Aerosol Generation During Spirometry and Simulated Bronchodilator Challenge Testing in the Pulmonary Function Laboratory
Gmehlin, Cameron G., Sajgalik, Pavol , Hainy, Matthew E, Kim, Chul‐Ho , Johnson, Bruce D. , Allison, Thomas G. , Gmehlin, Cameron G. , Lim, Kaiser, Lim, Kaiser G. , Niven, Alexander S.

Respiratory Care | February 3, 2025 | Volume: 70 | Issue: 4 | Pages: 446-449

10.1089/respcare.12506 Get It

Aerosol Generation Using Different Delivery Methods During Simulated Bronchodilator Challenge Testing in the Pulmonary Function Laboratory
Gmehlin, C.G., Sajgalik, Pavol , Hainy, M., Chul-Ho, K., Johnson, Bruce D. , Allison, Thomas G. , Chul-Ho, K., Lim, Kaiser G. , Niven, Alexander S.

A75. REVISITING CURRENT METHODS IN PULMONARY FUNCTION TESTING | April 30, 2024 | Volume: No volume available | Issue: No issue available | Pages: A2626-A2626

10.1164/ajrccm-conference.2024.209.1_meetingabstracts.a2626 Get It

Abstract 19659: Long Term Left Ventricular Assist Device Therapy: Renal Response to Pulsatile vs Continuous Flow
Sajgalik, Pavol , J, Park Soon, Edwards, Brooks S., Kuswaha, Sudrih, Daly, Richard C. , Joyce, Lyle D., Nemec, Peter, Kára, Tomáš, Brunett, John C, Boilson, Barry A. , Chen, Horng H. , Schirger, John A.

Circulation | April 23, 2024 | Volume: 126 | Issue: suppl_21 | Pages: No page available

10.1161/circ.126.suppl_21.a19659 Get It

Background: Left ventricle assist device (LVAD) support, a well established therapy in advanced CHF, improves renal function assessed by creatinine. While renal function in large numbers of continuous flow (CF) LVADs vs pulsatile flow (PF) LVADs has been evaluated at 3 mo., long term studies are needed with large numbers of CF vs PF devices. To date longer term analysis comparing renal function in CF vs PF devices have relied on a small number of CF devices. We evaluated renal function assessed by creatinine in a large number of CF (HM II) (n=119) devices and compared this to renal function in a group of subjects treated with PF devices (HM XVE) (n=8) at 6 mo. post implant. Our aim was to evaluate change in creatinine between 3 and 6 months in these groups. Methods and Results: Plasma creatinine was evaluated at 3 and 6 months in two groups: subjects with CF HM II (n=119) and PF LVAD (HM XVE, n=8). The data were collected from two centers in patients undergoing implant for destination or bridge to transplant therapy. Baseline creatinine was higher in the HM XVE group at baseline (BL), and decreased at 3 mo. (1.7 [1.1-2.1] vs 1.1 [0.8-1.5] mg/dL, p<0.05). BL creatine in the HM II group decreased at 3 mo as well (1.2 [1-1.5] vs 1.1 [0.9-1.3] mg/dL, p,0.05). Between 3 and 6 months there was no difference in degree of creatinine change in CF vs PF, however both groups had an increase in Creatinine in this time frame: PF (1.1 [0.8-1.5] vs 1.35 [1.05-1.9] mg/dL, p<0.05); CF (1.1 [0.9-1.3] vs 1.2 [0.92-1.4] mg/dL, p<0.05). Conclusion: This is the first study to demonstrate with large numbers of CF LVAD that creatinine does not incrementally increase between 3 and 6 mo. in comparison to PF LVAD. Further studies are required with large numbers of continuos flow LVADs evaluating the comparative effect of long term continuous flow vs pulsatile flow. Additionally, it remains important to identify surrogates of pulsatility in subjects with continuous flow devices and evaluate prognostic impact on renal function long term.
Feasibility of Brachial Occlusion Technique for Beat-to-Beat Pulse Wave Analysis
Matera, Lukáš , Sajgalik, Pavol , Fabián, Vratislav , Mikhailov, Yegor, Johnson, Bruce D. , Zemánek, David

Sensors | September 28, 2022 | Volume: 22 | Issue: 19 | Pages: 7285

10.3390/s22197285 Get It

Czech physiologist Penaz tried to overcome limitations of invasive pulse-contour methods (PCM) in clinical applications by a non-invasive method (finger mounted BP cuff) for continuous arterial waveform detection and beat-to-beat analysis. This discovery resulted in significant interest in human physiology and non-invasive examination of hemodynamic parameters, however has limitations because of the distal BP recording using a volume-clamp method. Thus, we propose a validation of beat-to-beat signal analysis acquired by novel a brachial occlusion-cuff (suprasystolic) principle and signal obtained from Finapres during a forced expiratory effort against an obstructed airway (Valsalva maneuver). Twelve healthy adult subjects [2 females, age = (27.2 ± 5.1) years] were in the upright siting position, breathe through the mouthpiece (simultaneously acquisition by brachial blood pressure monitor and Finapres) and at a defined time were asked to generate positive mouth pressure for 20 s (Valsalva). For the purpose of signal analysis, we proposed parameter a “Occlusion Cuff Index” (OCCI). The assumption about similarities between measured signals (suprasystolic brachial pulse waves amplitudes and Finapres’s MAP) were proved by averaged Pearson’s correlation coefficient (r- = 0.60, p < 0.001). The averaged Pearson’s correlation coefficient for the comparative analysis of OCCI between methods was r- = 0.88, p < 0.001. The average percent change of OCCI during maneuver: 8% increase, 19% decrease and percent change of max/min ratio is 35%. The investigation of brachial pulse waves measured by novel brachial blood pressure monitor shows positive correlation with Finapres and the parameter OCCI shows promise as an index, which could describe changes during beat-to-beat cardiac cycles.
Aerosol Generation and Mitigation During Methacholine Bronchoprovocation Testing: Infection Control Implications in the Era of COVID-19
Subat, Yosuf W., Hainy, Matthew E, Torgerud, Keith D, Sajgalik, Pavol , Guntupalli, Siva Kamal, Johnson, Bruce D. , Kim, Chul‐Ho , Scanlon, Paul D., Chul-Ho, Kim, Lim, Kaiser G. , Helgeson, Scott A. , Niven, Alexander S.

Respiratory Care | November 17, 2021 | Volume: 66 | Issue: 12 | Pages: 1858-1865

10.4187/respcare.09236 Get It

BACKGROUND: Methacholine bronchoprovocation or challenge testing (MCT) is commonly performed to assess airway hyper-responsiveness in the setting of suspected asthma. Nebulization is an aerosol-generating procedure, but little is known about the risks of MCT in the context of the ongoing coronavirus disease 2019 (COVID-19) pandemic. We aimed to quantify and characterize aerosol generation during MCT by using different delivery methods and to assess the impact of adding a viral filter. METHODS: Seven healthy subjects performed simulated MCT in a near particle-free laboratory space with 4 different nebulizers and with a dosimeter. Two devices continuously sampled the ambient air during the procedure, which detected ultrafine particles, from 0.02–1 μm, and particles of sizes 0.3, 0.5, 1.0, 2.0, 5.0, and 10 µm, respectively. Particle generation was compared among all the devices, with and without viral filter placement. RESULTS: Ultrafine-particle generation during simulated MCT was significant across all the devices. Ultrafine-particle (0.02–1 μm) concentrations decreased 77%–91% with the addition of a viral filter and varied significantly between unfiltered (P < .001) and filtered devices (P < .001). Ultrafine-particle generation was lowest when using the dosimeter with filtered Hudson nebulizer (1,258 ± 1,644 particle/mL). Ultrafine-particle concentrations with the filtered nebulizer devices using a compressor were higher than particle concentrations detected when using the dosimeter: Monaghan (3,472 ± 1,794 particles/mL), PARI (4,403 ± 2,948), Hudson (6,320 ± 1,787) and AirLife (9,523 ± 5,098). CONCLUSIONS: The high particle concentrations generated during MCT pose significant infection control concerns during the COVID-19 pandemic. Particle generation during MCT was significantly reduced by using breath-actuated delivery and a viral filter, which offers an effective mitigation strategy.
Aerosol Generation During Peak Flow Testing: Clinical Implications for COVID-19
Subat, Yosuf W., Guntupalli, Siva Kamal, Sajgalik, Pavol , Hainy, Matthew E, Torgerud, Keith D, Johnson, Bruce D. , Allison, Thomas G. , Helgeson, Scott A. , Lim, Kaiser G. , Niven, Alexander S.

Respiratory Care | May 25, 2021 | Volume: 66 | Issue: 8 | Pages: 1291-1298

10.4187/respcare.08731 Get It

BACKGROUND: Peak flow testing is a common procedure performed in ambulatory care. There are currently no data regarding aerosol generation during this procedure. Given the ongoing debate regarding the potential for aerosol transmission of SARS-CoV-2, we aimed to quantify and characterize aerosol generation during peak flow testing. METHODS: Five healthy volunteers performed peak flow maneuvers in a particle-free laboratory space. Two devices continuously sampled the ambient air during the procedure. One device can detect ultrafine particles 0.02–1 μ m in diameter, while the second device can detect particles 0.3, 0.5, 1.0, 2.0, 5.0, and 10 μ m in diameter. Five different peak flow meters were compared to ambient baseline during masked and unmasked tidal breathing. RESULTS: Ultrafine particles (0.02–1 μ m) were generated during peak flow measurement. There was no significant difference in ultrafine particle mean concentration between peak flow meters ( P = .23): Respironics (1.25 ± 0.47 particles/mL), Philips (3.06 ± 1.22), Clement Clarke (3.55 ± 1.22 particles/mL), Respironics Low Range (3.50 ± 1.52 particles/mL), and Monaghan (3.78 ± 1.31 particles/mL). Ultrafine particle mean concentration with peak flow testing was significantly higher than masked (0.22 ± 0.29 particles/mL) and unmasked tidal breathing (0.15 ± 0.18 particles/mL, P = .01), but the ultrafine particle concentrations were small compared to ambient particle concentrations in a pulmonary function testing room (89.9 ± 8.95 particles/mL). CONCLUSIONS: In this study, aerosol generation was present during peak flow testing, but concentrations were small compared to the background particle concentration in the ambient clinical environment. Surgical masks and eye protection are likely sufficient infection control measures during peak expiratory flow testing in asymptomatic patients with well controlled respiratory symptoms, but COVID-19 testing remains prudent in patients with acute respiratory symptoms prior to evaluation and peak expiratory flow assessment while the community prevalence of SARS-CoV-2 cases remains high.
Aerosol Generation During Peak Flow Testing: Clinical Implications During the COVID-19 Pandemic
Subat, Yosuf W., Guntupalli, Siva Kamal, Sajgalik, Pavol , Hainy, M., Johnson, Bridgette, Helgeson, Scott A. , Niven, Alexander S.

TP117. TP117 COVID-19 PATHOPHYSIOLOGY AND MODELLING | May 4, 2021 | Volume: No volume available | Issue: No issue available | Pages: A4474-A4474

10.1164/ajrccm-conference.2021.203.1_meetingabstracts.a4474 Get It

Aerosol Generation During Methacholine Challenge Testing: Clinical Implications During the COVID-19 Pandemic
Subat, Yosuf W., Sajgalik, Pavol , Hainy, M., Torgerud, Keith D, Guntupalli, Siva Kamal, Scanlon, Paul D., Johnson, Bridgette, Helgeson, Scott A. , Johnston, J., Niven, Alexander S.

TP117. TP117 COVID-19 PATHOPHYSIOLOGY AND MODELLING | May 4, 2021 | Volume: No volume available | Issue: No issue available | Pages: A4473-A4473

10.1164/ajrccm-conference.2021.203.1_meetingabstracts.a4473 Get It

Exercise as a Therapeutic Strategy for Sarcopenia in Heart Failure: Insights into Underlying Mechanisms
Cho, Jinkyung , Choi, Youngju , Sajgalik, Pavol , No, Mi‐Hyun , Lee, Sang-Hyun , Kim, Sujin , Heo, Jun‐Won , Cho, Eun‐Jeong , Chang, Eunwook , Kang, Ju‐Hee , Kwak, Hyo‐Bum , Park, Dong‐Ho , Schaefer, Jacob J

Cells | October 15, 2020 | Volume: 9 | Issue: 10 | Pages: 2284

10.3390/cells9102284 Get It

Sarcopenia, a syndrome commonly seen in elderly populations, is often characterized by a gradual loss of skeletal muscle, leading to the decline of muscle strength and physical performance. Growing evidence suggests that the prevalence of sarcopenia increases in patients with heart failure (HF), which is a dominant pathogenesis in the aging heart. HF causes diverse metabolic complications that may result in sarcopenia. Therefore, sarcopenia may act as a strong predictor of frailty, disability, and mortality associated with HF. Currently, standard treatments for slowing muscle loss in patients with HF are not available. Therefore, here, we review the pathophysiological mechanisms underlying sarcopenia in HF as well as current knowledge regarding the beneficial effects of exercise on sarcopenia in HF and related mechanisms, including hormonal changes, myostatin, oxidative stress, inflammation, apoptosis, autophagy, the ubiquitin-proteasome system, and insulin resistance.
Is Low Resistance Exercise in Left Ventricular Assisted Device (LVAD) Patients Associated with Airway Obstruction?
Patel, Neel , Sajgalik, Pavol , Johnson, D. F., Patel, N.

D78. CO-MORBIDITIES, CANCER, INFECTION, SEPSIS | July 7, 2020 | Volume: No volume available | Issue: No issue available | Pages: A7614-A7614

10.1164/ajrccm-conference.2020.201.1_meetingabstracts.a7614 Get It