Back to Authors

Meiling, James B

0000-0002-2725-1825

Mayo Clinic

Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, Minnesota, U.S.A.

Citations 27

Ultrasound Depiction of the Optimal Window for Needle Placement for Electromyography of the Short Head of the Biceps Femoris
Hass, Reece M. , Mitchell, C., Meiling, James B. , Litchy, William J. , Boon, Andrea J. , Hass, Reece M. , Mitchell, Cecilia V , Meiling, James B

Muscle & Nerve | January 19, 2026 | Volume: 73 | Issue: 4 | Pages: 630-634

10.1002/mus.70154 Get It

ABSTRACT Introduction/Aims Accurate needle electromyography (EMG) of the short head of the biceps femoris (SHBF) is often important to localize nerve damage when proximal to the fibular head. Techniques have been proposed for accurate SHBF EMG; however, needle placement accuracy is low and with the risk of inadvertent needle placement into the long head (LHBF) potentially resulting in false localization and inappropriate operative management. This study aimed to define the optimal window for accurate SHBF needle EMG placement through ultrasound (US) investigation of the anatomical relationships of the SHBF, LHBF, and common fibular nerve (CFN) in the distal posterolateral thigh. Methods Forty lower limbs from 20 healthy adults were evaluated using US. Distances from the popliteal crease (PC) to the SHBF and LHBF myotendinous junctions and position of the CFN in the popliteal fossa were recorded. The “SHBF window” was defined as the region where the SHBF muscle body is present in the absence of the LHBF. Results The SHBF was located anterolateral to the LHBF tendon/muscle and the CFN medial to the SHBF in all limbs. The average distances from the PC to SHBF and LHBF muscles were 0.6 and 6.4 cm, respectively. The optimal “SHBF window” was identified to be 3–4 cm (2–3 fingerbreadths) proximal to the PC, anterolateral to the LHBF tendon in the distal thigh. Discussion SHBF examination within this optimized window results in increased accuracy of needle placement, aiding in the electrodiagnostic localization of fibular nerve lesions.
Combined Use of EMG and Muscle Ultrasound for the Evaluation of Scapular Winging
Rardin, Benjamin, Meiling, James B. , Cartwright, Michael S., Rardin, Benjamin P , Meiling, James B , Cartwright, Michael S. , Caress, James B.

Muscle & Nerve | January 16, 2026 | Volume: 73 | Issue: 3 | Pages: 495-499

10.1002/mus.70134 Get It

ABSTRACT Introduction/Aims Scapular winging occurs as an abnormal protrusion of the scapula due to nerve injury, muscle weakness, bone, or joint pathology. The main muscular stabilizers of the scapula include the serratus anterior, trapezius, rhomboid major and minor, levator scapulae, and pectoralis minor. Needle electromyography (EMG) has historically been used as one of the primary diagnostic tests for evaluating this finding. However, sampling of these muscles can be technically difficult and carries risks for complications. Muscle ultrasound (MUS) can also reliably identify abnormalities in the muscles involved in scapular stabilization while offering the benefit of rapid side‐to‐side comparison and improved patient comfort. This study aims to highlight the concordance of ultrasound and EMG findings using our published MUS protocol in patients with scapular winging. Methods A retrospective analysis was performed of 13 patients who presented to an electrodiagnostic (EDX) laboratory with the referral diagnosis of “scapular winging” or “scapular dyskinesis.” All patients underwent MUS testing of scapular muscles according to a previously published protocol followed by EMG of muscles deemed relevant by the clinician. Results Seven patients were found to have a neurogenic cause of their scapular winging and in those patients, all had both EMG and MUS abnormalities. MUS was found to have a sensitivity of 87.5%, specificity of 95.7%, and individual muscle concordance with EMG of 90.6%. Discussion There is high concordance between EMG and MUS in patients with scapular winging. This combined with potential advantages of the MUS modality supports their concurrent use in patients with scapular winging.
Pediatric Neuromuscular Ultrasound to Augment the Diagnostic Capabilities for Scapular Winging
White, M. , Meiling, James B. , Cossette, Katie, Rabatin, Amy E. , White, Melanie J , Pulos, Nicholas A, Rabatin, Amy E , Meiling, James B , Pulos, Nicholas

Journal of Clinical Ultrasound | November 27, 2025 | Volume: 54 | Issue: 4 | Pages: 1025-1027

10.1002/jcu.70147 Get It

ABSTRACT Scapular winging (SW) describes abnormal scapular mechanics from weak stabilizing muscles or altered neural innervation. While electromyography (EMG) helps differentiate between myo‐ or neuropathic SW etiologies and determine the extent of muscle involvement, pediatric EMG may be limited due to the high risk of surrounding structures, small body habitus, and pain tolerance. Herein is a case of pediatric SW following anterior neck lymphadenopathy resection in which EMG was limited. Neuromuscular ultrasound (NMUS) showed asymmetric trapezius thinning and hyperechogenicity, revealing more expansive involvement than was previously known. NMUS is a painless, validated tool to augment the diagnostic capability of EMG and clarify the extent of neuromuscular involvement in SW from both a prognostic and rehabilitation point of view.
Fascial Border Absence Between the Extensor Carpi Radialis Longus and Brachioradialis Muscles
Meiling, James B. , Wu, Kitty Y. , Luetmer, Marianne T. , Boon, Andrea J. , Meiling, James B

Muscle & Nerve | November 21, 2025 | Volume: 73 | Issue: 1 | Pages: 93-96

10.1002/mus.70077 Get It

ABSTRACT Introduction/Aims Ultrasound (US) guidance may ensure proper needle placement during electromyography (EMG) when assessing for suitable donor muscles for upper limb reconstruction. A distinct intermuscular fascial border aids in delineating the separation between the brachioradialis (BR) and extensor carpi radialis longus (ECRL) muscles. However, this border may be absent, making correct needle placement complex and assessment more difficult. The purpose of this study was to describe the presence and absence of this fascial border in healthy individuals to help with accurate EMG needle placement. Methods Twenty healthy patients underwent sonographic examination by a single sonographer physician of the ECRL and BR to identify the presence or absence of the intermuscular fascial border. Results The fascial border that routinely separates the ECRL and BR was absent in at least one arm in 20% of subjects (12.5% of upper limbs). One subject had an absent fascial border in both upper limbs. Discussion US can assess for the presence or absence of intermuscular fascial borders. This assessment is important for accurate EMG needle placement and localization. While the clinical significance of an absent ECRL‐BR fascial border is currently unknown, future studies should examine the effect of absent ECRL‐BR fascial borders on wrist extension.
Neuromuscular Ultrasound of a Common Fibular Nerve Intraneural Ganglion Cyst With Selective Involvement of the Deep Fibular Fascicles
Buttinger, Jessica N., Carter, Julia T., Meiling, James B. , Meiling, James B

Journal of Clinical Neuromuscular Disease | September 3, 2025 | Volume: 27 | Issue: 1 | Pages: 26-27

10.1097/cnd.0000000000000537 Get It

Diagnostic Neuromuscular Ultrasonography of Spinal Accessory Nerve Injury After Cosmetic Rhytidectomy
Kopacz, Kira S., Mauermann, Michelle L. , Laughlin, Ruple S. , Sellon, Jacob L. , Spinner, Robert J., Meiling, James B. , Pulos, Nicholas A, Meiling, James B , Mauermann, Michelle L , Kopacz, Konrad, Shin, Alexander Y. , Pulos, Nicholas , Bishop, Allen T. , Maldonado, Andrés A. , Spinner, Robert J.

Journal of Clinical Ultrasound | July 21, 2025 | Volume: 53 | Issue: 9 | Pages: 2210-2214

10.1002/jcu.70015 Get It

ABSTRACT Iatrogenic spinal accessory nerve (SAN) injuries can occur as complications of posterior triangle of the neck surgery, resulting in lateral scapular winging and a shoulder droop. Rarely has this complication been described after a cosmetic rhytidectomy (face‐lift procedure). Here, we present two cases of iatrogenic SAN injuries that occurred after cosmetic rhytidectomies. The use of electrodiagnostic and ultrasound examinations provides invaluable information to assess peripheral nerve injuries. Electrodiagnostic testing can confirm the presence and severity of the injury, while ultrasound can provide additional anatomical information and direct visualization to confirm the continuity of the nerve and assess muscle denervation changes.
Ultrasonographic Identification of Pacinian Corpuscles in the Hand: A Pilot Study of Technique and Reliability
Miller, Nicholas J. , Meiling, James B. , Walker, Francis O. , Meiling, James B , Cartwright, Michael S.

Muscle & Nerve | April 29, 2025 | Volume: 72 | Issue: 1 | Pages: 93-99

10.1002/mus.28423 Get It

ABSTRACTIntroduction/AimsPacinian corpuscles are end organs of the sensory nervous system. The size and superficial location of Pacinian corpuscles allows them to be visualized with high‐resolution ultrasound. This pilot study sought to assess the reliability of Pacinian corpuscle counting in the hand using ultrasound.MethodsTwo healthy participants underwent ultrasound evaluation by three ultrasonographers using a scanning protocol developed for this study. The ultrasound protocol used anatomic landmarks to identify and trace digital nerves in the palms and the adjacent Pacinian corpuscles. The ultrasonographers used morphologic features to identify and count Pacinian corpuscles at two sites in each hand for each participant using a 10–22 MHz linear‐array transducer. The procedure was repeated at 2 time points. Inter‐rater and intrarater reliabilities were determined using intraclass correlation coefficients (ICCs).ResultsPacinian corpuscles were identified in the second–third and fourth–fifth intermetacarpal spaces. The ultrasound appearance of Pacinian corpuscles is of a hypoechoic, rounded structure without a hyperechoic rim. A clustered appearance and septate internal structure are distinct features of Pacinian corpuscles, but these features are not always present. The mean number at each site was between 10.71 and 11.71. Inter‐rater and intrarater reliability both resulted in ICC values over 0.8, indicating “good” inter‐rater and intrarater reliabilities.DiscussionPacinian corpuscles can be reliably counted in the hand using high‐resolution ultrasound. The reliability data from this pilot study may facilitate further ultrasound studies of Pacinian corpuscles, which may be decreased in number or undergo other changes in polyneuropathies.
Neuromuscular Ultrasound Assessment of the Median Nerve at the Wrist and Forearm: A Reproducibility and Reliability Study in Nonphysician Sonographers
Meiling, James B. , Boon, Andrea J. , Sorenson, Eric J. , Litchy, William J. , Meiling, James B

Muscle & Nerve | April 28, 2025 | Volume: 72 | Issue: 1 | Pages: 130-133

10.1002/mus.28424 Get It

ABSTRACTIntroduction/AimsNeuromuscular ultrasound (NMUS), initially performed by physicians, is increasingly performed by technicians in many electrodiagnostic (EDX) laboratories for certain studies under physician supervision. The aims of this study were to determine: (1) the reproducibility of nonphysician sonographers' assessments of the median nerve and (2) the need for ongoing training to maintain the reproducibility and reliability of median nerve ultrasound assessments.MethodsThe median nerve was examined sonographically in a healthy volunteer by 12 nonphysicians on 3 separate occasions: Day 1 and then 2 weeks (Day 2) and 4 months (Day 3) later. Cross‐sectional area (CSA) and wrist‐to‐forearm ratios (WFRs) were calculated each time. Sonographers were retrained prior to Day 2. Reproducibility and reliability were determined using coefficients of variation calculated for each characteristic for each day and each nonphysician sonographer, comparing performance across the 3 time points.ResultsThere was overall less variation for each characteristic (wrist CSA, forearm CSA, and WFR) on Day 2 compared to Day 1 (coefficients of variation 3.0%, 5.4%, and 5.7% vs. 8.8%, 15.5%, and 11.3%, respectively), both when viewed at the group and individual levels, indicating an improvement in reproducibility and reliability after the retraining session. The improvement was similar for Day 3.DiscussionThis study demonstrates the need for training and subsequent retraining sessions to ensure the reproducibility and reliability of NMUS measurements in the median nerve.
Brachial plexus neuromuscular ultrasound in neuralgic amyotrophy
Feaster, Brandon W, Meiling, James B. , Meiling, James B

BMJ Case Reports | April 11, 2025 | Volume: 18 | Issue: 4 | Pages: e265588

10.1136/bcr-2025-265588 Get It

Miller Fisher Syndrome With an Electrophysiologic Phenotype of Sensory Neuronopathy
Meiling, James B. , Miller, Nicholas J. , Meiling, James B , Caress, James B.

Journal of Clinical Neuromuscular Disease | February 26, 2025 | Volume: 26 | Issue: 3 | Pages: 111-113

10.1097/cnd.0000000000000511 Get It