Citations

Mayo Clinic

Clear

24 citation(s) found for "Gurudu, S".

Automatic polyp detection in colonoscopy videos
Yuan, Zijie, Izadyyazdanabadi, Mohammadhassan , Mokkapati, Divya, Panvalkar, Rujuta, Shin, J. , Tajbakhsh, Nima , Gurudu, Suryakanth, Liang, Jianming , Shin, Jae Y.

SPIE Proceedings | February 27, 2017 | Volume: 10133 | Issue: No issue available | Pages: 101332K

10.1117/12.2254671 Get It

Postcolonoscopy Followup Recommendations: Comparison with and without Use of Polyp Pathology
Ratuapli, Shiva K., Gurudu, Suryakanth, Atia, Mary A., Umar, Sarah B. , Harrison, M. Edwyn , Leighton, Jonathan A. , Ramirez, Francisco C. , Linder, Jeffrey A. , Gurudu, Suryakanth R, Crowell, Michael D.

Diagnostic and Therapeutic Endoscopy | August 27, 2014 | Volume: 2014 | Issue: No issue available | Pages: 1-7

10.1155/2014/683491 | PMID 25242879 Get It

Background. Appropriate recommendations for a followup exam after an index colonoscopy are an important quality indicator. Lack of knowledge of polyp pathology at the time of colonoscopy may be one reason that followup recommendations are not made. Aim. To describe and compare the accuracy of followup recommendations made at colonoscopy based on the size and number of polyps with recommendations made at a later date based on actual polyp pathology. Methods. All patients who underwent screening and surveillance colonoscopy from March, 2012, to August, 2012, were included. Surveillance recommendations from the endoscopy reports were graded as “accurate” or “not accurate” based on the postpolypectomy surveillance guidelines established by US Multisociety Task Force on Colon Cancer. Polyp pathology was then used to regrade the surveillance recommendations. Results. Followup recommendations were accurate in 759/884 (86%) of the study colonoscopies, based upon size and number of polyps with the assumption that all polyps were adenomatous. After incorporating actual polyp pathology, 717/884 (81%) colonoscopies had accurate recommendations. Conclusion. In our practice, the knowledge of actual polyp pathology does not change the surveillance recommendations made at the time of colonoscopy in the majority of patients.
Capsule Endoscopy in Patients with Implantable Electromedical Devices is Safe
Harris, Lucinda A. , Hansel, Stephanie L. , Rajan, Elizabeth , Rea, Robert F., Crowell, Michael D. , Fleischer, David E., Pasha, Shabana F., Gurudu, Suryakanth, Heigh, Russell I., Shiff, Arthur D., Post, J, Leighton, Jonathan A. , Srivathsan, Komandoor , Crowell, Michael D , Hansel, Stephanie L

Gastroenterology Research and Practice | April 3, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-5

10.1155/2013/959234 | PMID 23710168 Get It

Background and Study Aims. The presence of an implantable electromechanical cardiac device (IED) has long been considered a relative contraindication to the performance of video capsule endoscopy (CE). The primary aim of this study was to evaluate the safety of CE in patients with IEDs. A secondary purpose was to determine whether IEDs have any impact on images captured by CE.Patients and Methods.A retrospective chart review of all patients who had a capsule endoscopy at Mayo Clinic in Scottsdale, AZ, USA, or Rochester, MN, USA, (January 2002 to June 2010) was performed to identify CE studies done on patients with IEDs. One hundred and eighteen capsule studies performed in 108 patients with IEDs were identified and reviewed for demographic data, method of preparation, and study data.Results.The most common indications for CE were obscure gastrointestinal bleeding (77%), anemia (14%), abdominal pain (5%), celiac disease (2%), diarrhea (1%), and Crohn’s disease (1%). Postprocedure assessments did not reveal any detectable alteration on the function of the IED. One patient with an ICD had a 25-minute loss of capsule imaging due to recorder defect. Two patients with LVADs had interference with capsule image acquisition.Conclusions.CE did not interfere with IED function, including PM, ICD, and/or LVAD and thus appears safe. Additionally, PM and ICD do not appear to interfere with image acquisition but LVAD may interfere with capsule images and require that capsule leads be positioned as far away as possible from the IED to assure reliable image acquisition.
Using CT Enterography to Monitor Crohn's Disease Activity: A Preliminary Study
Hara, Amy K., Alam, Shayan, Heigh, Russell I., Gurudu, Suryakanth, Hentz, Joseph G. , Leighton, Jonathan A.

American Journal of Roentgenology | May 20, 2008 | Volume: 190 | Issue: 6 | Pages: 1512-1516

10.2214/ajr.07.2877 | PMID 18492900 Get It