Back to Authors

Rodriguez-Riascos, Juan F

0000-0002-8271-9128

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, AZ (M.S., J.F.R.-R., H.S.V., J.K., K.S.).

Citations 13

Safety and Efficacy of Pulsed Field Ablation for Cavotricuspid Isthmus-Dependent Flutter: A Systematic Literature Review
Rodriguez, Juan F. , Muthu, Padmapriya , Prajapati, Poojan , Su, Felice , Shen, Win K., Valverde, Arturo M. , Rodriguez-Riascos, Juan F , Muthu, Padmapriya , Vemulapalli, Hema Srikanth , Su, Wilber , Srivathsan, Komandoor

No container title available | March 23, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.174275286.60150110/v1 Get It

Background: Cavotricuspid isthmus ablation (CTI) is a first line therapy in patients with typical atrial flutter. With the advent of Pulsed Field (PF) as a new energy source, we sought to evaluate the use of PF for CTI ablation. A systematic literature search was conducted on the use of PF for CTI-flutter up to December 2024. A meta-analysis was performed for studies reporting pooled data, while a patient-level summary was done for reports with available individual data. The mean number of PF applications, acute success rate, and prevalence of coronary vasospasm were evaluated. Results: Eleven studies with pooled data from 155 patients were included. All patients had an acute block of the CTI. The mean number of PFA applications was 7.78 (95% CI 6.53–9.48). The incidence of ST-elevation was 0.04% (95% CI 0-2.23%). Subclinical vasospasm was documented in 45% (95% CI 32%–59%) of patients who underwent periprocedural coronary angiography. Prophylactic use of nitrates showed a trend toward reducing the incidence of subclinical vasospasm (RR 0.24, 95% CI 0.06–1.06, p=0.059). Twelve cases with patient-level data were included; six reported complications, including ST elevation and conduction disturbances. Conclusion: PFA for CTI flutter demonstrates high acute success; however, evidence regarding the durability of the block is limited. Clinical vasospasm with ST segment elevation is uncommon but can lead to life-threatening complications. The incidence of subclinical vasospasm is high, and nitrates trend toward reducing this phenomenon. To date, the role of PFA for this condition appears to be limited.
Atrioventricular Node Ablation for Atrial Fibrillation in a Patient With EVOQUE Tricuspid Valve: A First Reported Case
Muthu, Padmapriya , Vemulapalli, Hema Srikanth , Prajapati, Poojan , Rodriguez, Juan F. , Lone, Ahmad Naeem, Srivathsan, Komandoor , Vemulapalli, Hema S , Rodriguez-Riascos, Juan F , Srivathsan, Komandoor , Muthu, Padmapriya

Journal of Cardiovascular Electrophysiology | March 11, 2025 | Volume: 36 | Issue: 5 | Pages: 1107-1111

10.1111/jce.16633 Get It

ABSTRACT Introduction Atrial fibrillation (AF) is the most common arrhythmia, and atrioventricular (AV) node ablation with pacemaker implantation is a therapeutic option for refractory cases. However, AV node ablation in patients with bioprosthetic tricuspid valves poses technical challenges. Methods An 84‐year‐old male with an EVOQUE transcatheter tricuspid valve replacement underwent AV node ablation (AVNA) under intracardiac echocardiography (ICE) guidance. Results Successful AV block was achieved with precise catheter positioning, improving the patient's symptoms and ventricular rate control. Conclusion This case demonstrates the feasibility of AVNA in patients with tricuspid bioprostheses, demonstrating feasibility with ICE guidance.
Atrioventricular Node Ablation for Atrial Fibrillation in a Patient with EVOQUE Tricuspid Valve: A First Reported Case
Muthu, Padmapriya , Prajapati, Poojan , Rodriguez, Juan F. , Lone, Ahmad Naeem, Rodriguez-Riascos, Juan F , Muthu, Padmapriya , Vemulapalli, Hema Srikanth , Srivathsan, Komandoor

No container title available | January 23, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.173763833.36784520/v1 Get It

This is the first reported case of atrioventricular node ablation (AVNA) in a patient with an EVOQUE transcatheter tricuspid valve, performed for refractory atrial fibrillation with uncontrolled ventricular rates. This case highlights the feasibility and importance of advanced imaging techniques in managing arrhythmias in patients with bioprosthetic valves, offering insights into expanding therapeutic options for complex cardiovascular conditions.