Back to Authors

Amin, Mustapha

A5108236585 | I1316902750

Mayo Clinic

Cleveland Clinic

Citations 11

Catheter Ablation of Atrial Fibrillation in Adult Congenital Heart Disease: Procedural Characteristics and Outcomes

Circulation: Arrhythmia and Electrophysiology | July 24, 2023 | Volume: 16 | Issue: 8 | Pages: 437-446

10.1161/circep.122.011392 | PMID 37485717

BACKGROUND: The outcomes of catheter ablation for atrial fibrillation in adults with congenital heart disease are not well described. METHODS: In a retrospective study of adult patients with congenital heart disease who underwent catheter ablation for atrial fibrillation between 2000 and 2020 at Mayo Clinic, procedural characteristics and outcomes were collected. The primary outcomes were atrial arrhythmia (AA) recurrence following a 3-month blanking period and repeat ablation. An arrhythmia clinical severity score was assessed pre- and post-ablation based on the duration of arrhythmia episodes, symptoms, cardioversion frequency, and antiarrhythmic drug use. RESULTS: One hundred forty-five patients (age, 57±12 years; 28% female; 63% paroxysmal atrial fibrillation) underwent 198 ablations with a median follow-up of 26 months (interquartile range, 14–69). One hundred ten, 26, and 9 patients had simple, moderate, and complex congenital heart disease, respectively. All patients underwent pulmonary vein isolation, and non–pulmonary vein targets were ablated in 79 (54%). AA recurrence at 12 months was 37% (95% CI, 29%–45%). On univariate analysis, increasing left atrial volume index was associated with higher odds of AA recurrence (odds ratio, 1.03 [1.00–1.06] per 1 mL/m 2 increment; P =0.05). Noninducibility of atrial flutter was predictive of decreased odds of AA recurrence (odds ratio, 0.43 [0.21–0.90]; P =0.03). A second ablation was performed in 43 patients after a median of 20 (interquartile range, 8–37) months. Arrhythmia clinical severity scores improved following ablation, reflecting a decrease in symptoms, cardioversions, and antiarrhythmic drugs. CONCLUSIONS: Catheter ablation of atrial fibrillation is feasible and effective in patients with adult congenital heart disease and reduces symptoms. Recurrence of AA frequently requires repeat ablation.
Abstract 14310: Patient Reported Outcomes of Catheter Ablation for Atrial Fibrillation in Patients With Chronic Kidney Disease

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.14310

Introduction: Increasingly, catheter ablation for atrial fibrillation (AF) has been utilized for rhythm control and to improve quality of life (QoL). Data are limited on patient-centered ablation outcomes in individuals with chronic kidney disease (CKD). Objective: To examine clinical outcomes and QoL following AF ablation in CKD patients from a large patient-reported outcomes (PRO) database. Methods: All patients undergoing AF ablation (2013-2016) at our center were enrolled and assessed for outcomes using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). This analysis captured data at 1- and 3-year follow-up. CKD was defined as estimated glomerular filtration rate (eGFR) <60 ml/min using the 2021 CKD-EPI equation. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL assessment. In addition, data were collected on clinical improvement by patient report, AF burden, and healthcare utilization. Results: A total of 488 patients were identified (66% male, mean age 68.5, 56.2% persistent AF). QoL was significantly improved from baseline median (IQR) AFSSS of 14 (6-19.5) to 3 (0-9) at 1-year and 4 (0-9.5) at 3-year; P≤0.0001 for both. About 90% of patients reported improvement in their overall AF-related symptoms both at 1- and 3-year follow up. The proportion of patients in AF at the time of completion of the baseline survey was 51.2%, and this decreased to 6.2% at 1-year and 9.7% at 3-year follow up (P<0.0001 for both). AF burden was significantly reduced at 1-year and 3-year including frequency and duration of episodes (P<0.05 for both), with associated decrease in ER visits and hospitalizations; P<0.0001 for all comparisons. The proportion of patients on antiarrhythmics decreased from 61.8% at baseline to 35.6% and 22.7% at 1-year and 3-year, respectively (P<0.0001 for both). Conclusions: In a large AF-specific PRO system, catheter ablation for AF was associated with a significant improvement of QoL in most patients with CKD; with a decrease in AF burden and healthcare utilization.
Cardiac Implantable Electronic Devices in Ebstein Anomaly: Management and Outcomes

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010744 | PMID 35763435

Background: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. Methods: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. Results: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P =0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. Conclusions: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.
Catheter ablation of ventricular tachycardia in patients with postinfarction left ventricular aneurysm

Journal of Cardiovascular Electrophysiology | October 20, 2021 | Volume: 32 | Issue: 12 | Pages: 3156-3164

10.1111/jce.15273 | PMID 34664765

AbstractBackgroundWhile ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients.MethodsOur study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018.ResultsOf 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end‐diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low‐voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow‐up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all‐cause mortality at 1‐year follow‐up was 94%.ConclusionRadiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.
Super and Nonresponders to Catheter Ablation for Atrial Fibrillation: A Quality-of-Life Assessment Using Patient Reported Outcomes

Circulation: Arrhythmia and Electrophysiology | July 19, 2021 | Volume: 14 | Issue: 8 | Pages: No page available

10.1161/circep.121.009938 | PMID 34279998

Background: Atrial fibrillation (AF) ablation targets improvement in quality of life (QoL). Data is scarce on predictors of QoL improvement following ablation. We aimed to investigate the clinical characteristics underlying differential response in QoL after AF ablation (with or without arrhythmia recurrence). Methods: All patients undergoing AF ablation (2013–2016) at our center were prospectively enrolled in a fully automated patient-reported outcomes registry. A large number of variables were collected including AF symptom severity scale and AF burden (as indicated by AF frequency and duration scores). Patients were divided into 3 groups based on self-report of QoL improvement: remarkable (super responders), mild/moderate, and unchanged or worse (nonresponders). Univariable and multivariable logistic regression models assessed clinical characteristics and QoL outcomes. Results: A total of 956 patients were included (25% females, mean age 63.9). Most patients (≈80%) were super responders (n=761), 138 (14.4%) had mild/moderate improvement, and 57 (5.9%) were nonresponders. The strongest predictors of remarkable QoL improvement were freedom of arrhythmia recurrence (OR, 2.42 [95% CI, 1.27–4.59], P =0.007) and lower AF burden at 12 months. Similarly, higher AF burden was significantly associated with clinical nonresponse. In patients with observed clinical recurrence-QoL mismatch, changes in AF burden at 12 months were the main predictors of QoL outcome, with lower burden predicting higher improvement in QoL and vice versa. Conclusions: Most patients derive significant QoL benefit from AF ablation. Freedom from arrhythmia recurrence and lower AF burden predict remarkable QoL improvement following ablation.
A Systematic Review Supporting the American Society for Dermatologic Surgery Guidelines on the Prevention and Treatment of Adverse Events of Injectable Fillers

Dermatologic Surgery | February 22, 2021 | Volume: 47 | Issue: 2 | Pages: 227-234

10.1097/dss.0000000000002911 | PMID 33565776

BACKGROUND As the use of injectable skin fillers increase in popularity, an increase in the reported adverse events is expected. OBJECTIVE This systematic review supports the development of American Society for Dermatologic Surgery practice guideline on the management of adverse events of skin fillers. METHODS AND MATERIALS Several databases for studies on risk factors or treatments of injection-related visual compromise (IRVC), skin necrosis, inflammatory events, and nodules were searched. Meta-analysis was conducted when feasible. RESULTS The review included 182 studies. However, IRVC was very rare (1–2/1,000,000 patients) but had poor prognosis with improvement in 19% of cases. Skin necrosis was more common (approximately 5/1,000) with better prognosis (up to 77% of cases showing improvement). Treatments of IRVC and skin necrosis primarily depend on hyaluronidase injections. Risk of skin necrosis, inflammatory events, and nodules may be lower with certain fillers, brands, injection techniques, and volume. Treatment of inflammatory events and nodules with antibiotics, corticosteroids, 5-FU, and hyaluronidase was associated with high response rate (75%–80%). Most of the studies were small and noncomparative, making the evidence certainty very low. CONCLUSION Practitioners must have adequate knowledge of anatomy, elicit history of skin filler use, and establish preemptive protocols that prepare the clinical practice to manage complications.
Abstract 16741: A Comparison of High versus Conventional Power Radiofrequency Catheter Ablation for Pulmonary Vein Isolation: A Systematic Review and Meta-Analysis

Circulation | November 12, 2020 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.16741

Objectives: We sought to evaluate the procedural safety and outcomes of high power (HP) versus conventional power (CP) radiofrequency (RF) ablation during pulmonary vein isolation (PVI). Methods: A systematic search was used via MEDLINE, EMBASE, and Cochrane databases between 01/1998 and 05/2020 for studies comparing the safety and efficacy between HP and CP during RF ablation for PVI using contact-force catheters (ThermocoolSmartTouch or TactiCath). The search terms used were “AF” AND “catheter ablation” OR “radiofrequency ablation”. Results: From eight comparative observational studies, we developed a cohort of 992 patients (478 in the HP and 514 in the CP group). The median maximum energy output used in the HP group was 50W vs 35W in the CP group. There was a statistically significant difference noted in acute pulmonary vein reconnection (APVR) in the HP group compared to the CP groups at16% vs 32.6%, respectively (RR: 0.53, 95% CI: 0.33 - 0.86, P = 0.01). Freedom from arrhythmia at 12 months follow-up was also significant and found to be 87.8% of cases in the HP group versus75.2% of cases in the CP group (RR: 0.46, 95%CI: 0.32 - 0.65, P <0.01). The mean RF ablation time was 20.1 minutes in the HP group vs 39.6 minutes in the CP group (P <0.01). The mean total procedural time was 103.5 minutes in the HP group compared to 135 minutes in the CP group (P <0.01). Two patients in the CP group experienced severe adverse events (1 cardiac tamponade and 1 myocardial infarction). No serious AEs were found in the HP group. Non-serious AEs (groin complications, pericardial effusion, and phrenic nerve injury) were reported in 0.35% and 0.51% of cases in the HP and CP group, respectively. Conclusion: This study suggests that HP PVI ablation can be associated with better ablation outcomes by reducing the rate of acute and late PV reconnection and atrial arrhythmia recurrence, with similar safety profiles, and shorter procedural times. These findings merit evaluation in a randomized controlled trial.
Trends in reported industry payments to physicians practicing cardiac electrophysiology from 2013 to 2018 in the United States

Journal of Cardiovascular Electrophysiology | September 21, 2020 | Volume: 31 | Issue: 12 | Pages: 3106-3114

10.1111/jce.14754 | PMID 32955151

AbstractIntroductionThe need for transparency in financial relationships in the healthcare system, has culminated in Open Payments database, managed by the Center for Medicare and Medicaid Services (CMS). Since its inception in 2013, the trend in such payments to physicians practicing cardiac electrophysiology was not examined.Methods and ResultsPayment information reported to CMS from January 2013 to December 2018 was obtained from the publicly available Open Payments data set using the online query tool. The data were analyzed by an individual provider and by state. An in‐depth analysis of payments in the year 2018 payments was performed. From 2014 to 2018, there was an 18% increase in the total number of payments reported from 88 877 payments in 2014 to 105 000 in 2018. Despite the increase in the total number of payments reported, the average payment steadily decreased over time, resulting in an overall reduction in the total amount of payments from 2014 to 2018 ($34.9 million to $28.2 million). Payments to the top 5% of individual recipients have also decreased over this time. In 2018, 2888 unique providers received reportable payments, a total of 105 000 payments, with a median payment amount of $1378 (interquartile range: $165–$5781). The majority of these payments were for food and beverage (82%) and travel/lodging (10%). The top five payers include Boston Scientific, Medtronic Vascular, Abbott Laboratories, Janssen Pharmaceuticals, and Biotronik.ConclusionAmong cardiac electrophysiologists, there is increased reporting of payments in the Open Payments program over time, with a notable decrease in the payment amount.
Sudden cardiac arrest and ventricular arrhythmias following first type I myocardial infarction in the contemporary era

Journal of Cardiovascular Electrophysiology | October 7, 2019 | Volume: 30 | Issue: 12 | Pages: 2869-2876

10.1111/jce.14218 | PMID 31588605

AbstractIntroductionMyocardial infarction (MI) is associated with an increase in subsequent heart failure (HF), recurrent ischemic events, sudden cardiac arrest, and ventricular arrhythmias (SCA‐VA). The primary objective of the study to determine the role of intercurrent HF and ischemic events on the development of SCA‐VA following first type I MI.Methods and resultsA retrospective cohort study of patients experiencing first type 1 MI in Olmsted County, Minnesota (2002‐2012) was conducted by identifying patients using the medical records linkage system (Rochester epidemiology project). Patients aged ≥18 years were followed from the time of MI till death or 31 July, 2017. Intercurrent HF and ischemic events were the primary exposures following MI and their association with outcome SCA‐VA was assessed. Eight hundred and sixty‐seven patients (mean age was 63 ± 14.5 years; 69% male; 49.8% ST‐elevation myocardial infarction) who had their first type I MI during the study period were included. Majority of acute MI patients were revascularized using percutaneous coronary intervention and bypass surgery (628 [72.43%] and 87 [10.03%] respectively). During a mean follow‐up of 7.69 ± 4.17 years, HF, recurrent ischemic events and SCA‐VA occurred in 155 (17.9%), 245 (28.3%), and 40 (4.61%) patients respectively. Low ejection fraction (adjusted hazard ratio [HR] 0.95; 95% confidence interval [CI], 0.93‐0.98; P < .001), intercurrent HF (adjusted HR 3.11; 95% CI, 1.39‐6.95; P = .006) and recurrent ischemic events (adjusted HR 3.47; 95% CI, 1.68‐7.18; P < .001) were associated with subsequent SCA‐VA.ConclusionSCA‐VA occurred in a small proportion of patients after MI and is associated with intercurrent HF and recurrent ischemic events.
Efficacy of Pharmacologic and Cardiac Implantable Electronic Device Therapies in Patients With Heart Failure and Reduced Ejection Fraction

Circulation: Arrhythmia and Electrophysiology | June 4, 2019 | Volume: 12 | Issue: 6 | Pages: No page available

10.1161/circep.118.006951 | PMID 31159582

Background: The treatment of heart failure with reduced ejection fraction has been the subject of numerous randomized controlled trials involving medications and cardiac implantable electronic device therapies. As newer effective pharmacological therapies suggest significant reductions in all-cause mortality, the role of additional device therapy in heart failure with reduced ejection fraction deserves further scrutiny. Methods: A systematic review and network meta-analysis on the effect of medication and device therapies in heart failure with reduced ejection fraction on all-cause mortality was performed. Randomized controlled trials published between January 1980 and July 2017 were identified using Medline, EMBASE, and Cochrane Controlled Register of Trials databases. Pcnetmeta package in R was used to calculate treatment arm–based estimated rates, rate ratios, and probability ranks with 95% credible intervals. Results: Combination therapy of ACE (angiotensin-converting enzyme) inhibitors or ARBs (angiotensin receptor blockers) with β-blockers (BBs) alone or in addition to implantable cardiac defibrillators or cardiac resynchronization therapy with defibrillators demonstrated a significant reduction of all-cause mortality when compared with placebo. By probability rank, implantable cardiac defibrillator+ACE inhibitor or ARB+BB+mineralocorticoid receptor antagonist, implantable cardiac defibrillator+ACE inhibitor or ARB+BB, and angiotensin receptor-neprilysin inhibitor+BB+mineralocorticoid receptor antagonist combination therapies have the highest probability of being ranked the best treatment. There was no significant difference in the rate of mortality when comparing angiotensin receptor-neprilysin inhibitor+BB+mineralocorticoid receptor antagonist to implantable cardiac defibrillator+optimal pharmacological combination therapy. Conclusions: BB and renin-angiotensin system blockers alone or in combination with defibrillator device therapy have robust evidence for a reduction in mortality compared with placebo. The comparative efficacy of pharmacological therapy with angiotensin receptor-neprilysin inhibitors and device therapy deserves further investigation.