Purpose: To evaluate the outcomes of the Gore Excluder Iliac Branch Endoprosthesis (IBE) using division branches of the internal iliac artery (IIA) as distal landing zones. Materials and Methods: Between January 1, 2014, and December 31, 2018, 74 patients (mean age 74±7 years; 72 men) treated for aortoiliac or common iliac artery aneurysms had an IBE deployed with distal landing of the side branch within the main trunk (n=60) of the internal iliac artery (IIA) vs within a division branch (n=25). Thirteen (17%) patients received bilateral IBE implantations for a total of 85 vessels evaluated. Early endpoints were technical success, 30-day mortality, 30-day major adverse events (MAEs), and 30-day major access complications. Late endpoints were survival, primary and secondary IIA patency, freedom from IIA branch instability, freedom from new-onset buttock claudication, and aneurysm sac diameter changes. Time-dependent outcomes were reported as Kaplan-Meier curves with differences assessed using the log-rank test. Estimates are presented with the 95% confidence interval (CI). Results: The overall technical success rate was 97%, with 1 technical failure per group (p=0.43). Two patients, one from each group, died within 30 days (p=0.43). No significant differences were seen in the rates of 30-day MAEs (7% vs 17%, p=0.35) or major access complications (9% vs 11%, p>0.99) for patients receiving distal landing in the main trunk vs a division branch, respectively. The mean follow-up for the entire cohort was 19±12 months. The overall 1-year survival rate was 94% (95% CI 74% to 99%). The primary and secondary patency rates at 1 year were 98% (95% CI 88% to 99%) vs 95% (95% CI 72% to 99%, p=0.72) and 98% (95% CI 88% to 99%) vs 100% (p=0.41) for the main trunk vs division branch groups, respectively. Freedom from IIA branch instability estimates were also similar at 1-year follow-up [93% (95% CI 82% to 97%) vs 90% (95% CI 66% to 97%), p=0.29], as were the freedom from new-onset buttock claudication estimates [98% (95% CI 86% to 99%) and 94% (95% CI 67% to 99%), respectively; p=0.62]. Mean sac diameter change was 5.4±5.3 mm, not significantly different between the groups (p=0.85). Conclusion: Use of the posterior or anterior division of the IIA as a distal landing zone for the Gore Excluder IBE was safe and efficacious in the midterm. This technique may permit extending indications for endovascular repair of aortoiliac aneurysms to cases with unsuitable anatomy within the IIA main trunk. Long-term assessment is needed to affirm the efficacy of this technique.
Expanding the Anatomical Feasibility of Branched Stent-Grafts in Patients With Variant Visceral Vessel Anatomy
Purpose: To demonstrate the feasibility of a physician-modified endograft (PMEG) with inner branches for 2 mesenteric arteries as an alternative to fenestrations or directional branches. Technique: A symptomatic 60-year-old man presented with supraceliac para-anastomotic pseudoaneurysm involving an antegrade aorta to celiac artery and superior mesenteric artery bypass. Since an off-the-shelf multibranched endograft was inappropriate, a Zenith Alpha thoracic stent-graft was modified with 2 inner branches fashioned of 8-mm Viabahn endoprostheses with preloaded guidewires. The procedure was technically successful, and the patient had no postoperative complications. Conclusion: Inner branches might offer an alternative to fenestrations or directional branches in patients with narrow aortas.
Up-and-Over Technique for Implantation of Iliac Branch Devices After Prior Aortic Endograft Repair
Purpose: To describe a modified up-and-over access technique for treatment of iliac artery aneurysms in patients with prior bifurcated stent-grafts for endovascular aneurysm repair (EVAR). Technique: This technique uses a coaxial 12-F flexible sheath that is docked with a through-and-through wire into a 7-F sheath advanced from the contralateral femoral approach. This maneuver allows both sheaths to be moved as a unit while maintaining position of the apex of the system as it loops over the flow divider, avoiding damage to or displacing the extant endograft. Once the 12-F sheath is positioned in the iliac limb of the aortic stent-graft and secured in place with the through-and-through wire, the repair is extended into the internal iliac artery using a bridging stent-graft or covered stent introduced via a coaxial sheath. Conclusion: The up-and-over technique with a flexible 12-F sheath mated with a 7-F sheath from the opposite side allows bilateral femoral access to be used for iliac branch device placement after prior aortic endograft procedures that create a higher, acutely angled bifurcation. Use of a through-and-through wire and a coaxial sheath for stent delivery creates a very stable platform for intervention.