of respiratory specimens resulted in 67.6% (267/395) and 66.6% (263/395) agreement with culture results to the genus and species levels, respectively, with 16.2% (64/395) of the results discordant with culture and 16.2% (64/395) not detected by the system. The majority (>95%) of the isolates not detected directly by the PLEX-ID system ultimately grew in low quantities in culture (≤20 colonies). In 20.3% (35/172) of the respiratory specimens where no growth was observed in culture, the PLEX-ID system identified a fungus, suggesting a potential increase in sensitivity over culture in some instances. The PLEX-ID system provides a rapid method for the detection of a broad array of fungi directly in respiratory specimens and has the potential of impacting turnaround times and patient care by reducing the need to wait for the growth of an organism in culture.
Prosthetic Joint Infection Diagnosis Using Broad-Range PCR of Biofilms Dislodged from Knee and Hip Arthroplasty Surfaces Using Sonication

Journal of Clinical Microbiology | August 16, 2012 | Volume: 50 | Issue: 11 | Pages: 3501-3508

10.1128/jcm.00834-12 | PMID 22895042

ABSTRACT Periprosthetic tissue and/or synovial fluid PCR has been previously studied for prosthetic joint infection (PJI) diagnosis; however, few studies have assessed the utility of PCR on biofilms dislodged from the surface of explanted arthroplasties using vortexing and sonication (i.e., sonicate fluid PCR). We compared sonicate fluid 16S rRNA gene real-time PCR and sequencing to culture of synovial fluid, tissue, and sonicate fluid for the microbiologic diagnosis of PJI. PCR sequences generating mixed chromatograms were decatenated using RipSeq Mixed. We studied sonicate fluids from 135 and 231 subjects with PJI and aseptic failure, respectively. Synovial fluid, tissue, and sonicate fluid culture and sonicate fluid PCR had similar sensitivities (64.7, 70.4, 72.6, and 70.4%, respectively; P > 0.05) and specificities (96.9, 98.7, 98.3, and 97.8%, respectively; P > 0.05). Combining sonicate fluid culture and PCR, the sensitivity was higher (78.5%, P < 0.05) than those of individual tests, with similar specificity (97.0%). Thirteen subjects had positive sonicate fluid culture but negative PCR, and 11 had negative sonicate fluid culture but positive PCR (among which 7 had prior use of antimicrobials). Broad-range PCR and culture of sonicate fluid have equivalent performance for PJI diagnosis.
Rapid Detection of Streptococcus pyogenes in Pleural Fluid Samples from Pediatric Patients with Empyema

Journal of Clinical Microbiology | May 24, 2012 | Volume: 50 | Issue: 8 | Pages: 2786-2787

10.1128/jcm.00603-12 | PMID 22622442

ABSTRACT A total of 120 pleural fluid specimens from 113 pediatric patients were tested using two rapid antigen detection assays for Streptococcus pyogenes . Results were compared to culture, Gram stain, and PCR results. Each rapid antigen assay detected 9 out of 10 (90%) PCR-positive samples, with 100% specificity. These antigen detection assays are useful to provide microbiological diagnosis of empyema caused by S. pyogenes .
Effect of Carbon Dioxide on Broth Microdilution Susceptibility Testing of Brucella spp

Journal of Clinical Microbiology | December 24, 2009 | Volume: 48 | Issue: 3 | Pages: 952-956

10.1128/jcm.01860-09 | PMID 20032255

ABSTRACT Since some strains of Brucella species may require carbon dioxide for growth, a multilaboratory study was conducted to compare broth microdilution susceptibility results using ambient air (AA) and 5% CO 2 incubation conditions. Six antimicrobial agents were tested against 39 Brucella isolates. Aminoglycoside MICs tended to be 1 log 2 dilution higher in CO 2 than in AA; tetracycline-class MICs to be 1 log 2 dilution lower in CO 2 .
Use of the Roche LightCycler Strep B Assay for Detection of Group B Streptococcus from Vaginal and Rectal Swabs

Journal of Clinical Microbiology | August 4, 2005 | Volume: 43 | Issue: 8 | Pages: 4046-4051

10.1128/jcm.43.8.4046-4051.2005 | PMID 16081949

ABSTRACT The results for a real-time PCR assay, using the LightCycler Strep B analyte-specific reagents (Roche Diagnostics Corporation, Indianapolis, Ind.), were compared to a direct plate method combined with a broth enrichment culture method for detection of group B streptococcus colonization in pregnant women. Two separate evaluations were conducted using two different automated nucleic extraction instruments, the MagNA Pure LC instrument (Roche Diagnostics Corporation) and the lower-capacity MagNA Pure Compact instrument (Roche Diagnostics Corporation). The sensitivities, specificities, and positive and negative predictive values for the different evaluation methods were as follow: for the LightCycler Strep B assay with MagNA Pure LC, 100, 97, 90, and 100%, respectively; for the LightCycler Strep B assay with MagNA Pure Compact, 92.5, 99, 97, and 97.5%, respectively. The LightCycler Strep B assay combined with either MagNA Pure LC or MagNA Pure Compact extraction is a suitable method for detecting group B streptococcus colonization in pregnant women. An advantage of the LightCycler assay over culture is the considerably reduced turnaround time for results.
Sequencing and Resolution of Amplified Herpes Simplex Virus DNA with Intermediate Melting Curves as Genotype 1 or 2 by LightCycler PCR Assay

Journal of Clinical Microbiology | April 6, 2005 | Volume: 43 | Issue: 4 | Pages: 1843-1845

10.1128/jcm.43.4.1843-1845.2005 | PMID 15815006

ABSTRACT DNA from 101 specimens containing herpes simplex virus (HSV) produced atypical intermediate melting curves compared with those expected for HSV type 1 or HSV type 2 subsequent to real-time PCR. Nucleic acid sequence analysis of amplified target DNA revealed 1- or 3-bp polymorphisms in the probe region which allowed designation of these viruses as HSV genotype 1 or HSV genotype 2. These two subpopulations of HSV were also identified as HSV genotype 1 or HSV genotype 2 using another commercially available PCR method. Amplified HSV target DNA producing intermediate melting curves could be designated as HSV genotype 1 or HSV genotype 2 without performing sequencing or another PCR method with 96/101 (95%) specimens by adding known intermediate HSV DNA characteristic for the two subpopulations as controls.