Abstract Purpose To determine the objective characteristics of fellowship directors (FDs) in orthopaedic sports medicine by focusing on the demographics, academic background, institutional history, research experience, and professional affiliations of FDs in this field. Methods Data was collected for each FD via institutional biographies or publicly available curriculum vitae (CV). The data collected for each FD included age, gender, race/ethnicity, previous training institutions, residency and fellowship graduation years, additional advanced degrees, military affiliation, institutional loyalty, year hired by current institution, career timeline, Scopus H‐index, number of publications, and total number of citations. Results Of the 88 FDs, 87 (98.9%) were male and 1 (1.1%) was female. The mean age for all FDs was 54.7 years (± 9.1 standard deviation). The majority of FDs were White (n = 80; 90.9%). The mean Scopus H‐index, total number of publications, and total number of citations were 22.5 ± 16.6, 90.0 ± 91.6, and 2773.9 ± 3962.9, respectively. On average, it took 9.5 ± 7.3 years from fellowship graduation until FD appointment. Additionally, the mean number of years of employment or affiliation with the current institution was 17.2 ± 9.4, and the mean number of years in an FD role was 10.9 ± 9.3. Conclusion Orthopaedic sports medicine fellowship directors are largely distinguished by their high level of research productivity and accomplishment. Additionally, orthopaedic training pedigree seems to play a role in FD role attainment, with a handful of orthopaedic residency and sports medicine fellowship programs producing a large percentage of current FDs. Finally, FDs are overwhelmingly white males with little female or minority representation. Clinical Relevance This study outlines some of the most important characteristics among orthopaedic sports medicine fellowship directors and identifies racial and gender disparities within this population of leaders that may have detrimental effects on the field as a whole.
Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques
The Bone & Joint Journal | May 31, 2021 | Volume: 103-B | Issue: 6 Supple A | Pages: 74-80
Aims Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA. Methods A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed. Results In all, 103 M-TKAs and 96 RA-TKAs were included. In RA-TKA versus M-TKA, respectively: mean femoral positioning (0.9° (SD 1.2°) vs 1.7° (SD 1.1°)), mean tibial positioning (0.3° (SD 0.9°) vs 1.3° (SD 1.0°)), mean posterior tibial slope (-0.3° (SD 1.3°) vs 1.7° (SD 1.1°)), and mean mechanical axis limb alignment (1.0° (SD 1.7°) vs 2.7° (SD 1.9°)) all deviated significantly less from the plan (all p < 0.001); significantly fewer knees required a distal femoral recut (10 (10%) vs 22 (22%), p = 0.033); and deviation from planned polyethylene thickness was significantly less (1.4 mm (SD 1.6) vs 2.7 mm (SD 2.2), p < 0.001). Conclusion RA-TKA is significantly more accurate and precise in planning both component positioning and final polyethylene insert thickness. Future studies should investigate whether this increased accuracy and precision has an impact on clinical outcomes. The greater accuracy and reproducibility of RA-TKA may be important as precise new goals for component positioning are developed and can be further individualized to the patient. Cite this article: Bone Joint J 2021;103-B(6 Supple A):74–80.
Is Labral Size Predictive of Failure With Repair in Hip Arthroscopy?
Purpose To assess whether labral size is predictive of labral repair failure or shows an association with patient outcomes after hip arthroscopy. Methods We performed a retrospective chart review of patients who underwent arthroscopic hip labral repair. Labral size was measured in 4 quadrants with an arthroscopic probe. The average size across torn labral segments was assessed for failure as determined by the change in patient‐reported outcomes, the rate at which subjects achieved the minimal clinically important difference and patient acceptable symptomatic state, and the need for additional surgery. Outcomes were evaluated for any continuous correlation as well as significant differences between the middle 50% of labral sizes and classes of labral sizes derived from upper and lower quartile and decile ranges. Included hips were those from patients aged between 18 and 55 years with 2‐year postoperative follow‐up and lateral center‐edge angles between 25° and 40°. Results The study included 571 hips. Labral width did not show a significant difference between hips requiring revision and those not requiring revision ( P = .4054). No significant correlation was found between labral width and the change in the International Hip Outcome Tool 12 score ( R 2 = 0.05780), modified Harris Hip Score ( R 2 = 0.19826), or Nonarthritic Hip Score ( R 2 = 0.23543) from preoperatively to 2 years postoperatively. Hips with labral sizes in the upper decile of our cohort showed significantly decreased improvement in the International Hip Outcome Tool 12 score ( P = .0287) and Nonarthritic Hip Score ( P = .0490) compared with the middle 50% of labral sizes. No statistically significant difference was found in the rate at which the groups achieved the minimal clinically important difference or patient acceptable symptomatic state. Conclusions Hypertrophic labra in the largest 10th percentile showed lower postoperative outcome scores. However, no detectable clinical benefit was found in terms of patient‐perceived clinical difference or acceptable symptomatic state. For most patients, labral size does not appear to significantly alter patient outcomes or the need for arthroplasty. Level of Evidence Level IV, retrospective case series.
Crystal Arthropathy in the Setting of Total Knee Arthroplasty
Case Reports in Orthopedics | March 24, 2020 | Volume: 2020 | Issue: No issue available | Pages: 1-4
We present a case of an 82-year-old female with a history of right total knee arthroplasty 11 years prior. She was admitted after a ground-level fall and developed progressive pain and swelling of her right knee. She had no history of complications with her total knee replacement. Radiographs of the knee and hip were negative for acute fracture, dislocation, or hardware malalignment. Knee aspiration was performed and revealed inflammatory exudate, synovial fluid consistent with crystal arthropathy, and no bacterial growth. She was diagnosed with an acute gout flare, and her symptoms significantly improved with steroids and anti-inflammatory treatment. Orthopedic surgeons should be aware of the potential for crystal arthropathy in the setting of total joint arthroplasty and evaluate for crystals before treating a presumed periprosthetic joint infection.
Calcific Tendonitis of the Shoulder: Protector or Predictor of Cuff Pathology? A Magnetic Resonance Imaging–Based Study
Purpose The purpose of this investigation is to assess the incidence of rotator cuff tears in cases of calcific tendonitis and evaluate for differences in the incidences of rotator cuff tears by magnetic resonance imaging (MRI) between calcific lesions of different morphology, size, or location. Methods This single‐center study involved a retrospective chart review searching for patients from January 2010 to April 2017 with a diagnosis of calcific tendonitis of the shoulder based on review of all MRI reads done on patients with shoulder pain. Anteroposterior radiographic and MRI studies were reviewed by a musculoskeletal radiologist to assess calcific tendonitis morphology, size, distance from cuff insertion, and any rotator cuff tear. An additional radiologist evaluated calcific tendonitis size, morphology, and location to evaluate the reliability of these variables. Results In the final cohort of 318 shoulders with calcific tendonitis, the incidence of concomitant rotator cuff tears was 56%. Of all 177 tears, 164 (93%) were partial‐thickness and 13 (7%) were complete. Type III calcification morphology (cloudy with soft contour) was most frequently associated with rotator cuff tears and demonstrated an increased odds of tear by a factor of 1.8 (CI 95% 1.1‐2.9).There was no statistical difference regarding calcification size or location prognosticating rotator cuff tears or tear thickness. Intraclass correlation coefficients for calcification size, morphology, and location were 0.78, 0.30, and 0.50, respectively. Conclusions The incidence of rotator cuff tears in cases of calcific tendonitis in this cohort of patients who underwent MRI is higher than previously reported. Cloudy‐appearing calcified lesions showed a significant association with rotator cuff tears with an odds ratio of 1.8. Specific locations or sizes of calcified lesions do not appear to be reliable factors to predict concomitant rotator cuff tears. Interobserver agreement for these radiographic variables ranged from fair to substantial and prompt a cautious interpretation of these results. Level of Evidence IV Retrospective Case Series.