Background and Purpose— We report a preclinical study of a new endoluminal device for aneurysm occlusion to test the hypothesis that the device, even without use of intrasaccular coil placement, could occlude saccular aneurysms without causing substantial parent artery compromise or compromise of adjacent, small branch arteries. Methods— The Pipeline Neuroendovascular Device (Pipeline NED; Chestnut Medical Technologies, Inc) is a braided, tubular, bimetallic endoluminal implant aimed at occlusion of saccular aneurysms through flow disruption along the aneurysm neck. The device was implanted across the necks of 17 elastase-induced aneurysms in the New Zealand white rabbit model and followed for 1 month (n=6), 3 months (n=5), and 6 months (n=6). In each subject, a second device was implanted in the abdominal aorta to cover the origins of lumbar arteries. Aneurysm occlusion rates by angiography (grade 1, complete occlusion; grade 2, near-complete occlusion; and grade 3, incomplete occlusion) were documented. Percent area stenosis of the parent arteries was calculated. Presence of distal emboli in the downstream vessels in the parent artery and branch artery stenosis or occlusion was noted. Results— Grades 1, 2, and 3 occlusion rates were noted in 9 (53%), 6 (35%), and 2 (12%) of 17 aneurysms, respectively, indicating an 88% rate of complete or near complete occlusion. No cases of branch artery occlusion or distal emboli in the downstream vessels of the parent artery, specifically the subclavian artery, were seen. Parent artery compromise from neointimal hyperplasia was minimal in most cases. Conclusions— The Pipeline NED is a trackable, bio- and hemocompatible device able to occlude saccular aneurysms with preservation of the parent artery and small, adjacent branch vessels.
Endovascular Treatment of Experimental Aneurysms by Use of Fibroblast-Coated Platinum Coils
Background and Purpose— The purpose of this study was to determine whether implanting exogenous fibroblasts on platinum coils could enhance intra-aneurysmal fibrosis. Hypotheses included: (1) fibroblast-coated (FBC) platinum coils can improve angiographic results after embolization; and (2) FBC platinum coils can accelerate histological healing of embolized aneurysms. Methods— Experimental aneurysms in rabbits were embolized with control platinum coils (n=18) or FBC coils (n=18). Subjects were euthanized at 14 days, 1 month, 3 months and 6 months after implantation. Digital subtraction angiography was used to evaluate stability after embolization. Histological samples were examined with a grading system (range, 0 to 12) based on neck and dome healing. Results— Histology total scores and fibrosis ratio at 14 days were significantly greater in the FBC coil group compared with controls (6.6±1.9 versus 2.5±1.1, 1.2±0.6% versus 0.2±0.3%, respectively; P =0.0090). Cavities embolized with FBC coils showed cellular proliferation and thrombus organization, with an endothelialized membrane bridging the neck. There were no differences between groups in the later timepoints. The FBC coil group showed radiographic stability in 11 (61%) cases, coil compaction in 2 (11%) cases, and progressive occlusion in 5 (28%) cases. No progressive occlusion was seen in controls; 3 (17%) of 18 control cases exhibited coil compaction ( P =0.0546). Conclusions— FBC coils can accelerate early histological healing compared with control coils in the rabbit aneurysm model.