ABSTRACT Introduction Literature concerning corporotomy location in multi-component inflatable penile prosthetic surgery via a penoscrotal approach is scarce if not non-existent. However, corporotomy location represents an important issue that may influence immediate and long-term outcomes regarding patient and partner satisfaction as well as device durability. Objective To report practices in low- and high-volume penile implant centers regarding corporotomy location. Methods Data from 18 (13 European and 5 American) implant centers were collected retrospectively between September 1st, 2018 and August 31st, 2019. Variables included: intraoperative proximal and distal corpus cavernosum length measurement, total corporal length measurement, total penile implant cylinder length, and length of rear tip extenders. Additionally, patient characteristics, indication for penile implant, operative time, type of implant utilized, reservoir characteristics and short term complications were reported. Results 809 virgin penile implant cases were included in the analysis. Mean age of participants was 61.5 +/- 9.6 years old. In total, 299 AMS 700TM (Boston Scientific) and 510 Coloplast Titan® devices were implanted. The mean proximal/distal corporal measurement ratio during corporotomy was 0.93 +/- 0.29. A statistically significant correlation between lower proximal /distal measurement ratio and higher age (p=0.0013), lower BMI (p<0.0001), use of rear tip extenders (RTE) (p=0.04), lower RTE length (p<0.0001) and absence of diabetes (p=0.0004) was reported. In a 3-month follow up period 49 complications and 37 revision procedures were reported. Conclusions This is the first study reporting and evaluating the current practices regarding corporotomy location during IPP placement in a multicenter cohort, particularly when including such a high number of patients. Nevertheless, the retrospective design limits the study outcomes. Even in experienced hands proximal length measurement in relation to distal length measurement in penoscrotal IPP surgery is in many cases sub-optimal, particularly when the tubing-cylinder connection of each device is taken into account. Disclosure No
Impact of Antimicrobial Dipping Solutions on Postoperative Infection Rates in Patients with Diabetes Undergoing Primary Insertion of a Coloplast Titan Inflatable Penile Prosthesis
Abstract Background Modern-day penile prostheses use infection retardant coating to decrease rates of postoperative infection, subsequently reducing explantation and revision rates as well. The Coloplast Titan models are dipped into antimicrobial solutions right before implantation, and the components used for dipping can be tailored toward the patient. Aim To compare infection, explantation, and revision rates among different dipping solutions used before implantation for patients with diabetes receiving a Coloplast Titan implant. Methods We systematically reviewed 932 patients with diabetes receiving a primary penile implant across 18 different centers from the period April 2003 to August 2018. Of those patients, 473 received a Coloplast device, whereas 459 received an AMS device. Data regarding the type of antimicrobial solution used before implantation were recorded for 468 patients receiving a Coloplast Titan, including whether or not they suffered a postoperative infection and if they underwent explantation and/or revision. Outcome rates were compared using Fisher’s exact and Pearson’s chi-square tests, and logistic regression modeling was performed to account for covariates. Outcomes The main outcome measures of this study were postoperative infection, explantation, and revision rates. Results Of the total 932 patients reviewed, 33 suffered a postoperative infection. Of 468 patients receiving Coloplast implants, there was a 3.4% infection rate. The most commonly used antibiotic combination before dipping was vancomycin + gentamicin (59.0%). There was a significantly lower rate of postoperative infection, explantation, and revision when vancomycin + gentamicin was used than those associated with the use of all other dipping solutions ([1.4% vs 6.4%; P = .004], [1.1% vs 8.3%; P < .001], and [2.5% vs 12.5; P < .001], respectively). After adjusting for age, body mass index, preoperative blood glucose level, and hemoglobin A1c, the use of other dips was an independent predictor of postoperative infection (odds ratio: 0.191; P = .049). The inclusion of rifampin in the dipping solution trended toward being a significant risk factor for infection (P = .057). Including antifungals in the dipping solution did not affect infection (P = .414), explantation (P = .421), or revision (P = .328) rates. Clinical Implications Vancomycin + gentamicin was the most efficacious combination of antibiotics used for dipping in terms of preventing postoperative infection and subsequent explantation and revision. Strengths and Limitations Data were sampled across multiple institutions providing a large sample that may be more representative of the population of interest. A key limitation of the study was its retrospective nature, which prevented us from controlling certain variables. Conclusion The use of rifampin did not provide the same type of protection, possibly representing a shift in resistance patterns of common bacteria responsible for device infection.
A Multicenter Investigation Examining American Urological Association Recommended Antibiotic Prophylaxis vs Nonstandard Prophylaxis in Preventing Device Infections in Penile Prosthesis Surgery in Diabetic Patients
Multicenter Experience Using Collagen Fleece for Plaque Incision with Grafting to Correct Residual Curvature at the Time of Inflatable Penile Prosthesis Placement in Patients with Peyronie's Disease
Abstract Background Adjuvant maneuvers are often necessary to correct residual curvature during inflatable penile prosthesis (IPP) placement in patients with Peyronie's disease (PD). Aim We present our multicenter experience using collagen fleece as graft material for plaque incision and grafting (PIG) during IPP placement in patients with moderate to severe PD. Methods We retrospectively reviewed 51 patients with IPP from 3 sites who underwent PIG with Tachosil (Baxter, IL) collagen fleece. Coloplast (Minneapolis, MN) IPP devices were used. Factors associated with residual curvature, revision, and patient satisfaction were performed using chi-squared analysis. Outcomes We evaluated postoperative outcomes including factors associated with residual curvature, revision, and patient satisfaction. Results The mean compound curvature was 69.6°. The mean follow-up was 10.6 (range 1–38) months. All patients reported erections sufficient for penetrative intercourse at the last follow-up. Residual curvature <15° was noted in 6 of 51 (12%) patients. 3 patients required device revision. 2 patients experienced temporary glanular paresthesia, and no patients experienced device infection. Clinical Implications In our multicenter study, patients experienced substantial curve correction with minimal complications, and in the few patients who had persistent mild curvature, severe preoperative curvature (>60°) was found to be the only risk factor. Strengths & Limitations Our study represents the largest series of patients coming from multiple centers undergoing surgical correction of PD with IPP and collagen fleece grafting. Limitations of this study include the retrospective study design, lack of a comparison group, and modest follow-up. Conclusion PIG using collagen fleece is a safe and effective means of correcting residual curvature after IPP placement in patients with moderate to severe PD.
152 Multi-Center Experience Utilizing Collagen Fleece for Plaque Incision with Grafting to Correct Residual Curvature at Time of Inflatable Penile Prosthesis Placement in Peyronie's Disease Patients
105 Impact of Antimicrobial Dipping Solutions on Post-Operative Infection Rates in Diabetic Patients Undergoing Primary Insertion of a Coloplast Titan Inflatable Penile Prosthesis
106 Immediate Preoperative Blood Glucose and Hemoglobin A1c Levels are not Predictive of Post-Operative Infections in Diabetic Men Undergoing Penile Prosthesis Placement
028 Adherence to the AUA Penile Prosthesis Antibiotic Prophylaxis Guidelines in Diabetic Patients is Associated with Significantly Higher Risks of Device Infection