Citations 70

Autocorrection of Three-Dimensional Time-of-Flight MR Angiography of the Circle of Willis

American Journal of Roentgenology | February 28, 2013 | Volume: 176 | Issue: 2 | Pages: 513-518

10.2214/ajr.176.2.1760513 | PMID 11159106

Hepatic and splenic stiffness augmentation assessed with MR elastography in an in vivo porcine portal hypertension model

Journal of Magnetic Resonance Imaging | February 15, 2013 | Volume: 38 | Issue: 4 | Pages: 809-815

10.1002/jmri.24049 | PMID 23418135

PurposeTo investigate the influence of portal pressure on the shear stiffness of the liver and spleen in a well‐controlled in vivo porcine model with magnetic resonance elastography (MRE). A significant correlation between portal pressure and tissue stiffness could be used to noninvasively assess increased portal venous pressure (portal hypertension), which is a frequent clinical condition caused by cirrhosis of the liver and is responsible for the development of many lethal complications.Materials and MethodsDuring multiple intraarterial infusions of Dextran‐40 in three adult domestic pigs in vivo, 3D abdominal MRE was performed with left ventricle and portal catheters measuring blood pressure simultaneously. Least‐squares linear regressions were used to analyze the relationship between tissue stiffness and portal pressure.ResultsLiver and spleen stiffness have a dynamic component that increases significantly following an increase in portal or left ventricular pressure. Correlation coefficients with the linear regressions between stiffness and pressure exceeded 0.8 in most cases.ConclusionThe observed stiffness–pressure relationship of the liver and spleen could provide a promising noninvasive method for assessing portal pressure. Using MRE to study the tissue mechanics associated with portal pressure may provide new insights into the natural history and pathophysiology of hepatic diseases and may have significant diagnostic value in the future. J. Magn. Reson. Imaging 2013;38:809–815. © 2013 Wiley Periodicals, Inc.
Automated liver stiffness measurements with magnetic resonance elastography

Journal of Magnetic Resonance Imaging | December 21, 2012 | Volume: 38 | Issue: 2 | Pages: 371-379

10.1002/jmri.23980 | PMID 23281171

PurposeTo provide a fully automated algorithm for obtaining stiffness measurements from hepatic magnetic resonance elastography (MRE) images that are consistent with measurements performed by expert readers.Materials and MethodsAn initial liver contour was found using an adaptive threshold and expanded using an active contour to select a homogeneous area of the liver. The confidence map generated during the stiffness calculation was used to select a region of reliable wave propagation. The average stiffness within the automatically generated region of interest (ROI) was compared to measurements by two trained readers in a set of 88 clinical test cases ranging from healthy to severely fibrotic.ResultsThe stiffness measurements reported by the readers differed by −6.76% ± 22.8% (95% confidence) and had an intraclass correlation coefficient (ICC) of 0.972 (P < 0.05). The algorithm and the more experienced reader differed by 4.32% ± 14.9 with an ICC of 0.987.ConclusionThe automated algorithm performed reliably, even though MRE acquisitions often have motion artifacts present. The correlation between the automated measurements and those from the trained readers was superior to the correlation between the readers. J. Magn. Reson. Imaging 2013;38:371–379. © 2013 Wiley Periodicals, Inc.
Preoperative assessment of meningioma stiffness using magnetic resonance elastography

Journal of Neurosurgery | October 19, 2012 | Volume: 118 | Issue: 3 | Pages: 643-648

10.3171/2012.9.jns12519 | PMID 23082888

Object The object of this study was to determine the potential of magnetic resonance elastography (MRE) to preoperatively assess the stiffness of meningiomas. Methods Thirteen patients with meningiomas underwent 3D brain MRE examination to measure stiffness in the tumor as well as in surrounding brain tissue. Blinded to the MRE results, neurosurgeons made a qualitative assessment of tumor stiffness at the time of resection. The ability of MRE to predict the surgical assessment of stiffness was tested using a Spearman rank correlation. Results One case was excluded due to a small tumor size. In the remaining 12 cases, both tumor stiffness alone (p = 0.023) and the ratio of tumor stiffness to surrounding brain tissue stiffness (p = 0.0032) significantly correlated with the surgeons' qualitative assessment of tumor stiffness. Results of the MRE examination provided a stronger correlation with the surgical assessment of stiffness compared with traditional T1- and T2-weighted imaging (p = 0.089), particularly when considering meningiomas of intermediate stiffness. Conclusions In this cohort, preoperative MRE predicted tumor consistency at the time of surgery. Tumor stiffness as measured using MRE outperformed conventional MRI because tumor appearance on T1- and T2-weighted images could only accurately predict the softest and hardest meningiomas.
Magnetic resonance assessment of parenchymal elasticity in normal and edematous, ventilator-injured lung

Journal of Applied Physiology | June 8, 2012 | Volume: 113 | Issue: 4 | Pages: 666-676

10.1152/japplphysiol.01628.2011 | PMID 22678969

Magnetic resonance elastography (MRE) is a MR imaging method capable of spatially resolving the intrinsic mechanical properties of normal lung parenchyma. We tested the hypothesis that the mechanical properties of edematous lung exhibit local properties similar to those of a fluid-filled lung at transpulmonary pressures (Ptp) up to 25 cm H2O. Pulmonary edema was induced in anesthetized female adult Sprague-Dawley rats by mechanical ventilation to a pressure of 40 cm H2O for ∼30 min. Prior to imaging the wet weight of each ex vivo lung set was measured. MRE, high-resolution T1-weighted spin echo and T2* gradient echo data were acquired at each Ptpfor both normal and injured ex vivo lungs. At Ptps of 6 cm H2O and greater, the shear stiffness of normal lungs was greater than injured lungs ( P ≤ 0.0003). For Ptps up to 12 cm H2O, shear stiffness was equal to 1.00, 1.07, 1.16, and 1.26 kPa for the injured and 1.31, 1.89, 2.41, and 2.93 kPa for normal lungs at 3, 6, 9, and 12 cm H2O, respectively. For injured lungs MRE magnitude signal and shear stiffness within regions of differing degrees of alveolar flooding were calculated as a function of Ptp. Differences in shear stiffness were statistically significant between groups ( P < 0.001) with regions of lower magnitude signal being stiffer than those of higher signal. These data demonstrate that when the alveolar space filling material is fluid, MRE-derived parenchymal shear stiffness of the lung decreases, and the lung becomes inherently softer compared with normal lung.
Noise Reduction to Decrease Radiation Dose and Improve Conspicuity of Hepatic Lesions at Contrast-Enhanced 80-kV Hepatic CT Using Projection Space Denoising

American Journal of Roentgenology | January 19, 2012 | Volume: 198 | Issue: 2 | Pages: 405-411

10.2214/ajr.11.6987 | PMID 22268185

Two-dimensional shear elasticity imaging using comb-push acoustic radiation force and algebraic direct inversion of the motion differential equation

The Journal of the Acoustical Society of America | October 13, 2011 | Volume: 130 | Issue: 4_Supplement | Pages: 2424-2424

10.1121/1.3654715

Tissue mechanical properties can be obtained by algebraic direct inversion (ADI) of the shear-wave motion differential equation, which is insensitive to reflection and geometry of the pushing beam. Shear waves normally generated by a focused ultrasound pushing beam have limited spatial extent in depth and are transient in time, leading to noisy and unstable ADI results. A comb-shape acoustic radiation force distribution can generate shear waves with longer spatial extent and time duration, facilitating more robust ADI. For 400 μs, a linear array transducer simultaneously transmitted four unfocused pushing beams (12 on elements for each pushing beam, 8 off elements between beams) into a tissue-mimicking phantom (∼1.5 kPa) with a cylindrical inclusion (∼4 kPa). The ultrasound system (Verasonics Inc.) then immediately switched to flash imaging mode (frame rate = 2 kHz, spatial resolution = 0.31 mm) to measure shear-wave displacements in a 38 mm by 30 mm domain that was used for ADI. The reconstructed 2D shear elasticity map provides accurate shear elasticity estimates (background = 1.5 kPa with 7% variance; inclusion = 3.9 kPa with 15% variance) and excellent contrast between the background and inclusion.
High-Performance 3D Compressive Sensing MRI Reconstruction Using Many-Core Architectures

International Journal of Biomedical Imaging | September 15, 2011 | Volume: 2011 | Issue: No issue available | Pages: 1-11

10.1155/2011/473128 | PMID 21922017

Compressive sensing (CS) describes how sparse signals can be accurately reconstructed from many fewer samples than required by the Nyquist criterion. Since MRI scan duration is proportional to the number of acquired samples, CS has been gaining significant attention in MRI. However, the computationally intensive nature of CS reconstructions has precluded their use in routine clinical practice. In this work, we investigate how different throughput-oriented architectures can benefit one CS algorithm and what levels of acceleration are feasible on different modern platforms. We demonstrate that a CUDA-based code running on an NVIDIA Tesla C2050 GPU can reconstruct a 256 × 160 × 80 volume from an 8-channel acquisition in 19 seconds, which is in itself a significant improvement over the state of the art. We then show that Intel's Knights Ferry can perform the same 3D MRI reconstruction in only 12 seconds, bringing CS methods even closer to clinical viability.
IC‐P‐123: MR elastography of Alzheimer's disease

Alzheimer's & Dementia | August 1, 2011 | Volume: 7 | Issue: 4S_Part_2 | Pages: No page available

10.1016/j.jalz.2011.05.088

Dynamic Postprandial Hepatic Stiffness Augmentation Assessed With MR Elastography in Patients With Chronic Liver Disease

American Journal of Roentgenology | July 1, 2011 | Volume: 197 | Issue: 1 | Pages: 64-70

10.2214/ajr.10.5989 | PMID 21701012