The objective of this study was to investigate the influence of pore geometry on the transport rate and depth after repetitive mechanical deformation of porous scaffolds for tissue engineering applications. Flexible cubic imaging phantoms with pores in the shape of a circular cylinder, elliptic cylinder, and spheroid were fabricated from a biodegradable polymer blend using a combined 3D printing and injection molding technique. The specimens were immersed in fluid and loaded with a solution of a radiopaque solute. The solute distribution was quantified by recording 20 μm pixel-resolution images in an X-ray microimaging scanner at selected time points after intervals of dynamic straining with a mean strain of 8.6 ± 1.6% at 1.0 Hz. The results show that application of cyclic strain significantly increases the rate and depth of solute transport, as compared to diffusive transport alone, for all pore shapes. In addition, pore shape, pore size, and the orientation of the pore cross-sectional asymmetry with respect to the direction of strain greatly influence solute transport. Thus, pore geometry can be tailored to increase transport rates and depths in cyclically deformed scaffolds, which is of utmost importance when thick, metabolically functional tissues are to be engineered.
The number of osteoporotic hip fractures is projected to increase two to three fold in the next 30years. This will lead to increased mortality and nursing home placement with significant costs to our society. Although in clinical trials drug and hormone therapies have shown an important decrease in fracture risk there is a significant role of surgical implantation treatments to further reduce the risk in specific subpopulations. Strength testing was completed on four pairs of osteoporotic, two pairs of osteopenic, and two pairs of normal cadaver femurs. The fracturing was recorded with a video camera at 4000 frames per second. The specially designed test fixture was instrumented with three load cells to measure the femoral forces. Force and moment data were recorded simultaneously and correlated with the frames. The fracture force at the greater trochanter was used to characterize the strength of implanted∕nonimplanted osteoporotic femurs. All femurs began fracturing within about 60ms at a test speed of 100mm∕s. During the first 20ms, the relationship between force and displacement was nonlinear, but linear thereafter until the fracture occurs. The fracture events resolved completely within 10–20ms. The average strength increase of the implanted femurs was 79% compared to the nonimplanted controls. The simultaneous acquisition of fracture images and load data is a powerful tool to understand and characterize numerically the femoral fracture. This methodology allows the researcher to define the best metrics to compare competing reinforcement materials, implant designs and surgical procedures.