Citations 54

Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study

Interventional Neuroradiology | February 27, 2017 | Volume: 23 | Issue: 3 | Pages: 279-284

10.1177/1591019917694479 | PMID 28604189

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.
Autologous adipose-derived mesenchymal stem cells improve healing of coiled experimental saccular aneurysms: an angiographic and histopathological study

Journal of NeuroInterventional Surgery | January 11, 2017 | Volume: 10 | Issue: 1 | Pages: 60-65

10.1136/neurintsurg-2016-012867 | PMID 28077523

Purpose Long-term occlusion of coiled aneurysms frequently fails, probably because of poor intrasaccular healing and inadequate endothelialization across the aneurysm neck. The purpose of this study was to determine if attachment of autologous mesenchymal stem cells (MSCs) to platinum coils would improve the healing response in an elastase-induced aneurysm model in rabbits. Materials and methods With approval from the institutional animal care and use committee, aneurysms were created in rabbits and embolized with control platinum coils (Axium; Medtronic) (n=6) or coils seeded ex vivo with autologous adipose-tissue MSCs (n=7). Aneurysmal occlusion after embolization was evaluated at 1 month with angiography. Histological samples were analyzed by gross imaging and graded on the basis of neck and dome healing on H&E staining. Fibrosis was evaluated using a ratio of the total area presenting collagen. Endothelialization of the neck was quantitatively analyzed using CD31 immunohistochemistry. χ2 and Student's t-test were used to compare groups. Results Healing score (11.5 vs 8.0, p=0.019), fibrosis ratio (10.3 vs 0.13, p=0.006) and endothelialization (902 262 μm2 vs 31 810 μm2, p=0.041) were significantly greater in the MSC group. The MSC group showed marked cellular proliferation and thrombus organization, with a continuous membrane bridging the neck of the aneurysm. Angiographic stable or progressive occlusion rate was significantly lower in the MSC group (0.00, 95% CI 0.00 to 0.41) compared with controls (0.67, 95% CI 0.22 to 0.96) (p=0.02). Conclusions Autologous MSCs attached to platinum coils significantly improve histological healing, as they result in improved neck endothelialization and collagen matrix formation within the aneurysm sac.
Concomitant aneurysm detection in an intracranial dolichoectasia mouse model using a MicroFil polymer perfusion technique

Journal of NeuroInterventional Surgery | July 5, 2016 | Volume: 9 | Issue: 8 | Pages: 783-786

10.1136/neurintsurg-2016-012469 | PMID 27382123

Objective To assess the feasibility of using MicroFil polymer perfusion to detect concomitant saccular aneurysms in an intracranial arterial dolichoectasia (IADE) model in mice, and to report detailed histomorphometric features of these aneurysms. Materials and methods IADE models were created in C57/BL6 mice via microsurgical injection of 25 mU elastase into the cisterna magna. The cerebral vasculature was perfused with MicroFil polymer and harvested at 1, 3, and 7 days, and 2 and 4 weeks (n=8 for each group). IADE was defined by a tortuosity index >10 combined with a 25% increase in diameter of the A1 segment of the anterior cerebral artery (ACA), internal carotid artery (ICA), or basilar artery compared with the baseline of controls, which received heat-inactivated elastase. Saccular aneurysm occurrence rate, location, and morphological parameters were investigated using macroscopic and microscopic analysis. Results IADE was present in 95% (36/38) of the subjects, with a mortality rate of 5% (2/40). Fifteen concomitant saccular aneurysms were detected in 8 (21%) of the 38 surviving mice, including 6 at the posterior communicating artery, 1 along the ACA, 2 along the anterior communicating artery complex, 3 along the ICA, and 3 along the middle cerebral artery. Rupture was confirmed in two aneurysms. Histological examination indicated that the aneurysms develop via arterial-wall remodelling, which is characterized by internal elastic lamina disruptions and muscular layer discontinuity in the media. Conclusions The proportion of subjects developing saccular aneurysms in addition to IADE in our mouse model is similar to the 15% of patients with IADE who have concomitant saccular aneurysms.
O-023 experimental testing of new generation of woven endobridge devices in elastase-induced aneurysms in rabbits

Oral abstracts | June 8, 2016 | Volume: No volume available | Issue: No issue available | Pages: A12-A12

10.1136/neurintsurg-2015-011917.23

Experimental testing of the dual-layer Woven EndoBridge device using an elastase-induced aneurysm model in rabbits

Interventional Neuroradiology | February 4, 2016 | Volume: 22 | Issue: 3 | Pages: 299-303

10.1177/1591019916628202 | PMID 26847799

The dual-layer Woven EndoBridge (WEB) device (WEB II) is designed to improve the performance of the first-generation WEB device. This study was performed to evaluate the acute and chronic performance of WEB II for aneurysm occlusion in an elastase-induced aneurysm model in rabbits. We implanted WEB II devices in 36 elastase-induced aneurysms and followed up for one, three, six, and 12 months. Degree of aneurysm occlusion at follow-up was graded on the Web Occlusion Scale (WOS): Grade A, complete aneurysm occlusion; Grade B, complete occlusion with recess filling; Grade C, residual neck filling; and Grade D, residual aneurysm filling. Hematoxylin and eosin staining was performed for histological assessment of aneurysm healing. Grades A, B, C, and D aneurysm occlusion at one-month follow-up were noted in three (17%), three (17%), eight (44%), and four (22%) of 18 cases, respectively. At the three-month time point Grades A, B, C, and D were shown in two (33%), two (33%), one (17%), and one (17%) aneurysms. Six months after treatment, one (17%), two (33%), two (33%), and one (17%) cases demonstrated Grades A, B, C, and D occlusion. At the 12-month time point, Grades B, C, and D were shown in three (50%), two (33%), and one (17%) aneurysms. Histologic evaluation showed progressive thrombus organization within aneurysm lumen from one to 12 months. These results indicated that the WEB II device can achieve high rates of aneurysm occlusion over time in experimental aneurysms.
Histopathological findings following pipeline embolization in a human cerebral aneurysm at the basilar tip

Interventional Neuroradiology | February 3, 2016 | Volume: 22 | Issue: 2 | Pages: 153-157

10.1177/1591019915622165 | PMID 26842611

We report histopathological findings from a human cerebral aneurysm following treatment with a flow diverter. A 75-year-old male underwent flow diversion treatment (Pipeline Embolization Device (PED)) and coil embolization for treatment of an aneurysm at the basilar tip. At four months, angiography showed complete aneurysm occlusion; at 12 months angiography demonstrated that the aneurysm had reopened. The patient expired from brainstem compression. The aneurysm cavity was primarily filled with unorganized thrombus. Thick, interrupted neointima crossed the neck interface indicating blood flow into aneurysm through small channels. Along the parent artery the PED was covered by neointima having a measured thickness of 0.19 ± 0.01 mm; the maximal stenosis of the proximal parent artery was 27%. The perforating arteries that were crossed by the PED remained patent. Findings in this human case are similar to those in the elastase-induced aneurysms in rabbits.
Characterizing patterns of endothelialization following coil embolization: a whole-mount, dual immunostaining approach

Journal of NeuroInterventional Surgery | February 2, 2015 | Volume: 8 | Issue: 4 | Pages: 402-406

10.1136/neurintsurg-2014-011513 | PMID 25646129

Background The extent, rate, and source of endothelialization following coil embolization of saccular aneurysms remains poorly understood. We performed a whole tissue mount, dual immunohistochemical analysis of experimental aneurysms to characterize the state of endothelialization over time after platinum coil embolization. Method and material Elastase-induced rabbit aneurysms were created and treated with bare platinum coils. Samples were harvested at 4 and 8 weeks (n=6 for each). En face whole tissue mount staining with antibodies to CD31 and α-smooth muscle actin was used to identify endothelial cells and smooth muscle cells, respectively. Sytox green stain was used to demonstrate nuclear morphology for identification of inflammatory cells. The extent of endothelialization was measured in relation to the aneurysm neck–parent artery interface. Results At 4 weeks after coil embolization, very localized membranous tissue and neoendothelial cells were detected on the coil loops immediately adjacent to the parent artery–neck interface, but the remainder of the coil loops remained devoid of endothelial cells. At 8 weeks neoendothelial cells were more confluent over the coils than at 4 weeks, and extended up to 900 µm from the parent artery–neck interface. However, the surfaces of the coils farther away than this region harbored no endothelial cells. Scattered inflammatory cells, including neutrophils and monocytes, were seen on the coil surface at the neck central area, where the coil surface was bare at the 4 and 8 weeks’ follow-up. Conclusions Platinum coil embolization supports gradual but limited endothelialization, where endothelial cells migrate directly from the adjacent parent artery.
Gene expression comparison of flow diversion and coiling in an experimental aneurysm model

Journal of NeuroInterventional Surgery | October 20, 2014 | Volume: 7 | Issue: 12 | Pages: 926-930

10.1136/neurintsurg-2014-011452 | PMID 25332413

Background and purpose Mechanisms of both healing and complications, including spontaneous aneurysm rupture, remain unclear following flow diverter treatment. The aim of this study was to compare gene expression of various key molecules involved in the healing of aneurysms, between aneurysms treated with microcoils and flow diverters. Methods Saccular aneurysms were created in rabbits. Aneurysms were treated with coils (n=6) or flow diverters (n=6). Aneurysms were harvested at 4 weeks following treatment and used for gene expression and zymography experiments. Genes with a fold change of 1.2 or more were considered upregulated whereas those with a fold change of 0.8 or less were considered downregulated. Results All coil embolized aneurysms were completely occluded at follow-up. Two aneurysms were occluded and the remaining four samples were incompletely occluded in the flow diverter treated group. The following genes were expressed at lower levels in the flow diverter group compared with the coiled aneurysm group: proteinases (matrix metalloproteinases 2 and 9), cellular markers (endothelial nitric oxide synthase and smooth muscle actin), and structural proteins (collagens and fibronectin). Genes related to inflammation (tumor necrosis factor α and monocyte chemoattractant protein 1) were upregulated in flow diverter treated aneurysms compared with coil embolized aneurysms. Notably, the enzymatic activity of active matrix metalloproteinase 9 was high in aneurysms treated with flow diverters. Conclusions Our findings may provide improved understanding of rupture risk and healing following aneurysm treatment and inform development of therapies aimed at lowering rupture risk and accelerating healing.
Analysis of flow changes in side branches jailed by flow diverters in rabbit models

International Journal for Numerical Methods in Biomedical Engineering | April 14, 2014 | Volume: 30 | Issue: 10 | Pages: 988-999

10.1002/cnm.2640 | PMID 24729467

SUMMARYUnderstanding the flow alteration in side branches during flow diversion treatment of cerebral aneurysms is important to prevent ischemic complications and improve device designs. Flow diverters were placed in the aorta of four rabbits crossing the origin of side arteries. Subject‐specific computational models were constructed from 3D angiographies and Doppler ultrasounds (DUSs). Flow simulations were run before and after virtually deploying the flow diverters, assuming distal resistances remained unchanged after treatment. All jailed arteries remained patent angiographically 8 weeks after treatment. The computational models estimated decreases compared to pretreatment in the mean flow rates between 2% and 20% and in peak flow rates between 5% and 36%. The major changes were observed during systole. Flow patterns did not exhibit recirculation zones before treatment. Implantation of the flow diverters altered the flow structure only locally near the device wires. No major recirculation regions were created or destroyed. Flow diverters seem safe with respect to perforator or side branch occlusion. Relatively small changes in flow rates through jailed arteries are expected, even for moderate to large degrees of coverage of their origins. These results seem consistent with previous clinical experiences where no or very few complications related to perforator occlusion have been reported.Copyright © 2014 John Wiley & Sons, Ltd.
Hemodynamics of Elastase-Induced Aneurysms in Rabbit: A New High Flow Bifurcation Model

ASME 2011 Summer Bioengineering Conference, Parts A and B | July 17, 2013 | Volume: No volume available | Issue: No issue available | Pages: 267-268

10.1115/sbc2011-53819

An intracranial aneurysm (IA) is a pathological condition of cerebral arteries characterized by local enlargements of the arterial wall, typically into a saccular shape. Rupture of the aneurysm sac can result in devastating cerebral hemorrhage. Hemodynamic factors are believed to play an important role in initiation, development and rupture of IAs [1–3]. However, the coupling between hemodynamics and aneurysm pathophysiology is complex and remains poorly understood. Patient specific diagnostics regarding risk of rupture can be substantially advanced by improving our understanding of the in-vivo response of the aneurysm wall to intra-saccular hemodynamic stresses. A mechanism for fundamental studies of the impact of chronically altered WSS on the intact vascular wall is provided by animal models. However, cerebral aneurysms have not been shown to occur naturally in animals. Thus, a number of animal models have been created for studying aneurysm pathogenesis including those in mice, rats, rabbits, canines, swine and primates. To make meaningful use of these models, it is important to evaluate their relevance to human biomechanics and pathophysiology.