Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Temporal trends of survival and utilization of mechanical circulatory support devices in patients with in‐hospital cardiac arrest secondary to ventricular tachycardia/ventricular fibrillation
Catheterization and Cardiovascular Interventions | February 21, 2019 | Volume: 94 | Issue: 4 | Pages: 578-587
AbstractBackgroundPulseless ventricular tachycardia/ventricular fibrillation (VT/VF) is the initial rhythm in a third of in‐hospital cardiac arrest patients. Mechanical circulatory support (MCS) device use remains poorly understood in this population.MethodsWe conducted an observational analysis of temporal trends in the utilization of MCS in VT/VF IHCA between January 2008 and December 2014 utilizing the Nationwide Inpatient Sample (NIS) database. Using multivariable analysis, we assessed factors associated with MCS use and survival to discharge.ResultsAmong 151,628 hospitalizations with VT/VF IHCA, 14,981 (9.9%) received MCS. Intra‐aortic balloon pump (IABP) was the most commonly used MCS (9.1%). From 2008 to 2014, there was significant increase in the utilization of MCS (8.7–11%; ptrend < 0.0001). On multivariable analysis, there was 12‐fold increase and three‐fold increase in the utilization of PVAD and ECMO respectively; however, there was no significant change in the use of IABP. Over the seven‐year sample period, there was significant increase in the overall survival to hospital discharge (35.4–43.5%; ptrend < 0.0001). Survival to hospital discharge increased in both MCS and non‐MCS groups.ConclusionThere was significant increase in utilization of MCS after VT/VF IHCA during the study period. IABP was the most commonly utilized MCS. The survival to hospital discharge increased in the overall study population including both MCS and non‐MCS groups. Future studies are needed to identify patient population most likely to benefit from the use of MCS after VT/VF IHCA.