Citations 89

Quantitative Computed Tomography Protocols Affect Material Mapping and Quantitative Computed Tomography-Based Finite-Element Analysis Predicted Stiffness

Journal of Biomechanical Engineering | July 18, 2016 | Volume: 138 | Issue: 9 | Pages: No page available

10.1115/1.4034172 | PMID 27428281

Quantitative computed tomography-based finite-element analysis (QCT/FEA) has become increasingly popular in an attempt to understand and possibly reduce vertebral fracture risk. It is known that scanning acquisition settings affect Hounsfield units (HU) of the CT voxels. Material properties assignments in QCT/FEA, relating HU to Young's modulus, are performed by applying empirical equations. The purpose of this study was to evaluate the effect of QCT scanning protocols on predicted stiffness values from finite-element models. One fresh frozen cadaveric torso and a QCT calibration phantom were scanned six times varying voltage and current and reconstructed to obtain a total of 12 sets of images. Five vertebrae from the torso were experimentally tested to obtain stiffness values. QCT/FEA models of the five vertebrae were developed for the 12 image data resulting in a total of 60 models. Predicted stiffness was compared to the experimental values. The highest percent difference in stiffness was approximately 480% (80 kVp, 110 mAs, U70), while the lowest outcome was ∼1% (80 kVp, 110 mAs, U30). There was a clear distinction between reconstruction kernels in predicted outcomes, whereas voltage did not present a clear influence on results. The potential of QCT/FEA as an improvement to conventional fracture risk prediction tools is well established. However, it is important to establish research protocols that can lead to results that can be translated to the clinical setting.
Comparison of Passive Stiffness Changes in the Supraspinatus Muscle After Double‐Row and Knotless Transosseous‐Equivalent Rotator Cuff Repair Techniques: A Cadaveric Study

Arthroscopy | May 4, 2016 | Volume: 32 | Issue: 10 | Pages: 1973-1981

10.1016/j.arthro.2016.02.024 | PMID 27157656

Purpose To investigate the alteration of passive stiffness in the supraspinatus muscle after double‐row (DR) and knotless transosseous‐equivalent (KL‐TOE) repair techniques, using shear wave elastography (SWE) in cadavers with rotator cuff tears. We also aimed to compare altered muscular stiffness after these repairs to that obtained from shoulders with intact rotator cuff tendon. Methods Twelve fresh‐frozen cadaveric shoulders with rotator cuff tear (tear size: small [6], medium‐large [6]) were used. Passive stiffness of 4 anatomic regions in the supraspinatus muscle was measured based on an established SWE method. Each specimen underwent DR and KL‐TOE footprint repairs at 30° glenohumeral abduction. SWE values, obtained at 0°, 10°, 20°, 30°, 60°, and 90° abduction, were assessed in 3 different conditions: preoperative (torn) and postoperative conditions with the 2 techniques. The increased ratio of SWE values after repair was compared among the 4 regions to assess stiffness distribution. In addition, SWE values were obtained on 12 shoulders with intact rotator cuff tendons as control. Results In shoulders with medium‐large‐sized tears, supraspinatus muscles showed an increased passive stiffness after rotator cuff repairs, and this was significantly observed at adducted positions. KL‐TOE repair showed uniform stiffness changes among the 4 regions of the supraspinatus muscle (mean, 189% to 218% increase after repair), whereas DR repair caused a significantly heterogeneous stiffness distribution within the muscle (mean, 187% to 319% after repair, P = .002). Although a repair‐induced increase in muscle stiffness was observed also in small‐sized tears, there were no significant differences in repaired stiffness changes between DR and KL‐TOE (mean, 127% to 138% and 127% to 130% after repairs, respectively). Shoulders with intact rotator cuff tendon showed uniform SWE values among the 4 regions of the supraspinatus muscle (mean, 38.2 to 43.0 kPa). Conclusions Passive stiffness of the supraspinatus muscle increases after rotator cuff repairs for medium‐large‐sized tears. KL‐TOE technique for the medium‐large‐sized tear provided a more uniform stiffness distribution across the repaired supraspinatus muscles compared with the DR technique. Clinical Relevance Based on this insight, investigating rotator cuff muscle stiffness changes, further studies using SWE may determine the optimal repair technique for various sizes of rotator cuff tears.
THE EFFECT OF FREEZING ON BIOMECHANICAL PROPERTIES OF THE CARPAL TUNNEL SUBSYNOVIAL CONNECTIVE TISSUE

Journal of Musculoskeletal Research | April 7, 2016 | Volume: 18 | Issue: 04 | Pages: 1550019

10.1142/s0218957715500190

Biomechanical evaluation of the subsynovial connective tissue (SSCT) provides insight into the causes of carpal tunnel syndrome. Studies of carpal tunnel mechanics have been performed using fresh-frozen cadaver tissue. Freezing can affect mechanical properties of some tissues, but its effect on SSCT is unknown. A total of 16 rabbit paws were harvested from eight New Zealand rabbits and subjected to mechanical testing consisting of three repeated tendon excursions in sets of three different excursion magnitudes. One paw from each animal was unfrozen. The contralateral paw was frozen and thawed before testing. Force, energy and stiffness of the first cycle of each set were evaluated, as were ratios of the second to first cycle for each parameter. Two-factor ANOVA with repeated measures over both factors was performed. No significant interactions between factors were found. There were no significant differences between fresh and frozen paws for any parameters, though there were significant differences between excursion amplitudes. The damage threshold was not different between fresh and frozen paws. This study demonstrated that freezing rabbit subsynovial connective tissue does not significantly change its mechanical properties. The same may be true for human cadaver tissues. Results of cadaver mechanical testing may not be influenced by this preservation technique.
Effects of lubricant and autologous bone marrow stromal cell augmentation on immobilized flexor tendon repairs

Journal of Orthopaedic Research | July 16, 2015 | Volume: 34 | Issue: 1 | Pages: 154-160

10.1002/jor.22980 | PMID 26177854

ABSTRACTThe purpose of the study was to test a novel treatment that carbodiimide‐derivatized‐hyaluronic acid‐lubricin (cd‐HA‐lubricin) combined cell‐based therapy in an immobilized flexor tendon repair in a canine model. Seventy‐eight flexor tendons from 39 dogs were transected. One tendon was treated with cd‐HA‐lubricin plus an interpositional graft of 8 × 105 BMSCs and GDF‐5. The other tendon was repaired without treatment. After 21 day of immobilization, 19 dogs were sacrificed; the remaining 20 dogs underwent a 21‐day rehabilitation protocol before euthanasia. The work of flexion, tendon gliding resistance, and adhesion score in treated tendons were significantly less than the untreated tendons (p < 0.05). The failure strength of the untreated tendons was higher than the treated tendons at 21 and 42 days (p < 0.05). However, there is no significant difference in stiffness between two groups at day 42. Histologic analysis of treated tendons showed a smooth surface and viable transplanted cells 42 days after the repair, whereas untreated tendons showed severe adhesion formation around the repair site. The combination of lubricant and cell treatment resulted in significantly improved digit function, reduced adhesion formation. This novel treatment can address the unmet needs of patients who are unable to commence an early mobilization protocol after flexor tendon repair. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:154–160, 2016.
Lubricin in human achilles tendon: The evidence of intratendinous sliding motion and shear force in achilles tendon

Journal of Orthopaedic Research | April 11, 2015 | Volume: 33 | Issue: 6 | Pages: 932-937

10.1002/jor.22897 | PMID 25864860

ABSTRACTAchilles tendon is one of the most commonly injured tendons. Mechanical force is regarded as a major causative factor. However, the biomechanics of Achilles tendon and mechanical mechanism of the injuries are unclear. Lubricin expresses at regions exposed to sliding motion and shear force in a number of tissues. This study investigated the distribution and concentration of lubricin in human Achilles tendons for better understanding the biomechanics of Achilles tendon. Achilles tendons were harvested from nine cadavers. Lubricin was extracted from various locations proximal to the calcaneal insertion and quantified with ELISA. The distribution of lubricin was investigated with immunohistochemistry. Lubricin was mainly identified at the interfaces of tendon fascicles, especially in the mid‐portion of the tendon. The concentration of lubricin in Achilles tendons varied by individual and the distance from its calcaneal insertion. The distal portion of the tendon had a higher concentration of lubricin than the proximal regions of the tendon. This study suggests the presence of intratendinous sliding motion of fascicles and shear force at interfaces of fascicles in human Achilles tendon. Shear force could be an important mechanical factor for the development of Achilles tendinopathy and rupture. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:932–937, 2015.
Biomechanical evaluation of flexor tendon graft with different repair techniques and graft surface modification

Journal of Orthopaedic Research | February 9, 2015 | Volume: 33 | Issue: 5 | Pages: 731-737

10.1002/jor.22844 | PMID 25665071

ABSTRACTThe purpose of this study was to investigate the biomechanical properties of modified repair techniques for flexor tendon reconstruction and the effects of surface modification using carbodiimide‐derivatized synovial fluid plus gelatin (cd‐SF‐G), compared to the traditional repair techniques. The second and fifth digits from 16 canine forepaws were randomly divided into 4 groups: (1) traditional graft repairs (TGR group) including distal Bunnell repair and proximal Pulvertaft weave repair; (2) modified graft repairs (MGR group) including distal graft bony attachment repair and proximal step‐cut repair; (3) group TGR coated with cd‐SF‐G (TGR‐C group); and (4) group MGR coated with cd‐SF‐G (MGR‐C group). Digit normalized work of flexion (nWOF), ultimate failure strength, and stiffness were measured. The nWOF in MGR group was significantly less than TGR group (p < 0.05). The nWOF in groups treated with cd‐SF‐G was significantly less than their untreated counterparts (p < 0.05). Ultimate load to failure of the MGR‐C group was significantly greater than the TGR‐C group (p < 0.05), but no significant difference in stiffness was found between these two groups. The modified techniques cannot only improve tendon gliding abilities but can also improve breaking strength. Additionally, surface modification with cd‐SF‐G significantly decreased the work of flexion. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:731–737, 2015.
The effect of tendon excursion velocity on longitudinal median nerve displacement: Differences between carpal tunnel syndrome patients and controls

Journal of Orthopaedic Research | January 29, 2015 | Volume: 33 | Issue: 4 | Pages: 483-487

10.1002/jor.22804 | PMID 25640903

ABSTRACTThe subsynovial connective tissue (SSCT) is a viscoelastic structure connecting the median nerve (MN) and the flexor tendons in the carpal tunnel. Increased strain rates increases stiffness in viscoelastic tissues, and thereby its capacity to transfer shear load. Therefore, tendon excursion velocity may impact the MN displacement. In carpal tunnel syndrome (CTS) the SSCT is fibrotic and may be ruptured, and this may affect MN motion. In this study, ultrasonography was performed on 14 wrists of healthy controls and 25 wrists of CTS patients during controlled finger motions performed at three different velocities. Longitudinal MN and tendon excursion were assessed using a custom speckle tracking algorithm and compared across the three different velocities. CTS patients exhibited significantly less MN motion than controls (p ≤ 0.002). While in general, MN displacement increased with increasing tendon excursion velocity (p ≤ 0.031). These findings are consistent with current knowledge of SSCT mechanics in CTS, in which in some patients the fibrotic SSCT appears to have ruptured from the tendon surface. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:483–487, 2015.
Collagen gel contraction as a measure of fibroblast function in an animal model of subsynovial connective tissue fibrosis

Journal of Orthopaedic Research | January 28, 2015 | Volume: 33 | Issue: 5 | Pages: 668-674

10.1002/jor.22835 | PMID 25626430

ABSTRACTCarpal tunnel syndrome (CTS) is a peripheral neuropathy characterized by non‐inflammatory fibrosis of the subsynovial connective tissues (SSCT). A rabbit model of CTS was developed to test the hypothesis that SSCT fibrosis causes the neuropathy. We used a cell‐seeded collagen‐gel contraction model to characterize the fibrosis in this model in terms of cellular mechanics, specifically to compare the ability of SSCT cells from the rabbit model and normal rabbits to contract the gel, and to assess the effect of transforming growth factor‐β1,which is upregulated in CTS, on these cells. SSCT fibrosis was induced in six retired breeder female rabbits which were sacrificed at 6 weeks (N = 3) and 12 weeks (n = 3). An additional two rabbits served as controls. SSCT was harvested according to a standard protocol. Gels seeded with SSCT cells from rabbits sacrificed at 6 weeks had significantly higher tensile strength (p < 0.001) and Young's modulus (p < 0.001) than gels seeded with cells from rabbits sacrificed at 12 weeks or control animals. TGF‐β1 significantly increased the decay time constant (p < 0.001), tensile strength (p < 0.001), and Young's modulus (p < 0.001) regardless of the cell source. This model may be useful in screening therapeutic agents that may block SSCT fibrosis, identifying possible candidates for CTS treatment. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:668–674, 2015.
Effects of trypsinization and mineralization on intrasynovial tendon allograft healing to bone

Journal of Orthopaedic Research | January 21, 2015 | Volume: 33 | Issue: 4 | Pages: 468-474

10.1002/jor.22779 | PMID 25611186

ABSTRACTThe purpose of the current study was to develop a novel technology to enhance tendon‐to‐bone interface healing by trypsinizing and mineralizing (TM) an intrasynovial tendon allograft in a rabbit bone tunnel model. Eight rabbit flexor digitorum profundus (FDP) tendons were used to optimize the trypsinization process. An additional 24 FDP tendons were stratified into control and TM groups; in each group, 4 tendons were used for in vitro evaluation of TM and 8 were transplanted into proximal tibial bone tunnels in rabbits. The samples were evaluated histologically and with mechanical testing at postoperative week 8. Maximum failure strength and linear stiffness were not significantly different between the control and TM tendons. A thin fibrous band of scar tissue formed at the graft‐to‐bone interface in the control group. However, only the TM group showed obvious new bone formation inside the tendon graft and a visible fibrocartilage layer at the bone tunnel entrance. This study is the first to explore effects of TM on the intrasynovial allograft healing to a bone tunnel. TM showed beneficial effects on chondrogenesis, osteogenesis, and integration of the intrasynovial tendon graft, but mechanical strength was the same as the control tendons in this short‐term in vivo study. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:468–474, 2015.
Carpal Tunnel Syndrome Pathophysiology: Role of Subsynovial Connective Tissue

Journal of Wrist Surgery | October 24, 2014 | Volume: 03 | Issue: 04 | Pages: 220-226

10.1055/s-0034-1394133 | PMID 25364632