Abstract Background There is limited evidence supporting the use of alternative treatments for patients with nonstable vitiligo. Objective This study aimed to review the effects of oral mini‐pulse (OMP) therapy in the management of nonsegmental vitiligo. Methods The following databases were searched between inception and May 2020 for relevant studies: Scopus, Web of Science, MEDLINE, and Embase. All randomized controlled trials that compared OMP therapy with any other active treatment or placebo for nonstable vitiligo were included. The Cochrane’s risk of bias tool was used to evaluate the risk of bias (ROB) in selected studies, and the overall quality of evidence of each outcome was assessed using the Grading Recommendations, Assessment, Development, and Evaluations (GRADE) system. Results Four studies met our selection criteria. All of them were conducted in India and included 246 patients. OMP therapy included betamethasone or dexamethasone. The duration of treatment was 6 months in all studies. Up to 32% of patients achieved a repigmentation rate of >75% when OMP therapy was administered as monotherapy. No difference was observed between OMP therapy and other treatments in arresting the disease, and weight gain was the most frequent adverse effect. The overall ROB in all included studies was relatively high because of the randomization process, outcome measurement and informed selection of outcomes. Conclusion Based on the findings of these studies, OMP therapy did not demonstrate additional value compared with other treatments. Hence, there is an urgent need to conduct high‐quality clinical trials to evaluate this therapy.
Behavioral Counseling Interventions to Promote a Healthy Diet and Physical Activity for Cardiovascular Disease Prevention in Adults With Cardiovascular Risk Factors
AbstractBackground/ObjectivesPatients with rare diseases are challenged when it comes to finding physicians with expertise in their condition. The Foundation for Ichthyosis and Related Skin Types (FIRST) Tele‐Ichthyosis program has provided telemedicine for patients and their families with keratinizing disorders since 2009. This study aims to characterize a decade of experience with the program.MethodsThis retrospective cohort study analyzed cases for demographics of patients and the clinicians who submitted their cases, nature of questions asked, number of expert responses, and characteristics of responses. Surveys were sent electronically to all users of the FIRST Tele‐Ichthyosis service to assess experiences with the service and solicit constructive recommendations. Descriptive statistics were performed on the case review and responder surveys.ResultsEighty‐eight geographically diverse cases were reviewed showing increased use over time by various specialists for patients of all ages. Sixty‐six percent of cases were definitively ichthyosis, and most submitters queried on diagnosis (47%) or treatment (72%). Most submitters described the service as easy to use (66.6%) and advice as timely (61.1%), clear (66.6%), and beneficial (61.1%). All submitters made suggestions for improvement (100%). Experts predominately worked with pediatric populations (70%) and reported self‐motivation to volunteer and improve patients’ lives (100%). Experts found technological barriers minor and provided feedback to enhance the service.ConclusionsThis report highlights how a rare‐disease patient advocacy group successfully supports physician collaboration and patient outcomes through secure and efficient telemedicine. Lessons learned are highly relevant in the current healthcare environment.
Abstract 15069: Long Term Heart Failure Risk in Zika Myocarditis
Introduction: It has been estimated that up to a billion people worldwide could be exposed to Zika re-emergence including North America. Zika was considered the worst outbreak of the century before COVID-19. There are only few reports of cardiac complications and the long-term risk of heart failure (HF) is unknown. This is the objective of this study. Methods: We included 19 patients who developed acute myocarditis within one week of symptomatic Zika, in a prospective observational multi-center study. Patients underwent clinical, laboratory evaluation including Zika confirmation, ECG, echocardiogram, Holter, cardiac MRI, coronary arteriography (2). Patient follow-up examinations were performed at 2, 6,12, 24, 36 and 48 months. Results: Of the 19 patients, 12 (63%) were female with a mean age of 49 ± 17 years with a median follow-up of 3 years. Nine patients (47%) developed acute HF; 8 (42%) with reduced ejection fraction (HFrEF) and one with preserved EF (HFrEF) and moderate to severe pericardial effusion. Two cases died suddenly in the first week of Zika onset, both with HFrEF. Treatment included sacubitril /valsartan, or ace-inhibitors, SGLT2 inhibitors, beta-blockers, aldosterone-blockers, cardiovascular rehabilitation, and in one case cardiac resynchronization therapy plus implanted defibrillator. There was no new HF onset after the acute phase of the disease. Myocarditis resolved in 10 (56%) patients. Persistent atrial and ventricular arrhythmia with normal EF observed in 5 (26%) of cases. Altogether, characteristic features of dilated cardiomyopathy that developed in 7 patients (36, 8%); 2 (11%) of them died. Conclusion: Almost half of the patients with Zika myocarditis developed acute HF during the first week of disease onset, none of the patients developed HF after the acute phase. A 3-year mortality rate of 10,5 % was observed.
Screening for High Blood Pressure in Children and Adolescents
BACKGROUND: Subjective evaluations to confirm recovery from neuromuscular blockade with a peripheral nerve stimulator (PNS) is inadequate. Quantitative monitors are the only reliable method to confirm adequate recovery of neuromuscular function. Unfortunately, many clinicians are unfamiliar with such devices and there is concern that the introduction of objective monitoring would be exceedingly laborious and could cause workflow delays. This study investigates how long it takes experienced nurse anesthetists to apply various neuromuscular devices as well as their perception regarding the ease of application. METHODS: Twenty nurse anesthetists were consented and participated in an educational session that familiarized them with 3 devices: SunStim Plus PNS (SunMed, Grand Rapids, MI), the acceleromyography-based IntelliVue NMT device (Philips, Amsterdam, the Netherlands), and electromyography-based TetraGraph device (Senzime B.V., Uppsala, Sweden). Participants were timed while placing each monitor on patients in a real-world setting. For the quantitative devices (IntelliVue NMT and TetraGraph), participants were also timed when obtaining calibrated baseline train-of-four (TOF) ratios. Friedman test and pairwise Wilcoxon signed-rank tests were used to evaluate the difference in time to connect different devices. Participants were surveyed about how easy they found it to utilize these devices. RESULTS: After adjusting for multiple comparison, time to connect was significantly less for PNS (median, 29; range, 16–58 seconds) compared to either the TetraGraph device (median, 62.8; range, 32–101 seconds; P < .001) or the IntelliVue NMT device (median, 46; range: 28–90 seconds; P < .001). The difference in time to connect between the TetraGraph device and the IntelliVue NMT device was not statistically significant ( P = .053), but it took significantly less time to calibrate the TetraGraph device than the IntelliVue NMT device (median difference, −16; range, −88 to 49 seconds; P = .002). The participants found applying either the IntelliVue NMT device ( P = .042) or the TetraGraph device ( P = .048) more difficult than applying a PNS while finding it easier to calibrate the TetraGraph device versus the IntelliVue NMT device ( P < .001). CONCLUSIONS: It takes 19 seconds longer to apply a quantitative neuromuscular monitor (the IntelliVue NMT device) than a PNS. While this difference reached significance, this relatively minimal additional time represents an inappropriate barrier to the application of quantitative monitors. Regardless of which quantitative monitor was utilized, these nurse anesthetists found the application and utilization of such devices relatively straightforward.