Back to Authors

Cebral, Juan R.

https://orcid.org/0000-0002-3216-0856

Mayo Clinic

George Mason University

Citations 19

Hemodynamic characteristics of stable and unstable vertebrobasilar dolichoectatic and fusiform aneurysms
Brinjikji, Waleed , Chung, BongJae, Yong-Hong, Ding, Wald, John T. , Mut, Fernando , Kadirvel, Ramanathan , Kallmes, David F. , Rouchaud, Aymeric , Yong-Hong, Ding, Lanzino, Giuseppe , Cebral, Juan R. , Rouchaud, Aymeric

Journal of NeuroInterventional Surgery | March 16, 2018 | Volume: 10 | Issue: 11 | Pages: 1102-1107

10.1136/neurintsurg-2018-013756 Get It

Background and purpose Vertebrobasilar dolichoectatic and fusiform aneurysms (VBDAs) are known to have a poor natural history, with high rates of growth, rupture, and stroke. The purpose of this study was to identify hemodynamic characteristics that differ between VBDAs associated with growth, rupture, and stroke. Materials and methods VBDAs with CT angiography or MR angiography followed longitudinally without treatment were studied. Unstable aneurysms were defined as those that grew or ruptured during follow-up. Aneurysms associated with stroke were defined as those associated with posterior circulation infarct at follow-up. Baseline data, including demographics, comorbidities, and aneurysm morphology and size were collected. Image based computational fluid dynamics models were created and run under pulsatile flow conditions. Relevant hemodynamic and geometric variables were calculated and compared between groups (stable vs unstable and no stroke vs stroke) using the Wilcoxon test. Results A total of 37 VBDAs were included (24 stable, 13 unstable; 30 no stroke, 7 stroke). Unstable aneurysms had lower shear rates (P=0.05), blood flow velocity (P=0.03), and lower vorticity (P=0.049) than stable aneurysms. In addition, unstable aneurysms had higher mean oscillatory shear indices (P=0.001). There were no differences in the hemodynamic characteristics of aneurysms in the stroke group compared with the non-stroke group. Conclusion This small study suggests there may be hemodynamic differences between unstable and stable VBDAs. Unstable VBDAs appear to be under lower flow conditions with lower velocity, vorticity, and shear rates, and have more oscillatory flow. There was no difference in the hemodynamic characteristics of aneurysms in the stroke and no stroke group.
A data-driven approach for addressing the lack of flow waveform data in studies of cerebral arterial flow in older adults*
Durka, Michael J. , Wong, Isaac H, Kallmes, David F. , Pasalic, Dario , Mut, Fernando , Jagani, Manoj, Blanco, Pablo J. , Robertson, Anne M. , Robertson, Anne M , Cebral, Juan R.

Physiological Measurement | December 5, 2017 | Volume: 39 | Issue: 1 | Pages: 015006

10.1088/1361-6579/aa9f46 Get It

Abstract Objective : Blood flow waveforms—essential data for hemodynamic modeling—are often in practice unavailable to researchers. The objectives of this work were to assess the variability among the waveforms for a clinically relevant older population, and develop data-based methods for addressing the missing waveform data for hemodynamic studies. Approach : We analyzed 272 flow waveforms from the internal carotid arteries of older patients (73 ± 13 yr) with moderate cardiovascular disease, and used these data to develop methods to guide new approaches for hemodynamic studies. Main results : Profound variations in waveform parameters were found within the aged population that were not seen in published data for young subjects. Common features in the aged population relative to the young included a larger systole-to-diastole flow rate ratio, increased flow during late systole, and absence of a dicrotic notch. Eight waveforms were identified that collectively represent the range of waveforms in the older population. A relationship between waveform shape and flow rate was obtained that, in conjunction with equations relating flow rate to diameter, can be used to provide individualized waveforms for patient-specific geometries. The dependence of flow rate on diameter was statistically different between male and female patients. Significance : It was shown that a single archetypal waveform cannot well-represent the diverse waveforms found within an aged population, although this approach is frequently used in studies of flow in the cerebral vasculature. Motivated by these results, we provided a set of eight waveforms that can be used to assess the hemodynamic uncertainty associated with the lack of patient-specific waveform data. We also provided a methodology for generating individualized waveforms when patient gender, age, and cardiovascular disease state are known. These data-driven approaches can be used to devise more relevant in vitro or in silico intra-cranial hemodynamic studies for older patients.
Hemodynamic differences between unstable and stable unruptured aneurysms independent of size and location: a pilot study
Brinjikji, Waleed , Chung, Bong Jae , Jiménez, Carlos , Putman, Christopher M. , Kallmes, David F. , Cebral, Juan R.

Journal of NeuroInterventional Surgery | April 5, 2016 | Volume: 9 | Issue: 4 | Pages: 376-380

10.1136/neurintsurg-2016-012327 Get It

Background While clinical and angiographic risk factors for intracranial aneurysm instability are well established, it is reasonable to postulate that intra-aneurysmal hemodynamics also have a role in aneurysm instability. Objective To identify hemodynamic characteristics that differ between radiologically unstable and stable unruptured intracranial aneurysms. Materials and methods 12 pairs of unruptured intracranial aneurysms with a 3D rotational angiographic set of images and followed up longitudinally without treatment were studied. Each pair consisted of one stable aneurysm (no change on serial imaging) and one unstable aneurysm (demonstrated growth of at least 1 mm diameter or ruptured during follow-up) of matching size (within 10%) and locations. Patient-specific computational fluid dynamics models were created and run under pulsatile flow conditions. Relevant hemodynamic and geometric variables were calculated and compared between groups using the paired Wilcoxon test. Results The area of the aneurysm under low wall shear stress (low shear stress area (LSA)) was 2.26 times larger in unstable aneurysms than in stable aneurysms (p=0.0499). The mean aneurysm vorticity was smaller by a factor of 0.57 in unstable aneurysms compared with stable aneurysms (p=0.0499). No statistically significant differences in geometric variables or shape indices were found. Conclusions This pilot study suggests there may be hemodynamic differences between unstable and stable unruptured cerebral aneurysms. In particular, the area under low wall shear stress was larger in unstable aneurysms. These findings should be considered tentative until confirmed by future larger studies.
The Computational Fluid Dynamics Rupture Challenge 2013—Phase II: Variability of Hemodynamic Simulations in Two Intracranial Aneurysms
Berg, Philipp , Roloff, Christoph, Beuing, Oliver , Voß, Samuel , Sugiyama, Shin‐ichiro , Aristokleous, Nicolas , Αnayiotos, Αndreas , Ashton, Neil , Revell, Alistair , Bressloff, Neil W. , Brown, Alistair, Chung, Bong Jae , Copelli, Gabriele, Fu, Wenyu , Geers, Arjan J. , Hodis, Simona , Dragomir‐Daescu, Dan , Nordahl, Emily Rose, Suzen, Yildirim , Khan, Muhammad Owais , Valen‐Sendstad, Kristian , Kono, Kenichi , Menon, Prahlad G. , Albal, Priti G., Mierka, Otto , Münster, Raphael , Bonnefous, Odile , Osman, Jan , Goubergrits, Leonid , Pallarès, Jordi , Cito, Salvatore , Passalacqua, Alberto , Pişkin, Şenol , Pekkan, Kerem , Ramalho, Susana, Marques, N. P. C. , Sanchi, Stéphane, Schumacher, Kristopher R., Sturgeon, Jess, Švihlová, Helena , Hron, J. , Usera, Gabriel , Mendina, Mariana , Xiang, Jianping , Steinman, David A. , Cebral, Juan R. , Qiao, Aike , Morales, Hernán G. , Meng, Hui , Janiga, Gábor , Hron, Jaroslav , Švihlová, Helena

Journal of Biomechanical Engineering | October 16, 2015 | Volume: 137 | Issue: 12 | Pages: No page available

10.1115/1.4031794 Get It

With the increased availability of computational resources, the past decade has seen a rise in the use of computational fluid dynamics (CFD) for medical applications. There has been an increase in the application of CFD to attempt to predict the rupture of intracranial aneurysms, however, while many hemodynamic parameters can be obtained from these computations, to date, no consistent methodology for the prediction of the rupture has been identified. One particular challenge to CFD is that many factors contribute to its accuracy; the mesh resolution and spatial/temporal discretization can alone contribute to a variation in accuracy. This failure to identify the importance of these factors and identify a methodology for the prediction of ruptures has limited the acceptance of CFD among physicians for rupture prediction. The International CFD Rupture Challenge 2013 seeks to comment on the sensitivity of these various CFD assumptions to predict the rupture by undertaking a comparison of the rupture and blood-flow predictions from a wide range of independent participants utilizing a range of CFD approaches. Twenty-six groups from 15 countries took part in the challenge. Participants were provided with surface models of two intracranial aneurysms and asked to carry out the corresponding hemodynamics simulations, free to choose their own mesh, solver, and temporal discretization. They were requested to submit velocity and pressure predictions along the centerline and on specified planes. The first phase of the challenge, described in a separate paper, was aimed at predicting which of the two aneurysms had previously ruptured and where the rupture site was located. The second phase, described in this paper, aims to assess the variability of the solutions and the sensitivity to the modeling assumptions. Participants were free to choose boundary conditions in the first phase, whereas they were prescribed in the second phase but all other CFD modeling parameters were not prescribed. In order to compare the computational results of one representative group with experimental results, steady-flow measurements using particle image velocimetry (PIV) were carried out in a silicone model of one of the provided aneurysms. Approximately 80% of the participating groups generated similar results. Both velocity and pressure computations were in good agreement with each other for cycle-averaged and peak-systolic predictions. Most apparent “outliers” (results that stand out of the collective) were observed to have underestimated velocity levels compared to the majority of solutions, but nevertheless identified comparable flow structures. In only two cases, the results deviate by over 35% from the mean solution of all the participants. Results of steady CFD simulations of the representative group and PIV experiments were in good agreement. The study demonstrated that while a range of numerical schemes, mesh resolution, and solvers was used, similar flow predictions were observed in the majority of cases. To further validate the computational results, it is suggested that time-dependent measurements should be conducted in the future. However, it is recognized that this study does not include the biological aspects of the aneurysm, which needs to be considered to be able to more precisely identify the specific rupture risk of an intracranial aneurysm.
Gene expression comparison of flow diversion and coiling in an experimental aneurysm model
Puffer, Cole, Ding, Yong-Hong, Kallmes, David F. , Kadirvel, Ramanathan , Dai, Daying , Kallmes, David, Ding, Yonghong , Cebral, Juan R.

Journal of NeuroInterventional Surgery | October 20, 2014 | Volume: 7 | Issue: 12 | Pages: 926-930

10.1136/neurintsurg-2014-011452 Get It

Background and purpose Mechanisms of both healing and complications, including spontaneous aneurysm rupture, remain unclear following flow diverter treatment. The aim of this study was to compare gene expression of various key molecules involved in the healing of aneurysms, between aneurysms treated with microcoils and flow diverters. Methods Saccular aneurysms were created in rabbits. Aneurysms were treated with coils (n=6) or flow diverters (n=6). Aneurysms were harvested at 4 weeks following treatment and used for gene expression and zymography experiments. Genes with a fold change of 1.2 or more were considered upregulated whereas those with a fold change of 0.8 or less were considered downregulated. Results All coil embolized aneurysms were completely occluded at follow-up. Two aneurysms were occluded and the remaining four samples were incompletely occluded in the flow diverter treated group. The following genes were expressed at lower levels in the flow diverter group compared with the coiled aneurysm group: proteinases (matrix metalloproteinases 2 and 9), cellular markers (endothelial nitric oxide synthase and smooth muscle actin), and structural proteins (collagens and fibronectin). Genes related to inflammation (tumor necrosis factor α and monocyte chemoattractant protein 1) were upregulated in flow diverter treated aneurysms compared with coil embolized aneurysms. Notably, the enzymatic activity of active matrix metalloproteinase 9 was high in aneurysms treated with flow diverters. Conclusions Our findings may provide improved understanding of rupture risk and healing following aneurysm treatment and inform development of therapies aimed at lowering rupture risk and accelerating healing.
Analysis of flow changes in side branches jailed by flow diverters in rabbit models
Raschi, Marcelo , Mut, Fernando , Ding, Yong‐Hond, Kadirvel, Ramanathan , Kallmes, David F. , Cebral, Juan R. , Dai, Daying

International Journal for Numerical Methods in Biomedical Engineering | April 14, 2014 | Volume: 30 | Issue: 10 | Pages: 988-999

10.1002/cnm.2640 Get It

SUMMARYUnderstanding the flow alteration in side branches during flow diversion treatment of cerebral aneurysms is important to prevent ischemic complications and improve device designs. Flow diverters were placed in the aorta of four rabbits crossing the origin of side arteries. Subject‐specific computational models were constructed from 3D angiographies and Doppler ultrasounds (DUSs). Flow simulations were run before and after virtually deploying the flow diverters, assuming distal resistances remained unchanged after treatment. All jailed arteries remained patent angiographically 8 weeks after treatment. The computational models estimated decreases compared to pretreatment in the mean flow rates between 2% and 20% and in peak flow rates between 5% and 36%. The major changes were observed during systole. Flow patterns did not exhibit recirculation zones before treatment. Implantation of the flow diverters altered the flow structure only locally near the device wires. No major recirculation regions were created or destroyed. Flow diverters seem safe with respect to perforator or side branch occlusion. Relatively small changes in flow rates through jailed arteries are expected, even for moderate to large degrees of coverage of their origins. These results seem consistent with previous clinical experiences where no or very few complications related to perforator occlusion have been reported.Copyright © 2014 John Wiley & Sons, Ltd.
Strategy for analysis of flow diverting devices based on multi‐modality image‐based modeling
Mut, Fernando , Raschi, Marcelo , Kadirvel, Ramanathan , Kallmes, David F. , Cebral, Juan R. , Ding, Yonghong

International Journal for Numerical Methods in Biomedical Engineering | April 9, 2014 | Volume: 30 | Issue: 10 | Pages: 951-968

10.1002/cnm.2638 Get It

SUMMARY Quantification and characterization of the hemodynamic environment created after flow diversion treatment of cerebral aneurysms is important to understand the effects of flow diverters and their interactions with the biology of the aneurysm wall and the thrombosis process that takes place subsequently. This paper describes the construction of multi‐modality image‐based subject‐specific CFD models of experimentally created aneurysms in rabbits and subsequently treated with flow diverters. Briefly, anatomical models were constructed from 3D rotational angiography images, flow conditions were derived from Doppler ultrasound measurements, stent models were created and virtually deployed, and the results were compared with in vivo digital subtraction angiography and Doppler ultrasound images. The models were capable of reproducing in vivo observations, including velocity waveforms measured in the parent artery, peak velocity values measured in the aneurysm, and flow structures observed with digital subtraction angiography before and after deployment of flow diverters. The results indicate that regions of aneurysm occlusion after flow diversion coincide with slow and smooth flow patterns, whereas regions still permeable at the time of animal sacrifice were observed in parts of the aneurysm exposed to larger flow activity, that is, higher velocities, more swirling, and more complex flow structures. Copyright © 2014 John Wiley & Sons, Ltd.
Flow Diversion in Rabbit Aneurysm Models
Mut, Fernando , Raschi, Marcelo , Kadirvel, Ramanathan , Kallmes, David F. , Cebral, Juan R.

Volume 1A: Abdominal Aortic Aneurysms; Active and Reactive Soft Matter; Atherosclerosis; BioFluid Mechanics; Education; Biotrans | January 29, 2014 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/sbc2013-14254 Get It

Flow diversion treatment of cerebral aneurysms has increasingly been considered, especially for large complex aneurysms with wide necks that are difficult to treat with coils of by clipping. However, the relationship between the hemodynamic environment created immediately after implantation of flow diverters (FD) and the subsequent aneurysm occlusion is poorly understood [1].
Analysis of Blood Flow Through Side Branches Jailed by Flow Diverters in Rabbit Models
Mut, Fernando , Raschi, Marcelo , Kadirvel, Ramanathan , Kallmes, David F. , Cebral, Juan R.

Volume 1B: Extremity; Fluid Mechanics; Gait; Growth, Remodeling, and Repair; Heart Valves; Injury Biomechanics; Mechanotransduct | January 29, 2014 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/sbc2013-14258 Get It

Since treatment of cerebral aneurysms with flow diverters (FD) has gained much attention in recent years, it is important to understand what is the effect of these devices on the flow through arteries jailed or crossed by these devices [1].