ABSTRACT A 300-bp plasmid fragment of the hemagglutinin gene was used as target DNA to develop a rapid real-time LightCycler (Roche Applied Science, Indianapolis, Ind.) PCR assay for laboratory detection of smallpox virus. PCR primers and probes were designed specifically for detection of smallpox virus DNA, but all viruses of the genus Orthopoxvirus tested could be detected by use of the hemagglutinin gene target sequence. Base pair mismatches in the 204-bp amplicon allowed discrimination of cowpox virus (melting temperature [ T m ], 56.40°C), monkeypox virus ( T m , 56.24°C), and vaccinia virus ( T m , 56.72°C), including the Dryvax vaccine strain, from smallpox virus ( T m , 62.45°C) by melting curve analysis. The analytical sensitivity was 5 to 10 copies of target DNA per sample. The assay was specific for members of the genus Orthopoxvirus ; the DNAs of herpes simplex virus and varicella-zoster virus were not detected by the smallpox virus LightCycler PCR.
Comparative Quantitation of Cytomegalovirus (CMV) DNA in Solid Organ Transplant Recipients with CMV Infection by Using Two High-Throughput Automated Systems
Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4472-4476
ABSTRACT Cytomegalovirus (CMV) DNA quantitation in clinical specimens is progressively becoming a cornerstone in the diagnosis and management of CMV infection in the immunocompromised host. We evaluated two automated and reproducible PCR tests, the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.) and the COBAS AMPLICOR CMV Monitor (Roche Diagnostics, Pleasanton, Calif.), for the detection of CMV DNA in blood samples from transplant recipients with CMV infection as determined by shell vial culture. Following a log transformation analysis, the mean CMV DNA in plasma (PL), whole blood (WB), peripheral blood leukocytes (PBL), and peripheral blood mononuclear cells (PBMC) using the LightCycler was 6.79 copies per ml, 7.23 copies per ml, 6.38 copies per 2 × 10 6 cells, and 6.27 copies per 2 × 10 6 cells, respectively. This compares to 7.86 copies per ml, 8.37 copies per ml, 7.59 copies per 2 × 10 6 cells, and 7.44 copies per 2 × 10 6 cells, respectively, using COBAS AMPLICOR CMV Monitor. While higher CMV DNA levels were observed for the various blood compartments analyzed using COBAS AMPLICOR CMV Monitor, a high degree of correlation was evident between the two automated systems (jackknife correlation r = PL 0.77 [95% confidence interval (CI); 0.64, 0.90], WB 0.77 [95% CI; 0.62, 0.92], PBL 0.77 [95% CI; 0.67, 0.88], and PBMC 0.81 [95% CI; 0.72, 0.89], all P < 0.001). Therefore, we conclude that either automated diagnostic system is accurate for CMV DNA quantitation.
Detection of Herpes Simplex Virus DNA in Genital and Dermal Specimens by LightCycler PCR after Extraction using the IsoQuick, MagNA Pure, and BioRobot 9604 Methods
Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 6 | Pages: 2233-2236
ABSTRACT We evaluated two automated systems, MagNA Pure (Roche Molecular Biochemicals, Indianapolis, Ind.) and BioRobot 9604 (Qiagen, Inc., Chatsworth, Calif.) as effective replacements for the manual IsoQuick method (Orca Research, Inc., Bothell, Wash.) for extraction of herpes simplex virus (HSV) DNA from dermal and genital tract specimens prior to analysis by LightCycler PCR. Of 198 specimens (152 genital, 46 dermal), 92 (46.2%) were positive for HSV DNA by LightCycler PCR after automated extraction of specimens with either the MagNA Pure or BioRobot 9604 instrument. The manual IsoQuick method yielded HSV DNA (total n = 95) from three additional specimens that were negative by the automated method ( P = 0.25, sign test). Although the mean numbers of LightCycler PCR cycles required to reach positivity differed statistically significantly among all three of the methods of extraction, the estimated means differed by no more than 1.5 cycles ( P < 0.05). Seventy (76%) of the 92 specimens that were LightCycler PCR positive by all three extraction methods were also positive by shell vial cell culture assay. HSV DNA was detected by a lower LightCycler PCR cycle number (26.1 cycles) in specimens culture positive for the virus than in culture-negative samples (33.3 cycles) ( P < 0.0001). The manual IsoQuick and automated MagNA Pure and BioRobot 9604 methods provide standardized, reproducible extraction of HSV DNA for LightCycler PCR. The decision to implement a manual versus an automated procedure depends on factors such as costs related to the number of specimens processed rather than on the minimal differences in the technical efficiency of extraction of nucleic acids among these methods.
Role of the Laboratory in Diagnosis and Management of Cytomegalovirus Infection in Hematopoietic Stem Cell and Solid-Organ Transplant Recipients
Journal of Clinical Microbiology | July 27, 2002 | Volume: 40 | Issue: 3 | Pages: 746-752