Citations 32

External Arrhythmia Ablation Using Photon Beams

Circulation: Arrhythmia and Electrophysiology | April 13, 2017 | Volume: 10 | Issue: 4 | Pages: No page available

10.1161/circep.116.004304 | PMID 28408649

Background— This study sought to investigate external photon beam radiation for catheter-free ablation of the atrioventricular junction in intact pigs. Methods and Results— Ten pigs were randomized to either sham irradiation or irradiation of the atrioventricular junction (55, 50, 40, and 25 Gy). Animals underwent baseline electrophysiological evaluation, cardiac gated multi-row computed tomographic imaging for beam delivery planning, and intensity-modulated radiation therapy. Doses to the coronary arteries were optimized. Invasive follow-up was conducted ≤4 months after the irradiation. A mean volume of 2.5±0.5 mL was irradiated with target dose. The mean follow-up length after irradiation was 124.8±30.8 days. Out of 7 irradiated animals, complete atrioventricular block was achieved in 6 animals of all 4 dose groups (86%). Using the same targeting margins, ablation lesion size notably increased with the delivered dose because of volumetric effects of isodose lines around the target volume. The mean macroscopically calculated atrial lesion volume for all 4 dose groups was 3.8±1.1 mL, lesions extended anteriorly into the interventricular septum. No short-term side effects were observed. No damage was observed in the tissues of the esophagus, phrenic nerves, or trachea. However, histology revealed in-field beam effects outside of the target volume. Conclusions— Single-fraction doses as low as 25 Gy caused a lesion with interruption of cardiac impulse propagation using this respective target volume. With doses of ≤55 Gy, maximal point-doses to coronary arteries could be kept <7Gy, but target conformity of lesions was not fully achieved using this approach.
Characterization of relative biological effectiveness for conventional radiation therapy: a comparison of clinical 6 MV X-rays and 137Cs

Journal of Radiation Research | April 5, 2017 | Volume: 58 | Issue: 5 | Pages: 608-613

10.1093/jrr/rrx018 | PMID 28444207

ABSTRACT Various types of radiation are utilized in the treatment of cancer. Equal physical doses of different radiation types do not always result in the same amount of biological damage. In order to account for these differences, a scaling factor known as the relative biological effectiveness (RBE) can be used. 137Cesium (137Cs) has been used as a source of radiation in a significant body of radiation therapy research. However, high-energy X-rays, such as 6 MV X-rays, are currently used clinically to treat patients. To date, there is a gap in the literature regarding the RBE comparison of these two types of radiation. Therefore, the purpose of this study was to investigate the RBE of 137Cs relative to that of 6 MV X-rays. To determine the RBE, five cell lines were irradiated [Chinese hamster ovary (CHO); human lung adenocarcinoma (A549); human glioma (U251); human glioma (T98); and human osteosarcoma (U2OS)] by both types of radiation and assessed for cell survival using a clonogenic assay. Three of the five cell lines resulted in RBE values of ~1.00 to within 11% for all survival fractions, showing the physical and biological dose for these two types of radiation were equivalent. The other two cell lines gave RBE values differing from 1.00 by up to 36%. In conclusion, the results show the range in biological effect seen between cell lines, and therefore cell type must be considered when characterizing RBE.
Treatment planning for metals using an extended CT number scale

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 6 | Pages: 179-188

10.1120/jacmp.v17i6.6153 | PMID 27929492

Metal implants which saturate the CT number scale may require dosimetrist and physicist involvement to manually contour and assign an appropriate value to the metal for accurate dose calculation. This study investigated dose calculation based directly on extended CT scale images for different metals and geometries. The aim was to evaluate extended CT accuracy as a suitable alternative to standard CT methods in the presence of high‐Z materials and artifacts, despite the reduced HU resolution of extended CT. Gafchromic film measurements were made for comparison to calculated doses. The method of direct dose calculation on extended CT scale was compared to our institution's standard method of manually contouring and assigning metal values on saturated CT images for each of the metal samples. Clinical patient plans with metal implants were investigated and DVHs were compared between standard CT and extended CT dose calculations. Dose calculations showed agreement within 2% between the two methods of metal characterization and the film measurement in the case of the strongest metal attenuator, cobalt‐chromium. In the clinical treatment plans, the greatest dose discrepancy between the two methods was 1.2%. This study suggests that direct dose calculation on an extended scale CT image in the presence of metal implants can produce accurate clinically viable treatment plans, thereby improving efficiency of clinical workflow and eliminating a potential source of human error by manual CT number assignment.PACS number(s): 87.55.dk
Systematic offset of kV and MV localization systems as a function of gantry angle

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 12 | Issue: 1 | Pages: 122-128

10.1120/jacmp.v12i1.3314 | PMID 21330978

Mechanical flex of the gantry and mounted imaging panels leads to systematic offsets in localization image isocenter as a function of gantry angle for linear accelerator‐mounted image guidance systems. Subsequently, object positions obtained from localization radiographs may be offset, resulting in greater target positioning uncertainty. While current QA procedures measure kV/MV image agreement, these measurements do not provide insight to apparent isocenter position for either single imaging system as a function of gantry rotation. This study measures offset as a function of gantry angle in kV and MV imaging systems on four treatment machines to investigate the magnitude of systematic offsets and their reproducibility between systems and machines, as well as over time. It is shown that each machine and energy has a reproducible pattern of offset as a function of gantry angle that is independent of kV/MV agreement, and it varies by machine. kV and MV offset ranges are on the order of 1.5 mm in the R/L and A/P directions, and 0.5 mm in the S/I direction. Variability of kV‐MV agreement is on the order of 0.7 mm. At certain angles, combinations of localization images could show a compounded offset of over 2 mm, exceeding the desired certainty threshold. Since these trends are persistent over time for each machine, online correction for image offsets as a function of gantry angle could improve the margin of positioning uncertainty.PACS number: 87.55.Qr
Guest Editorial: Patient safety and errors in the application of medical radiation: our responsibility

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 11 | Issue: 2 | Pages: 2-4

10.1120/jacmp.v11i2.3329 | PMID 20592707

Atrioventricular Node Ablation in Langendorff-Perfused Porcine Hearts Using Carbon Ion Particle Therapy

Circulation: Arrhythmia and Electrophysiology | January 22, 2015 | Volume: 8 | Issue: 2 | Pages: 429-438

10.1161/circep.114.002436 | PMID 25609687

Background— Particle therapy, with heavy ions such as carbon-12 ( 12 C), delivered to arrhythmogenic locations of the heart could be a promising new means for catheter-free ablation. As a first investigation, we tested the feasibility of in vivo atrioventricular node ablation, in Langendorff-perfused porcine hearts, using a scanned 12C beam. Methods and Results— Intact hearts were explanted from 4 (30–40 kg) pigs and were perfused in a Langendorff organ bath. Computed tomgraphic scans (1 mm voxel and slice spacing) were acquired and 12 C ion beam treatment planning (optimal accelerator energies, beam positions, and particle numbers) for atrioventricular node ablation was conducted. Orthogonal x-rays with matching of 4 implanted clips were used for positioning. Ten Gray treatment plans were repeatedly administered, using pencil beam scanning. After delivery, positron emission tomography-computed tomgraphic scans for detection of β + ( 11 C) activity were obtained. A 12 C beam with a full width at half maximum of 10 mm was delivered to the atrioventricular node. Delivery of 130 Gy caused disturbance of atrioventricular conduction with transition into complete heart block after 160 Gy. Positron emission computed tomgraphy demonstrated dose delivery into the intended area. Application did not induce arrhythmias. Macroscopic inspection did not reveal damage to myocardium. Immunostaining revealed strong γH2AX signals in the target region, whereas no γH2AX signals were detected in the unirradiated control heart. Conclusions— This is the first report of the application of a 12 C beam for ablation of cardiac tissue to treat arrhythmias. Catheter-free ablation using 12C beams is feasible and merits exploration in intact animal studies as an energy source for arrhythmia elimination.
Book Review

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 7 | Issue: 2 | Pages: 101-102

10.1120/jacmp.v7i2.2239

The Modern Technology of Radiation Oncology, Vol. 2, edited by Jacob Van Dyk, Medical Physics Publishing, 2005, ISBN‐10:1‐930524‐25‐0 (hard cover), list price $120 hard cover, $100 soft cover
Patient‐specific daily pretreatment setup protocol using electronic portal imaging for radiation therapy

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 6 | Issue: 4 | Pages: 1-13

10.1120/jacmp.v6i4.1954 | PMID 16421496

The purpose of this study was to evaluate electronic portal imaging (EPI) as a means of identifying and correcting field displacement in patients with problematic external beam radiotherapy setups. Fourteen patients with problematic setups were identified for pretreatment daily EPI beam monitoring as part of a physician‐directed therapist intervention protocol. Pretreatment EPIs were used to realign fields as necessary to bring the setup within the physician‐prescribed tolerance level. For comparison, daily EPIs were available for 12 control patients who had no particular setup difficulties and for whom online beam realignment was not made. Anatomy‐matching software was used to measure setup variation along medial‐lateral, superior‐inferior, and anterior‐posterior axes. Online field realignment yielded a significant improvement when comparing initial and final setup variations. The mean standard deviation of setup displacement averaged over three axes was reduced from 6.4 mm to 3.1 mm after realignment. The final variation of protocol patients was comparable to that of control patients. In conclusion, EPI provided effective means to perform online beam realignment in a group of difficult‐to‐position patients. This procedure resulted in a reduction in setup displacement that was statistically significant, clinically relevant, and approached that of a more typical patient group.PACS number: 87.53.Oq
A buccal mucosa carcinoma treated with high dose rate brachytherapy

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 6 | Issue: 1 | Pages: 8-12

10.1120/jacmp.v6i1.2064 | PMID 15770193

This manuscript presents a case of early stage squamous cell carcinoma of the left buccal mucosa treated with intensity‐modulated radiation therapy (IMRT) followed by a high‐dose rate (HDR) brachytherapy boost. With limited literature available on HDR mold (stent) radiotherapy for oral cancer, a discussion on the issues encountered during treatment planning and delivery may prove to be insightful for facilities faced with a similar challenge.PACS numbers: 87.53.Jw, 87.53.Tf, 87.59.Ci, 87.59.Fm
Utilizing an electronic portal imaging device to monitor light and radiation field congruence

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 4 | Issue: 4 | Pages: 315-320

10.1120/jacmp.v4i4.2502 | PMID 14604421

A method to investigate light and radiation field congruence utilizing a commercially available amorphous silicon electronic portal imaging device (EPID) was developed. This method employed an EPID, the associated EPI software, and a diamond‐shaped template. The template was constructed from a block tray in which Sn/Pb wires, 1 mm in diameter, were embedded into a diamond shaped groove milled into the tray. The collimator jaws of the linac were aligned such that the light field fell directly on the corners of the diamond. A radiation detection algorithm within the EPI software determined the extent of the radiation field. The light and radiation field congruence was evaluated by comparing the vertexes of the diamond reference structure to the detected radiation field. In addition, the digital jaw settings were recorded and later compared to the light field detected on the films and EPIs. Three linear accelerators were tracked for a period ranging from 2–8 months. Light radiation field congruence tests with films and EPIs were comparable, yielding a difference of less than 0.6 mm, well within the allowed 2‐mm tolerance. A disparity was observed in the magnitude of the detected light field. The X and Y dimensions of the light field measured with film differed by less than or equal to 1.4 mm from the digital collimator settings, whereas the values extracted from the EPIs differed by up to 2.5 mm. Based on these findings, EPIs were found to be a quick and reliable alternative to film for qualitative and relative analyses.PACS number(s): 87.53.Xd, 87.56.Fc, 87.53.Oq, 87.52.–g, 87.53.–j