Back to Authors

Anavekar, Nandan S.

A5017823480 | I1330342723

Mayo Clinic

Mayo Clinic

Citations 86

170: METASTATIC MYOCARDIAL CALCINOSIS FROM PEMBROLIZUMAB-INDUCED ACUTE RENAL AND RESPIRATORY FAILURE

Critical Care Medicine | December 18, 2018 | Volume: 47 | Issue: 1 | Pages: 67-67

10.1097/01.ccm.0000550925.34171.60

Aortic disease and interventions in adults with tetralogy of Fallot

Heart | December 4, 2018 | Volume: 105 | Issue: 12 | Pages: 926-931

10.1136/heartjnl-2018-314115 | PMID 30514730

Background Aortic dilation and aortic valve disease are known long-term complication of tetralogy of Fallot (TOF), but the risk of aortic dissection and the indications for prophylactic aortic surgery are unknown in this population. The purpose of this study was to: (1) determine the prevalence of significant aortic valve disease and/or significant aortic aneurysm (AVD-AA); (2) determine the incidence of progressive aortic dilation and aortic dissection in patients with TOF. Methods Retrospective review of adults with repaired TOF, and no prior aortic valve/aorta surgery, who had ≥2 measurements of the thoracic aorta >12 months apart, 1990–2017. The aortic root and mid-ascending aorta were measured at the onset of QRS complex from leading edge to leading edge. Significant aortic valve disease was defined as the presence of ≥moderate aortic stenosis and/or ≥moderate aortic regurgitation. Significant aortic aneurysm was defined as aortic root or mid-ascending aorta dimension ≥50 mm. Progressive aortic dilation was defined as increase in aortic dimension ≥2 mm. Results Of the 453 consecutive patients (37±13 years, men 216 (49%)) in the study, aortic aneurysm was present in 312 (69%) based on normative data; progressive aortic dilation occurred in 40 (9%), and there was no case of aortic dissection. Significant AVD-AA occurred in 52 (12%) patients; and 15 of them (29%) underwent aortic surgery without any surgical mortality. Conclusions Although aortic aneurysm was common, progressive aortic dilation was uncommon and aortic dissection did not occur in our patients with TOF with significant aortic aneurysms who did not undergo aortic surgery. This has important clinical implication in deciding the frequency of imaging follow-up and timing of surgical intervention in this population.
Imaging in blunt thoracic trauma: The importance of clinical correlation

Echocardiography | December 4, 2018 | Volume: 36 | Issue: 1 | Pages: 199-200

10.1111/echo.14219 | PMID 30511770

We present the case of a 26‐year‐old female restrained front‐seat passenger who presents following a motor vehicle accident, with CT angiogram features suggestive of possible acute aortic injury. However, clinical features including relative hemodynamic stability and absence of typical symptoms were discordant with these imaging findings. This case illustrates that even with ECG‐gating, CT angiogram artifact mimicking acute aortic injury may still occur. Careful evaluation and clinical correlation is of vital importance, both to ensure acute aortic injury is not missed and that patients are not erroneously sent for aortic surgery when there is no aortic injury. Careful clinical evaluation must be combined with imaging in all cases of suspected aortic trauma, and at times multimodality imaging is indicated to direct the decision making strategy.
Pre- and post-pericardiocentesis echo-Doppler features of effusive-constrictive pericarditis compared with cardiac tamponade and constrictive pericarditis

European Heart Journal - Cardiovascular Imaging | June 3, 2018 | Volume: 20 | Issue: 3 | Pages: 298-306

10.1093/ehjci/jey081 | PMID 29982372

Solving a Mystery . . . 8 Years Later

Journal of Investigative Medicine High Impact Case Reports | January 24, 2018 | Volume: 6 | Issue: No issue available | Pages: No page available

10.1177/2324709617752962 | PMID 29435464

Erdheim-Chester disease is a rare non-Langerhans cell histiocytosis with multisystem involvement and insidious symptoms. In this article, we describe an interesting case of Erdheim-Chester disease that was eventually diagnosed 8 years after symptoms initially started.
Three‐dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification

Catheterization and Cardiovascular Interventions | January 23, 2018 | Volume: 92 | Issue: 7 | Pages: No page available

10.1002/ccd.27488 | PMID 29359388

AbstractIntroductionThree‐dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR).MethodsEight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre‐procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result.Results3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post‐procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model.Conclusion3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.
Myocardial Cobalt Levels Are Elevated in the Setting of Total Hip Arthroplasty

Journal of Bone and Joint Surgery | November 15, 2017 | Volume: 99 | Issue: 22 | Pages: e118

10.2106/jbjs.17.00159 | PMID 29135673

Background: Arthroplasty implants commonly contain elemental metal that may undergo wear-related release. Recently, cases of hip implant-associated myocardial injury have been reported. However, we are not aware of any previous study that has systematically measured myocardial metal levels or examined the relationship with total hip arthroplasty (THA). Methods: Archives of our institution were queried for autopsies of individuals who had undergone THA between 1990 and 2013. Myocardial tissue samples were analyzed for cobalt (Co) and chromium (Cr) levels with inductively coupled plasma mass spectroscopy. Seventy-five Co/Cr-on-polyethylene THA cases were included (mean age at time of death = 77.4 years; 49% women) as were 73 non-arthroplasty controls matched for age, sex, and history of hypertension and diabetes mellitus. Results: Significantly higher median myocardial concentrations of Co were observed in individuals with THA compared with controls (0.12 versus 0.06 μg/g, p < 0.0001). The median Co concentration was 69% higher in patients who had undergone THA revision (0.169 μg/g) than in those who underwent primary THA (0.100 μg/g; p = 0.004). In general, higher Co levels were observed in those with multiple replaced joints, although this finding only trended toward significance. Cardiomegaly, interstitial fibrosis, and decreased ejection fraction were observed more frequently in the postmortem samples of patients with implants than in those of controls (p = 0.0002, 0.044, and 0.0039, respectively). Conclusions: We believe this to be the first study to quantify metal levels in cardiac tissue in patients with and without joint replacement. The elevated Co levels, in concert with cardiomegaly and increased interstitial fibrosis found during autopsy, in the arthroplasty cohort are novel, important findings. Although Co levels were significantly elevated above those in controls, the majority were below those seen in clinical case reports of death from Co cardiotoxicity associated with metal-on-metal prostheses. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Handheld echocardiography during hospitalization for acute myocardial infarction

Clinical Cardiology | July 19, 2017 | Volume: 40 | Issue: 11 | Pages: 993-999

10.1002/clc.22754 | PMID 28724192

BackgroundHandheld echocardiography (HHE) is concordant with standard transthoracic echocardiography (TTE) in a variety of settings but has not been thoroughly compared to traditional TTE in patients with acute myocardial infarction (AMI).HypothesisCompleted by experienced operators, HHE provides accurate diagnostic capabilities compared with standard TTE in AMI patients.MethodsThis study prospectively enrolled patients admitted to the coronary care unit with AMI. Experienced sonographers performed HHE with a V‐scan. All patients underwent clinical TTE. Each HHE was interpreted by 2 experts blinded to standard TTE. Agreement was assessed with κ statistics and concordance correlation coefficients.ResultsAnalysis included 82 patients (mean age, 66 years; 74% male). On standard TTE, mean left ventricular (LV) ejection fraction was 46%. Correlation coefficients between HHE and TTE were 0.75 (95% confidence interval: 0.66 to 0.82) for LV ejection fraction and 0.69 (95% confidence interval: 0.58 to 0.77) for wall motion score index. The κ statistics ranged from 0.47 to 0.56 for LV enlargement, 0.55 to 0.79 for mitral regurgitation, and 0.44 to 0.57 for inferior vena cava dilatation. The κ statistics were highest for the anterior (0.81) and septal (0.71) apex and lowest for the mid inferolateral (0.36) and basal inferoseptal (0.36) walls.ConclusionsIn patients with AMI, HHE and standard TTE demonstrate good correlation for LV function and wall motion. Agreement was less robust for structural abnormalities and specific wall segments. In experienced hands, HHE can provide a focused assessment of LV function in patients hospitalized with AMI; however, HHE should not substitute for comprehensive TTE.
Impact of New-Onset Left Ventricular Dysfunction on Outcomes in Mechanically Ventilated Patients With Severe Sepsis and Septic Shock

Journal of Intensive Care Medicine | January 15, 2017 | Volume: 33 | Issue: 12 | Pages: 680-686

10.1177/0885066616684774 | PMID 28553776

Background: Left ventricular systolic dysfunction (LVSD) and LV diastolic dysfunction (LVDD) are commonly seen in severe sepsis and septic shock; however, their role in patients with concurrent invasive mechanical ventilation (IMV) is less well defined. Methods: This was a prospective observational study on all patients admitted to all the intensive care units (ICUs) at Mayo Clinic, Rochester from August 2007 to January 2009. All adult patients with severe sepsis and septic shock and concurrent IMV without prior heart failure underwent transthoracic echocardiography within 24 hours. Patients with active pregnancy, prior congenital or valvular heart disease, and prosthetic cardiac valves were excluded. Left ventricular systolic dysfunction was defined as LV ejection fraction (LVEF) <50% and LVDD as E/e′ >15. Primary outcome was hospital mortality, and secondary outcomes included IMV duration, ICU length of stay (LOS), and total LOS. Two-tailed P value of <.05 was considered statistically significant. Results: In a total of 106 patients, 58 (54.7%) met our inclusion criteria, with 17 (29.3%), 11 (19.0%), and 5 (8.6%) having LVSD, LVDD, and both, respectively. The cohorts with and without LVSD and LVDD did not differ significantly in their baseline characteristics and laboratory and ventilatory parameters. Compared to those without LVSD, patients with LVSD had higher LV end-systolic diameters but were not different in their left atrial diameters or E/e′ ratio. Patients with LVDD had a higher E velocity and E/e′ ratio compared to those without LVDD. Hospital mortality was not different in patients with and without LVSD (8 [47%] vs 21 [51%], P = 1.00) and LVDD (8 [73%] vs 21 [45%], P = .18). Secondary outcomes were not different between the 2 groups. Conclusion: Left ventricular systolic or diastolic dysfunction did not influence in-hospital outcomes in patients with severe sepsis and septic shock and concurrent IMV.
Right Ventricle and Exercise Capacity

Circulation: Cardiovascular Imaging | November 14, 2016 | Volume: 9 | Issue: 11 | Pages: No page available

10.1161/circimaging.116.005703 | PMID 27903547