Citations

Mayo Clinic

Clear

176 citation(s) found for "Humphreys, M S".

Urine metabolic risk factors and outcomes of patients with kidney transplant nephrolithiasis
Bolen, Erin E., Stern, Karen , Humphreys, Mitchell R. , Brady, Alexandra, Leavitt, Todd, Zhang, Nan , Keddis, Mira T. , Bolen, Erin, Humphreys, Mitchell, Keddis, Mira , Stern, Karen L

Clinical Kidney Journal | October 16, 2021 | Volume: 15 | Issue: 3 | Pages: 500-506

10.1093/ckj/sfab208 | PMID 35211306 Get It

ABSTRACT Background Nephrolithiasis in allograft kidneys is rare, but this diagnosis may lead to allograft complications and patient morbidity. Previous studies that have evaluated nephrolithiasis posttransplant have focused on surgical stone management, with limited data on urine metabolic risk factors and the presence of stones after follow-up. Methods We retrospectively evaluated kidney transplant recipients who were diagnosed with transplant nephrolithiasis between 2009 and 2019. Computed tomography and ultrasound imaging were used to confirm stone presence. Results The incidence of allograft kidney stone formation was 0.86% of 6548 kidney transplant recipients. Of the 56 cases identified, 17 (30%) had a pretransplant history of nephrolithiasis. Only four (7%) patients received a known kidney stone at the time of allograft implantation. Of the 56 cases, 34 had a 24-h supersaturation study. The urine supersaturation study showed 32 patients (94%) had a urine citrate of <450 mg excreted in 24 h (median 124.5 mg/24 h, reference range >500 mg/24 h), along with 22 patients (61%) having a urine oxalate excretion of ≥30 mg in 24 h (median 34.4 mg/24 h, reference range <30 mg/24 h). Calcium oxalate composition was most common (91% with >1 supersaturation for calcium oxalate crystals), with normal median urine calcium levels (median urine calcium 103.5 mg/24 h, reference range <200 mg/24 h). After a 4-year follow-up, 50% (n = 28) required surgical intervention and 43 (77%) patients continued to have evidence of transplant nephrolithiasis on imaging. Conclusions This is the largest study of transplant nephrolithiasis confirming that hypocitraturia and hyperoxaluria were the most significant urine metabolic risk factors associated with allograft nephrolithiasis and that hyperoxaluria was the most prevalent driver for calcium oxalate stone composition. Our study is first to show low stone-free rates at the last follow-up and a significant proportion requiring surgical intervention.
Novel Variant in CLDN16: A Further Step in the Diagnosis of Familial Hypomagnesemia with Hypercalciuria and Nephrocalcinosis—A Case Report
Shimon, Tim, Hager, Megan M., Vairo, Filippo Pinto e , Keddis, Mira T. , Humphreys, Mitchell R. , Vairo, Filippo , Narang, Gopal , Moore, Jonathan, Stern, Karen

Uro | June 30, 2021 | Volume: 1 | Issue: 3 | Pages: 76-81

10.3390/uro1030011 Get It

Familial hypomagnesemia with hypercalciuria and nephrocalcinosis (FHHNC) is a rare tubulopathy characterized by renal loss of calcium and magnesium leading to progressive renal failure. The disorder is caused by variants to the tight junction proteins claudin-16 and -19. While rare, this disorder causes a significant burden to patients based on its clinical manifestations of various electrolyte abnormalities, nephrocalcinosis, and early progression to renal failure. In this report we describe the diagnosis of a novel variant of CLDN16 which clinically presented with severe hypomagnesemia, hypocalcemia, nephrocalcinosis, and renal failure.
Faculty Opinions recommendation of First In-Human Burst Wave Lithotripsy for Kidney Stone Comminution: Initial Two Case Studies.
Humphreys, Mitchell R. , Narang, Gopal

Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature | June 14, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.3410/f.738685997.793585856 Get It

Survey of Anesthesiologists on Topical Vasoconstrictors and Intravenous Tranexamic Acid for Endoscopic Sinus Surgery
Feng, Max , Lao, Veronica F., Bolton, Patrick , Marino, Michael J. , Humphreys, Ian M. , Dhillon, Sabrina, Choi, Byeong Yeob , Fernandez, Roman , Mehter, Najma S., Bolton, Patrick B., Marino, Michael J , Humphreys, Ian M , Chen, Philip G , Choby, Garret , Weingarten, Toby N. , Chen, Philip G.

Annals of Otology, Rhinology & Laryngology | April 12, 2021 | Volume: 131 | Issue: 1 | Pages: 59-70

10.1177/00034894211005940 | PMID 33840220 Get It

Objectives: Topical vasoconstrictors and intravenous tranexamic acid (IV TXA) are safe and efficacious to decrease bleeding and improve the surgical field during endoscopic sinus surgery (ESS). The purpose of this study was to investigate practice patterns, awareness of clinical evidence, and comfort levels among anesthesia providers regarding these hemostatic agents for ESS. Methods: A total of 767 attending anesthesiologists, residents, and certified registered nurse anesthetists (CRNAs) at 5 United States academic centers were invited to participate in a survey regarding their experience with IV TXA and 3 topical vasoconstrictor medications (oxymetazoline, epinephrine, and cocaine) during ESS. Results: 330 (47%) anesthesia providers responded to the electronic survey. 113 (97%) residents, 92 (83%) CRNAs, and 52 (68%) attendings managed 5 or fewer ESS cases per month. Two-thirds of providers had not reviewed efficacy or safety literature for these hemostatic agents. Oxymetazoline was perceived safest, followed by epinephrine, IV TXA, and cocaine. Respondents considered potential side effects over surgical field visibility when selecting agents. The majority of providers had no formal training on these agents for ESS, but indicated interest in educational opportunities. Conclusion: Many anesthesia providers are unfamiliar with safety and efficacy literature regarding agents used to improve hemostasis for ESS, highlighting a need for development of relevant educational resources. Rhinologic surgeons have an opportunity to communicate with anesthesia colleagues on the use of hemostatic agents to improve the surgical field during ESS.
Multi-Institutional Prospective Randomized Control Trial of Novel Intracorporeal Lithotripters: ShockPulse-SE vs Trilogy Trial
Large, Tim , Nottingham, Charles U. , Brinkman, Ethan , Agarwal, Deepak , Ferrero, Andrea , Sourial, Michael , Stern, Karen , Rivera, Marcelino , Knudsen, Bodo E. , Humphreys, Mitchel, Krambeck, Amy E. , Nottingham, Charles , Knudsen, Bodo , Stern, Karen L

Journal of Endourology | April 12, 2021 | Volume: 35 | Issue: 9 | Pages: 1326-1332

10.1089/end.2020.1097 | PMID 33843245 Get It

Introduction: Currently, there are multiple intracorporeal lithotripters available for use in percutaneous nephrolithotomy (PCNL). This study aimed to evaluate the efficiency of two novel lithotripters: Trilogy and ShockPulse-SE. Materials and Methods: This is a prospective multi-institutional randomized trial comparing outcomes of PCNL using two novel lithotripters between February 2019 and June 2020. The study assessed objective measures of stone clearance time, stone clearance rate, device malfunction, stone-free rates, and complications. Device assessment was provided through immediate postoperative survey by primary surgeons. Results: There were 100 standard PCNLs completed using either a Trilogy or ShockPulse-SE lithotrite. Using quantitative Stone Analysis Software to estimate stone volume, the mean stone volume was calculated at 4.18 ± 4.79 and 3.86 ± 3.43 cm 3 for the Trilogy and ShockPulse-SE groups, respectively. Stone clearance rates were found to be 1.22 ± 1.67 and 0.77 ± 0.68 cm 3 /min for Trilogy vs ShockPulse-SE ( p = 0.0542). When comparing Trilogy to ShockPulse-SE in a multivariate analysis, total operative room time (104.4 ± 48.2 minutes vs 121.1 ± 59.2 minutes p = 0.126), rates of secondary procedures (17.65% vs 40.81%, p = 0.005), and device malfunctions (1.96% vs 34.69%, p < 0.001) were less, respectively. There was no difference in final stone-free rates between devices. Conclusion: Both the Trilogy and ShockPulse-SE lithotripters are highly efficient at removing large renal stones. In this study, we noted differences between the two devices including fewer device malfunctions when Trilogy device was utilized. Clinical Trial ID number: NCT03959683
Holmium Laser Enucleation of the Prostate: A Description of the Fundamental Skills
Narang, Gopal , Abdul-Muhsin, Haidar , Humphreys, Mitchell R. , Cheney, Scott, Moore, Jonathan

Videourology™ | March 4, 2021 | Volume: 35 | Issue: 4 | Pages: No page available

10.1089/vid.2020.0132 Get It

SAGE-Journals-Accessible-Video-Player 10.1089/vid.2020.0132.M1 sj-vid-1-vid-10.1089_vid.2020.0132
Faculty Opinions recommendation of Tailoring Intensity of Active Surveillance for Low-Risk Prostate Cancer Based on Individualized Prediction of Risk Stability.
Humphreys, Mitchell R. , Narang, Gopal

Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature | January 5, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.3410/f.738564674.793581325 Get It

A Randomized Controlled Trial of Preoperative Prophylactic Antibiotics for Percutaneous Nephrolithotomy in Moderate to High Infectious Risk Population: A Report from the EDGE Consortium
Sur, Roger L. , Krambeck, Amy E. , Large, Tim , Bechis, Seth K. , Monga, Manoj , Hsi, Ryan S. , Miller, Nicole L. , Lange, Dirk , Knudsen, Bodo E. , Sourial, Michael , Humphreys, Mitchell R. , Stern, Karen , Shah, Ojas , Abbott, Joel E. , Abedi, Garen , Knudsen, Bodo, Stern, Karen L, Stern, Karen L , Hsi, Ryan , Friedlander, David Fallon , Chew, Ben H. , Miller, Nicole L

Journal of Urology | December 28, 2020 | Volume: 205 | Issue: 5 | Pages: 1379-1386

10.1097/ju.0000000000001582 | PMID 33369488 Get It

Device profile of the LithoVue single-use digital flexible ureteroscope in the removal of kidney stones: overview of safety and efficacy
Forbes, Connor M. , Lundeen, Colin , Beebe, Sarah C. , Knudsen, Bodo E. , Humphreys, Mitchell R. , Moore, Jonathan P, Moore, Jonathan P, Chew, Ben H. , Forbes, Connor M

Expert Review of Medical Devices | December 14, 2020 | Volume: 17 | Issue: 12 | Pages: 1257-1264

10.1080/17434440.2020.1848538 | PMID 33307869 Get It

Holmium laser enucleation of the prostate using Moses 2.0 vs non‐Moses: a randomised controlled trial
Nevo, Amihay , Faraj, Kassem , Cheney, Scott, Stern, Karen , Borofsky, Michael S. , Gnessin, Ehud , Humphreys, Mitchell R. , Faraj, Kassem S , Cheney, Scott M, Moore, Jonathan P, Stern, Karen L, Stern, Karen L , Moore, Jonathan P.

BJU International | December 4, 2020 | Volume: 127 | Issue: 5 | Pages: 553-559

10.1111/bju.15265 | PMID 33025749 Get It

Objectives To compare the enucleation efficiency of Moses 2.0 with non‐Moses technology in patients undergoing holmium laser enucleation of the prostate (HoLEP). Patients and Methods A double‐blinded, randomised study of patients undergoing HoLEP at the Mayo Clinic in Arizona, using the Lumenis Pulse™ 120H laser system. Patients were randomised to either right lobe enucleation using Moses 2.0 and left lobe enucleation using non‐Moses, or the opposite. The primary outcome was individual lobe enucleation efficiency. Secondary outcomes included individual lobe laser time, laser energy, individual enucleation and haemostasis laser energies, and fibre burn back. Two independent reviewers watched videos of the procedures and provided a subjective evaluation of the technologies. Results A total of 27 patients were included in the study. For the entire cohort, Moses 2.0 had less fibre degradation (3.5 vs 16.8 mm, P < 0.01) compared to non‐Moses. When HoLEP procedures were performed by an expert, Moses 2.0 resulted in shorter enucleation time (21 vs 36.7 min, P = 0.016) and higher enucleation efficiency (1.75 vs 1.05 g/min, P = 0.05) compared to non‐Moses. When HoLEP was performed by trainees, the Moses 2.0 cohort had a shorter haemostasis laser time (4.1 vs 9 min, P = 0.035) compared to the non‐Moses. Fibre degradation was lower with Moses 2.0 compared to non‐Moses for both experts and trainees. Moses 2.0 received a higher score than the standard technology for the incision sharpness, fibre control, tissue separation, tissue damage, haemostasis, visibility, and charring. The overall inter‐observer correlation coefficient was 0.63. Conclusion Moses 2.0 has higher enucleation efficiency compared to non‐Moses when used by experts. The subjective evaluation favoured Moses 2.0.