Clinical Medicine Insights: Circulatory, Respiratory and Pulmonary Medicine | July 25, 2018 | Volume: 12 | Issue: No issue available | Pages: No page available
Cardiac hemodynamic assessment during cardiopulmonary exercise testing (CPET) is proposed to play an important role in the clinical evaluation of individuals with cystic fibrosis (CF). Cardiac catheterization is not practical for routine clinical CPET. Use of oxygen pulse (O 2 pulse) as a noninvasive estimate of stroke volume (SV) has not been validated in CF. This study tested the hypothesis that peak exercise O 2 pulse is a valid estimate of SV in CF. Measurements of SV via the acetylene rebreathe technique were acquired at baseline and peak exercise in 17 mild-to-moderate severity adult CF and 25 age-matched healthy adults. We calculated [Formula: see text]. Baseline relationships between SV and O 2 pulse were significant in CF ( r = .80) and controls ( r = .40), persisting to peak exercise in CF ( r = .63) and controls ( r = .73). The standard error of estimate for O 2 pulse-predicted SV with respect to measured SV was similar at baseline (14.1 vs 20.1 mL) and peak exercise (18.2 vs 13.9 mL) for CF and controls, respectively. These data suggest that peak exercise O 2 pulse is a valid estimate of SV in CF. The ability to noninvasively estimate SV via O 2 pulse during routine clinical CPET can be used to improve test interpretation and advance our understanding of the impact cardiac dysfunction has on exercise intolerance in CF.
Streamlining cardiopulmonary exercise testing for use as a screening and tracking tool in primary care
Cardiopulmonary exercise testing (CPET) using a spectrum of different approaches demonstrates usefulness for objectively assessing patient disease severity in clinical and research settings. Still, an absence of trained specialists and/or improper data interpretation techniques can pose major limitations to the effective use of CPET for the clinical classification of patients. This study aimed to test an automated disease likelihood scoring algorithm system based on cardiopulmonary responses during a simplified step‐test protocol. For patients with heart failure (HF), pulmonary hypertension (PAH), obstructive lung disease (OLD), or restrictive lung disease (RLD), we compared patient scores stratified into one of four “silos” generated from our novel algorithm system against patient evaluations provided by expert clinicians. Patients with HF (n = 12), PAH (n = 9), OLD (n = 16), or RLD (n = 10) performed baseline pulmonary function testing followed by submaximal step‐testing. Breath‐by‐breath measures of ventilation and gas exchange, in addition to oxygen saturation and heart rate were collected continuously throughout testing. The algorithm demonstrated close alignment with patient assessments provided by clinical specialists: HF (r = 0.89, P < 0.01); PAH (r = 0.88, P < 0.01); OLD (r = 0.70, P < 0.01); and RLD (r = 0.88, P < 0.01). Furthermore, the algorithm was capable of differentiating major disease from other disease pathologies. Thus, in a clinically relevant manner, these data suggest this simplified automated disease algorithm scoring system used during step‐testing to identify the likelihood that patients have HF, PAH, OLD, or RLD closely correlates with patient assessments conducted by trained clinicians.
Resistive and elastic work of breathing in older and younger adults during exercise
It is unknown whether the greater total work of breathing (WOB) with aging is due to greater elastic and/or resistive WOB. We hypothesized that older compared with younger adults would exhibit a greater total WOB at matched ventilations (V̇e) during graded exercise, secondary to greater inspiratory resistive and elastic as well as expiratory resistive WOB. Older (OA: 60 ± 8 yr; n = 9) and younger (YA: 38 ± 7 yr; n = 9) adults performed an incremental cycling test to volitional fatigue. Esophageal pressure, inspiratory (IRV) and expiratory reserve volumes (ERV), expiratory flow limitation (EFL), and ventilatory variables were measured at matched V̇e (i.e., 25, 50, and 75 l/min) during exercise. The inspiratory resistive and elastic as well as expiratory resistive WOB were quantified using the Otis method. At V̇e of 75 l/min, older adults had greater %EFL and larger tidal volumes to inspiratory capacity but smaller relative IRV ( P ≤ 0.03) than younger adults. Older compared with younger adults had greater total WOB at V̇Eof 50 and 75 l/min (OA: 90 ± 43 vs. YA: 49 ± 21 J/min; P < 0.04 for both). At V̇e of 75 l/min, older adults had greater inspiratory elastic and resistive WOB (OA: 44 ± 27 vs. YA: 24 ± 22 and OA: 23 ± 15 vs. YA: 11 ± 3 J/min, respectively, P < 0.03 for both) and expiratory resistive WOB (OA: 23 ± 19 vs. YA: 14 ± 9 J/min, P = 0.02) than younger adults. These data demonstrate that aging-induced pulmonary alterations result in greater inspiratory elastic and resistive as well as expiratory resistive WOB, which may have implications for the integrated response during exercise.NEW & NOTEWORTHY Aging-induced changes to the pulmonary system result in increased work of breathing (WOB) during exercise. However, it is not known whether this higher WOB with aging is due to differences in elastic and/or resistive WOB. Herein, we demonstrate that older adults exhibited greater inspiratory elastic and resistive as well as expiratory resistive WOB during exercise.
Exercise on‐transition uncoupling of ventilatory, gas exchange and cardiac hemodynamic kinetics accompany pulmonary oxygen stores depletion to impact exercise intolerance in human heart failure
AbstractAimIn contrast to knowledge that heart failure (HF) patients demonstrate peak exercise uncoupling across ventilation, gas exchange and cardiac haemodynamics, whether this dyssynchrony follows that at the exercise on‐transition is unclear. This study tested whether exercise on‐transition temporal lag for ventilation relative to gas exchange and oxygen pulse (O2pulse) couples with effects from abnormal pulmonary gaseous oxygen store (O2store) contributions to O2 to interdependently precipitate persistently elevated ventilatory demand and low oxidative metabolic capacity in HF.MethodsBeat‐to‐beat HR and breath‐to‐breath ventilation and gas exchange were continuously acquired in HF (N = 9, ejection fraction = 30 ± 9%) and matched controls (N = 10) during square‐wave ergometry at 60% O2peak (46 ± 14 vs 125 ± 54‐W, P < .001). Temporal responses across E, O2 and O2pulse were assessed for the exercise on‐transition using single exponential model Phase II on‐kinetic time constants (τ = time to reach 63% steady‐state rise). Breath‐to‐breath gas fractions and respiratory flows were used to determine O2stores.ResultsHF vs controls: τ for E (137 ± 93 vs 74 ± 40‐seconds, P = .03), O2 (60 ± 40 vs 23 ± 5‐seconds, P = .03) and O2pulse (28 ± 18 vs 23 ± 15‐seconds, P = .59). Within HF, τ for E differed from O2pulse (P < .02), but not O2. Exercise E rise (workload indexed) differed in HF vs controls (545 ± 139 vs 309 ± 88‐mL min−1 W−1, P < .001). Exercise on‐transition O2store depletion in HF exceeded controls, generally persisting to end‐exercise.ConclusionThese data suggest HF demonstrated exercise on‐transition O2store depletion (high O2store contribution to O2) coupled with dyssynchronous E, O2 and O2pulse kinetics—not attributable to prolonged cardiac haemodynamics. Persistent high ventilatory demand and low oxidative metabolic capacity in HF may be precipitated by physiological uncoupling occurring within the exercise on‐transition.
Alveolar air and oxidative metabolic demand during exercise in healthy adults: the role of single-nucleotide polymorphisms of the β
2
AR gene
Physiological Dead Space and Arterial Carbon Dioxide Contributions to Exercise Ventilatory Inefficiency in Patients with Reduced or Preserved Ejection Fraction Heart Failure
Abstract Aims Patients with heart failure (HF) with reduced (HFrEF) or preserved (HFpEF) ejection fraction demonstrate an increased ventilatory equivalent for carbon dioxide (V̇E/V̇CO2) slope. The physiological correlates of the V̇E/V̇CO2 slope remain unclear in the two HF phenotypes. We hypothesized that changes in the physiological dead space to tidal volume ratio (VD/VT) and arterial CO2 tension (PaCO2) differentially contribute to the V̇E/V̇CO2 slope in HFrEF vs. HFpEF. Methods and results Adults with HFrEF (n = 32) and HFpEF (n = 27) [mean ± standard deviation (SD) left ventricular ejection fraction: 22 ± 7% and 61 ± 9%, respectively; mean ± SD body mass index: 28 ± 4 kg/m2 and 33 ± 6 kg/m2, respectively; P < 0.01] performed cardiopulmonary exercise testing with breath-by-breath ventilation and gas exchange measurements. PaCO2 was measured via radial arterial catheterization. We calculated the V̇E/V̇CO2 slope via linear regression, and VD/VT = 1 − [(863 × V̇CO2)/(V̇E × PaCO2)]. Resting VD/VT (0.48 ± 0.08 vs. 0.41 ± 0.11; P = 0.04), but not PaCO2 (38 ± 5 mmHg vs. 40 ± 3 mmHg; P = 0.21) differed between HFrEF and HFpEF. Peak exercise VD/VT (0.39 ± 0.08 vs. 0.32 ± 0.12; P = 0.02) and PaCO2 (33 ± 6 mmHg vs. 38 ± 4 mmHg; P < 0.01) differed between HFrEF and HFpEF. The V̇E/V̇CO2 slope was higher in HFrEF compared with HFpEF (44 ± 11 vs. 35 ± 8; P < 0.01). Variance associated with the V̇E/V̇CO2 slope in HFrEF and HFpEF was explained by peak exercise VD/VT (R2 = 0.30 and R2 = 0.50, respectively) and PaCO2 (R2 = 0.64 and R2 = 0.28, respectively), but the relative contributions of each differed (all P < 0.01). Conclusions Relationships between the V̇E/V̇CO2 slope and both VD/VT and PaCO2 are robust, but differ between HFpEF and HFrEF. Increasing V̇E/V̇CO2 slope appears to be strongly explained by mechanisms influential in regulating PaCO2 in HFrEF, which contrasts with the strong role of increased VD/VT in HFpEF.
V̇o2 kinetics associated with moderate-intensity exercise in heart failure: impact of intrathecal fentanyl inhibition of group III/IV locomotor muscle afferents
Heart failure (HF) patients demonstrate impaired pulmonary, circulatory, and nervous system responses to exercise. While HF demonstrates prolonged [time constant (τ)] pulmonary O2 uptake (V̇o2) on-kinetics, contributing to exercise intolerance, it is unknown whether abnormal V̇o2 kinetics couple with ventilatory and circulatory dysfunction secondary to impaired group III/IV afferents in HF. Because lower lumbar intrathecal fentanyl inhibits locomotor muscle afferents, resulting in improved exercise ventilation and hemodynamics, we tested these hypotheses: HF will demonstrate 1) rapid V̇o2 on-kinetics and 2) attenuated steady-state V̇o2 amplitude and O2 deficit (O2def) during exercise with fentanyl versus placebo. On separate visits (randomized), breath-by-breath V̇o2 was measured in HF (ejection fraction: 27 ± 6%, New York Heart Association class I–III) and age- and sex-matched controls (both n = 9, ages: 60 ± 6 vs. 63 ± 8 yr, P = 0.37) during cycling transitions at 65% peak workload (78 ± 24 vs. 115 ± 39 W, P < 0.01) with intrathecal fentanyl or placebo. Regardless of group or condition, optimal phase II (primary component) curve fits reflected a phase I period equal to 35 s (limb-to-lung timing) via single-exponential functions. Condition did not affect steady-state V̇o2, the phase II τ of V̇o2, or O2def within controls ( P > 0.05). Without differences in steady-state V̇o2, reduced O2def in fentanyl versus placebo within HF (13 ± 4 vs. 22 ± 15 ml/W, P = 0.04) was accounted for by a rapid phase II τ of V̇o2 in fentanyl versus placebo within HF (45 ± 11 vs. 57 ± 14 s, P = 0.04), respectively. In an integrative manner, these data demonstrate important effects of abnormal locomotor muscle afferents coupled to pulmonary and circulatory dysfunction in determining impaired exercise V̇o2 in HF. Effects of abnormal muscle afferents on impaired exercise V̇o2 and hence exercise intolerance may not be discernable by independently assessing steady-state V̇o2 in HF. NEW & NOTEWORTHY Inhibition of locomotor muscle afferents results in rapid primary-component O2 uptake (V̇o2) on-kinetics accounting for the decreased O2 deficit in heart failure (HF). This study revealed that abnormal musculoskeletal–neural afferents couple with pulmonary and circulatory dysfunction to provoke impaired exercise V̇o2 in HF. Steady-state V̇o2 cannot properly phenotype abnormal muscle afferent contributions to impaired exercise V̇o2 in HF.
The Influence of 17 Hours of Normobaric Hypoxia on Parallel Adjustments in Exhaled Nitric Oxide and Airway Function in Lowland Healthy Adults
Although pathophysiological links between postmenopause and healthy aging remain unclear, both factors are associated with increased blood pressure and sympathetic nerve activity (SNA) in women. Activation of polymodal musculoskeletal neural afferents originating within adventia of venules modulates SNA and blood pressure control during exercise in healthy adults. We hypothesized transient subsystolic regional circulatory occlusion (RCO) during exercise sensitizes these afferents leading to augmented systemic vascular resistance (SVR)-mediated increased mean arterial pressure (MAP) in postmenopause vs. premenopause. Normotensive women in premenopause or postmenopause ( n = 14 and 14; ages: 30 ± 9 and 55 ± 7 yr, respectively; P < 0.01) performed: 1) peak exercise testing and 2) fixed-load cycling at 30% peak workload (48 ± 11 and 38 ± 6 W, respectively; P < 0.01), whereby the initial 3 min were control exercise without RCO (CTL), thereafter including 2 min of bilateral-thigh RCO to 20, 40, 60, 80, or 100 mmHg (randomized), with 2 min deflation between RCO. Both MAP (17 ± 4 vs. 4 ± 4%, P = 0.02) and SVR (16 ± 8 vs. −3 ± 8%, P = 0.04) increased at 80 mmHg from CTL in postmenopause vs. premenopause, respectively. However, cardiac index was similar in postmenopause vs. premenopause at 80 mmHg from CTL (1 ± 6 vs. 7 ± 6%, respectively; P = 0.15). There was no continuous effect of aging in MAP ( P = 0.12), SVR ( P = 0.07), or cardiac index ( P = 0.18) models. These data suggest transient locomotor subsystolic RCO sensitizes musculoskeletal afferents, which provoke increased SVR to generate augmented MAP during exercise in postmenopause. These observations provide a novel approach for understanding the age-independent variability in exercise blood pressure control across the normotensive adult pre- to postmenopause spectrum.
Reliability of Triaxial Accelerometry for Measuring Load in Men's Collegiate Ice Hockey
Abstract Van Iterson, EH, Fitzgerald, JS, Dietz, CC, Snyder, EM, and Peterson, BJ. Reliability of triaxial accelerometry for measuring load in men's collegiate ice hockey. J Strength Cond Res 31(5): 1305–1312, 2017—Wearable microsensor technology incorporating triaxial accelerometry is used to quantify an index of mechanical stress associated with sport-specific movements termed PlayerLoad. The test-retest reliability of PlayerLoad in the environmental setting of ice hockey is unknown. The primary aim of this study was to quantify the test-retest reliability of PlayerLoad in ice hockey players during performance of tasks simulating game conditions. Division I collegiate male ice hockey players ( N = 8) wore Catapult Optimeye S5 monitors during repeat performance of 9 ice hockey tasks simulating game conditions. Ordered ice hockey tasks during repeated bouts included acceleration (forward or backward), 60% top-speed, top-speed (forward or backward), repeated shift circuit, ice coasting, slap shot, and bench sitting. Coefficient of variation (CV), intraclass correlation coefficient (ICC), and minimum difference (MD) were used to assess PlayerLoad reliability. Test-retest CVs and ICCs of PlayerLoad were as follows: 8.6% and 0.54 for forward acceleration, 13.8% and 0.78 for backward acceleration, 2.2% and 0.96 for 60% top-speed, 7.5% and 0.79 for forward top-speed, 2.8% and 0.96 for backward top-speed, 26.6% and 0.95 for repeated shift test, 3.9% and 0.68 for slap shot, 3.7% and 0.98 for coasting, and 4.1% and 0.98 for bench sitting, respectively. Raw differences between bouts were not significant for ice hockey tasks ( p > 0.05). For each task, between-bout raw differences were lower vs. MD: 0.06 vs. 0.35 (forward acceleration), 0.07 vs. 0.36 (backward acceleration), 0.00 vs. 0.06 (60% top-speed), 0.03 vs. 0.20 (forward top-speed), 0.02 vs. 0.09 (backward top-speed), 0.18 vs. 0.64 (repeated shift test), 0.02 vs. 0.10 (slap shot), 0.00 vs. 0.10 (coasting), and 0.01 vs. 0.11 (bench sitting), respectively. These data suggest that PlayerLoad demonstrates moderate-to-large test-retest reliability in the environmental setting of male Division I collegiate ice hockey. Without previously testing reliability, these data are important as PlayerLoad is routinely quantified in male collegiate ice hockey to assess on ice physical activity.