Left ventricle assist device pulsatility index at the time of implantation is associated with follow-up pulmonary hemodynamics
Sajgalik, Pavol , Kushwaha, Sudhir S. , Olson, Lyle J. , Stulak, John M., Johnson, Bruce D. , Schirger, John A., Schaefer, Jacob J

The International Journal of Artificial Organs | January 27, 2020 | Volume: 43 | Issue: 7 | Pages: 452-460

10.1177/0391398819899403 Get It

HeartMate II left ventricular assist device controllers provide data including pulsatility index, reflecting the relationship between pump function and hemodynamics. We propose that a higher pulsatility index at hospital discharge following implant may be associated with less vascular congestion and improved clinical outcomes. A retrospective analysis of 40 patients (age 59.2 ± 10.3 years) supported with the HeartMate II devices was conducted. Data revealed moderate Pearson correlations between pulsatility index at discharge and right atrial pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, mean pulmonary arterial pressure, and pulmonary capillary wedge pressure, respectively, post-surgery (median of 377 days), demonstrating a stronger relationship when analyzed for the EPC controller (n = 28) only (r = −.57, p < .01; r = −.38, p < .05; r = −.59, p < .01; r = −.47, p = .01 and r = −.53, p < .01, respectively). The pulsatility index derived from the EPC controller was associated with the significant risk of re-hospitalization within 1 and 2 years after the implantation of left ventricular assist device; hazard ratio = 0.557 with 95% confidence interval (0.315–0.983), p = .04 and hazard ratio = .579 (0.341–0.984), p = .04. A higher pulsatility index at discharge was associated with greater volume unloading, lower pulmonary pressures, and lower risk of all-cause re-hospitalizations within 1 and 2 years post-surgery. As such, pump-derived data may provide additional value in predicting left ventricular assist device hemodynamics.
Dissociating the effects of oxygen pressure and content on the control of breathing and acute hypoxic response
Dominelli, Paolo B. , Baker, Sarah E. , Wiggins, Chad C. , Stewart, Glenn M. , Sajgalik, Pavol , Shepherd, John R. A. , Roberts, Shelly K., Roy, Tuhin K. , Curry, Timothy B. , Hoyer, James D., Oliveira, Jennifer L. , Herrick, Jennifer L. , Foster, Glen E , Wiggins, Chad C , Roy, Tuhin K , Baker, Sarah E , Foster, Glen E. , Joyner, Michael J.

Journal of Applied Physiology | October 24, 2019 | Volume: 127 | Issue: 6 | Pages: 1622-1631

10.1152/japplphysiol.00569.2019 Get It

Arterial oxygen tension and oxyhemoglobin saturation ([Formula: see text]) decrease in parallel during hypoxia. Distinguishing between changes in oxygen tension and oxygen content as the relevant physiological stimulus for cardiorespiratory alterations remains challenging. To overcome this, we recruited nine individuals with hemoglobinopathy manifesting as high-affinity hemoglobin [HAH; partial pressure at 50% [Formula: see text] (P50) = 16 ± 0.4 mmHg] causing greater [Formula: see text] at a given oxygen partial pressure compared with control subjects ( n = 12, P50 = 26 ± 0.4 mmHg). We assessed ventilatory and cardiovascular responses to acute isocapnic hypoxia, iso-oxic hypercapnia, and 20 min of isocapnic hypoxia (arterial Po2 = 50 mmHg). Blood gas alterations were achieved with dynamic end-tidal forcing. When expressed as a function of the logarithm of oxygen partial pressure, ventilatory sensitivity to hypoxia was not different between groups. However, there was a significant difference when expressed as a function of [Formula: see text]. Conversely, the rise in heart rate was blunted in HAH subjects when expressed as a function of partial pressure but similar when expressed as a function of [Formula: see text]. Ventilatory sensitivity to hypercapnia was not different between groups. During sustained isocapnic hypoxia, the rise in minute ventilation was similar between groups; however, heart rate was significantly greater in the controls during 3 to 9 min of exposure. Our results support the notion that oxygen tension, not content, alters cellular Po2in the chemosensors and drives the hypoxic ventilatory response. Our study suggests that in addition to oxygen partial pressure, oxygen content may also influence the heart rate response to hypoxia.NEW & NOTEWORTHY We dissociated the effects of oxygen content and pressure of cardiorespiratory regulation studying individuals with high-affinity hemoglobin (HAH). During hypoxia, the ventilatory response, expressed as a function of oxygen tension, was similar between HAH variants and controls; however, the rise in heart rate was blunted in the variants. Our work supports the notion that the hypoxic ventilatory response is regulated by oxygen tension, whereas cardiovascular regulation may be influenced by arterial oxygen content and tension.
Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices
Cross, Troy J. , Sajgalik, Pavol , Fabián, Vratislav , Matera, Lukáš , Kushwaha, Sudhir S. , Maltais, Simon, Stulak, John M., Schirger, John A., Johnson, Bruce D. , Cross, Troy James

The International Journal of Artificial Organs | August 14, 2019 | Volume: 43 | Issue: 2 | Pages: 99-108

10.1177/0391398819868236 Get It

Introduction: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the ‘cuff pulsatility index’. Purpose: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. Methods: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m −2 ) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient’s dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). Results: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. Conclusions: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.
Noninvasive Assessment of Aortic Pulse Wave Velocity by the Brachial Occlusion-Cuff Technique: Comparative Study
Fabián, Vratislav , Matera, Lukáš , Bayerová, Kristýna , Havlík, Jan , Křemen, Václav , Pudil, Jan , Sajgalik, Pavol , Kremen, Vaclav , Zemánek, David

Sensors | August 8, 2019 | Volume: 19 | Issue: 16 | Pages: 3467

10.3390/s19163467 Get It

Cardiovascular diseases are one of most frequent cause of morbidity and mortality in the world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools to assess accurately cardiovascular system primarily in the preventative medicine. We present a novel design for a non-invasive pulse wave velocity (PWV) assessment method integrated in a single brachial blood pressure monitor allowing for up to 100 times more sensitive recording of the pressure pulsations based on a brachial occlusion-cuff (suprasystolic) principle. The monitor prototype with built-in proprietary method was validated with a gold standard reference technique SphygmoCor VX device. The blood pressure and PWV were assessed on twenty-five healthy individuals (9 women, age (37 ± 13) years) in a supine position at rest by a brachial cuff blood pressure monitor prototype, and immediately re-tested using a gold standard method. PWV using our BP monitor was (6.67 ± 0.96) m/s compared to PWV determined by SphygmoCor VX (6.15 ± 1.01) m/s. The correlation between methods using a Pearson’s correlation coefficient was r = 0.88 (p < 0.001). The study demonstrates the feasibility of using a single brachial cuff build-in technique for the assessment of the arterial stiffness from a single ambulatory blood pressure assessment.
Pulmonary Function Assessment Post-Left Ventricular Assist Device Implantation
Sajgalik, Pavol , Kim, Chul‐Ho , Stulak, John M., Kushwaha, Sudhir S. , Maltais, Simon, Joyce, David L. , Joyce, Lyle D., Johnson, Bruce D. , Schirger, John A.

ESC Heart Failure | October 12, 2018 | Volume: 6 | Issue: 1 | Pages: 53-61

10.1002/ehf2.12348 Get It

Abstract Aim The lungs—and particularly the alveolar-capillary membrane—may be sensitive to continuous flow (CF) and pulmonary pressure alterations in heart failure (HF). We aimed to investigate long-term effects of CF pumps on respiratory function. Methods and results We conducted a retrospective study of patients with end-stage HF at our institution. We analysed pulmonary function tests [e.g. forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1)] and diffusing capacity of the lung for carbon monoxide (DLCO) from before and after left ventricular assist device (LVAD) implantation and compared them with invasive haemodynamic studies. Of the 274 patients screened, final study analysis involved 44 patients with end-stage HF who had CF LVAD implantation between 1 February 2007 and 31 December 2015 at our institution. These patients [mean (standard deviation, SD) age, 50 (9) years; male sex, n = 33, 75%] received either the HeartMate II (Thoratec Corp.) pump (77%) or the HeartWare (HeartWare International Inc.) pump. The mean (SD) left ventricular ejection fraction was 21% (13%). At a median of 237 days post-LVAD implantation, we observed significant DLCO decrease (−23%) since pre-implantation (P &lt; 0.001). ΔDLCO had an inverse relationship with changes in pulmonary capillary wedge pressure (PCWP) and right atrial pressure (RAP) from pre-LVAD to post-LVAD implantation: ΔDLCO to ΔPCWP (r = 0.50, P &lt; 0.01) and ΔDLCO to ΔRAP (r = 0.39, P &lt; 0.05). We observed other reductions in FEV1, FVC, and FEV1/FVC between pre-LVAD and post-LVAD implantation. In mean (SD) values, FEV1 changed from 2.3 (0.7) to 2.1 (0.7) (P = 0.005); FVC decreased from 3.2 (0.8) to 2.9 (0.9) (P = 0.01); and FEV1/FVC went from 0.72 (0.1) to 0.72 (0.1) (P = 0.50). Landmark survival analysis revealed that ΔDLCO from 6 months after LVAD implantation was predictive of death for HF patients [hazard ratio (95% confidence interval), 0.60 (0.28–0.98); P = 0.03]. Conclusions Pulmonary function did not improve after LVAD implantation. The degree of DLCO deterioration is related to haemodynamic status post-LVAD implantation. The ΔDLCO within 6 months post-operative was associated with survival.
Noninvasive Blood Pressure Monitor Designed for Patients With Heart Failure Supported with Continuous-Flow Left Ventricular Assist Devices
Sajgalik, Pavol , Křemen, Václav , Fabián, Vratislav , Maltais, Simon, Stulak, John M., Kushwaha, Sudhir S. , Joyce, Lyle D., Schirger, John A., Johnson, Bruce D. , Kremen, Vaclav

ASAIO Journal | March 14, 2018 | Volume: 65 | Issue: 2 | Pages: 127-133

10.1097/mat.0000000000000775 Get It

The gold standard for noninvasive blood pressure (BP) measurement, the Doppler technique, does not provide systolic blood pressure (SBP) and diastolic blood pressure (DBP) and may limit therapy outcomes. To improve patient care, we tested specifically designed experimental BP (ExpBP) monitor and the Doppler technique by comparing noninvasive measures to the intraarterial (I-A) BP in 31 patients with end-stage heart failure (4 females) 2.6 ± 3.4 days post-LVAD implantation (20 HeartMate II and 11 HeartWare). Bland–Altman plots revealed that the ExpBP monitor overestimated mean arterial pressure (MAP) by 1.2 (4.8) mm Hg (mean difference [standard deviation]), whereas the Doppler by 6.7 (5.8) mm Hg. The ExpBP SBP was overestimated by 0.8 (6.1) mm Hg and DBP by 1.9 (5.3) mm Hg compared with the respective I-A pressures. Both techniques achieved similar measurement reliability. In the measurement “success rate” expressed as a frequency (percent) of readable BP values per measurement attempts, Doppler accomplished 100% vs. 97%, 97%, and 94% of successful detections of MAP, SBP, and DBP provided by the ExpBP monitor. The ExpBP monitor demonstrated higher accuracy in the MAP assessment than the Doppler in addition to providing SBP and DBP in majority of subjects. Improved BP control may help to mitigate related neurologic adverse event rates.
Noninvasive assessment of cardiac output by brachial occlusion-cuff technique: comparison with the open-circuit acetylene washin method
Sajgalik, Pavol , Křemen, Václav , Carlson, Alex R. , Fabián, Vratislav , Kim, Chul‐Ho , Wheatley, Courtney M. , Gerla, Václav , Schirger, John A., Olson, Thomas P. , Johnson, Bruce D. , Wheatley, Courtney, Kremen, Vaclav , Gerla, Vaclav

Journal of Applied Physiology | October 21, 2016 | Volume: 121 | Issue: 6 | Pages: 1319-1325

10.1152/japplphysiol.00981.2015 Get It

Cardiac output (CO) assessment as a basic hemodynamic parameter has been of interest in exercise physiology, cardiology, and anesthesiology. Noninvasive techniques available are technically challenging, and thus difficult to use outside of a clinical or laboratory setting. We propose a novel method of noninvasive CO assessment using a single, upper-arm cuff. The method uses the arterial pressure pulse wave signal acquired from the brachial artery during 20-s intervals of suprasystolic occlusion. This method was evaluated in a cohort of 12 healthy individuals (age, 27.7 ± 5.4 yr, 50% men) and compared with an established method for noninvasive CO assessment, the open-circuit acetylene method (OpCirc) at rest, and during low- to moderate-intensity exercise. CO increased from rest to exercise (rest, 7.4 ± 0.8 vs. 7.2 ± 0.8; low, 9.8 ± 1.8 vs. 9.9 ± 2.0; moderate, 14.1 ± 2.8 vs. 14.8 ± 3.2 l/min) as assessed by the cuff-occlusion and OpCirc techniques, respectively. The average error of experimental technique compared with OpCirc was −0.25 ± 1.02 l/min, Pearson’s correlation coefficient of 0.96 (rest + exercise), and 0.21 ± 0.42 l/min with Pearson’s correlation coefficient of 0.87 (rest only). Bland-Altman analysis demonstrated good agreement between methods (within 95% boundaries); the reproducibility coefficient (RPC) = 0.84 l/min with R2= 0.75 at rest and RPC = 2 l/min with R2= 0.92 at rest and during exercise, respectively. In comparison with an established method to quantify CO, the cuff-occlusion method provides similar measures at rest and with light to moderate exercise. Thus, we believe this method has the potential to be used as a new, noninvasive method for assessing CO during exercise.