Citations

Mayo Clinic

Clear

24 citation(s) found for "Daher, Ghazal".

American Cochlear Implant Alliance Task Force Guidelines for Clinical Assessment and Management of Adult Cochlear Implantation for Single-Sided Deafness
Kocharyan, Arminé , Daher, Ghazal S. , Carlson, Matthew L. , Shapiro, William H., Snapp, Hillary , Firszt, Jill B. , Dillon, Margaret T.

Ear & Hearing | August 22, 2022 | Volume: 43 | Issue: 6 | Pages: 1605-1619

10.1097/aud.0000000000001260 | PMID 35994570 Get It

The indications for cochlear implantation have expanded to include individuals with profound sensorineural hearing loss in the impaired ear and normal hearing (NH) in the contralateral ear, known as single-sided deafness (SSD). There are additional considerations for the clinical assessment and management of adult cochlear implant candidates and recipients with SSD as compared to conventional cochlear implant candidates with bilateral moderate to profound sensorineural hearing loss. The present report reviews the current evidence relevant to the assessment and management of adults with SSD. A systematic review was also conducted on published studies that investigated outcomes of cochlear implant use on measures of speech recognition in quiet and noise, sound source localization, tinnitus perception, and quality of life for this patient population. Expert consensus and systematic review of the current literature were combined to provide guidance for the clinical assessment and management of adults with SSD.
Underreporting and Underrepresentation of Race and Ethnicity in Head and Neck Cancer Trials, 2010-2020
Sauer, Adam , Daher, Ghazal S. , Lohse, Christine M. , Glasgow, Amy E. , Douse, Dontre’ M. , Moore, Eric J. , Ighodaro, Eseosa T. , Abel, Kathryn M. Van , Glasgow, Amy E. , Sauer, Adam B, Van Abel, Kathryn M , Glasgow, Amy E , Habermann, Elizabeth B. , Yin, Linda X.

JAMA Otolaryngology–Head & Neck Surgery | June 2, 2022 | Volume: 148 | Issue: 7 | Pages: 662

10.1001/jamaoto.2022.1028 | PMID 35653143 Get It

Hearing Preservation in Observed Sporadic Vestibular Schwannoma: A Systematic Review
Khandalavala, Karl R., Saba, Elias S., Kocharyan, Armine, Daher, Ghazal S., Lohse, Christine M., Marinelli, John P., Carlson, Matthew L., Khandalavala, Karl R., Saba, Elias S., Kocharyan, Armine, Daher, Ghazal S., Lohse, Christine M., Marinelli, John P., Carlson, Matthew L.

Otology & Neurotology | March 9, 2022 | Volume: 43 | Issue: 6 | Pages: 604-610

10.1097/mao.0000000000003520 | PMID 35261385 Get It

Objective To characterize the natural history of hearing loss for patients presenting with serviceable hearing (SH) who undergo a wait-and-scan approach for sporadic vestibular schwannoma (VS) using aggregate time-to-event survival analysis. Study Design Systematic review. Setting Published international English literature, January 1, 2000 to May 31, 2020. Patients Patients with sporadic VS entering a wait-and-scan approach with SH at diagnosis. Interventions Observation with serial MRI and audiometry. Results In total, 3,652 patients from 26 studies were included for analysis. Mean age at diagnosis was 58.8 years (SD, 4.1). Mean follow-up was 49.2 months (SD, 26.5). In total, 755 patients (21%) failed conservative treatment and underwent radiosurgery or microsurgery at the time of last follow-up. The average loss to follow-up was 6.9% (SD, 11.1). A total of 1,674 patients had SH at the time of diagnosis. Survival rates for maintaining SH were 96% at 1 year, 77% at 3 years, 62% at 5 years, and 42% at 10 years following diagnosis. Conclusion In this systematic review, aggregate data from 3,652 patients across 26 studies show consistent patterns in progression of hearing loss during observation for patients with sporadic VS as a function of time. As an easy-toremember conservative benchmark for those presenting with SH at diagnosis: approximately 75% retain SH at 3 years, 60% at 5 years, and 40% at 10 years.
Intraoperative Use of Electrical Stapedius Reflex Testing for Cochlear Nerve Monitoring During Simultaneous Translabyrinthine Resection of Vestibular Schwannoma and Cochlear Implantation
Kocharyan, Armine, Daher, Ghazal S., Nassiri, Ashley M., Khandalavala, Karl R., Saoji, Aniket A., Gompel, Jamie J. Van, Carlson, Matthew L., Kocharyan, Armine, Daher, Ghazal S., Nassiri, Ashley M., Khandalavala, Karl R., Saoji, Aniket A., Gompel, Jamie J. Van, Carlson, Matthew L.

Otology & Neurotology | February 23, 2022 | Volume: 43 | Issue: 4 | Pages: 506-511

10.1097/mao.0000000000003505 | PMID 35195569 Get It

Objective: To report the novel use of intraoperative electrically evoked stapedial reflex (eSR) for cochlear nerve monitoring during simultaneous translabyrinthine resection of vestibular schwannoma (VS) and cochlear implantation. Study Design: Clinical capsule report with video demonstration. Setting: Tertiary academic referral center. Patient: A 58-year-old female presented with a small right intracanalicular VS with associated asymmetrical right moderate to severe sensorineural hearing loss, poor word recognition, tinnitus, and disequilibrium. Based on patient symptomatology and goals, simultaneous CI with translabyrinthine resection of the VS was performed. Intervention: Cochlear implantation before the tumor was resected facilitated intraoperative eSRs by delivering repeated single-electrode stimulations through the cochlear implant (CI) electrode during tumor resection. A pulse duration of 50-us and a current amplitude of 200-CL or 648-us was used to elicit eSRs visible through the facial recess. Intraoperative eSR was monitored in conjunction with electrically evoked compound action potentials via neural response telemetry and electrical auditory brainstem response. Results: Despite the transient evoked compound action potentials amplitude and electrical auditory brainstem response latency changes, the visually observed eSR was preserved and remained robust throughout tumor dissection, indicating an intact cochlear nerve. Four weeks postoperatively, the patient exhibited open-set speech capacity (14% CNC and 36% AzBio in quiet). Conclusion: The current study demonstrates the feasibility of using intraoperative eSR via a CI electrode to monitor cochlear nerve integrity during VS resection, which may indicate successful CI outcomes. These preliminary findings require further substantiation in a larger study.