Schirger, John A.

Mayo Clinic

Mayo Clinic

Citations 36

Abstract 5432: Mutation of Three Amino Acids in the Disulfide-Ring of a CNP Based Chimeric Natriuretic Peptide Alters its Vascular Properties
Chen, Horng H. , Huntley, Brenda K., Lee, Candace Y., Martín, Fernando L., Schirger, John A., Burnett, John C. , Lee, Candace Y.W.

Circulation | July 3, 2021 | Volume: 118 | Issue: suppl_18 | Pages: No page available

10.1161/circ.118.suppl_18.s_549-c Get It

BACKGROUND: C-type natriuretic peptide (CNP) is a 22-amino-acid peptide produced mainly in the endothelium with potent cardiac unloading and modest blood pressure lowering actions, but minimal renal actions. Based on our previous knowledge, we recently fused a 6 aa sequence from BNP to the C-terminus and a 5 aa sequence from ANP to the N-terminus of CNP. This novel hybrid peptide, CBA-NP, has cardiac unloading actions and mild hypotensive effects similar to CNP. Importantly however, the N and C terminus alterations resulted in potent renal excretory actions. here we test the hypothesis that the 3 aa GSM 15–17 in the disulfide-ring mediate the vascular and hypotensive actions. We therefore mutated GSM 15–17 to REA 15–17 , which we named ABC-NP and compared its in vivo and in vitro actions to CBA-NP. METHODS: We determined the cardiorenal and humoral actions of intravenous bolus administration of CBA-NP (n=5) and ABC-NP (n=5) at 25 microgram/Kg in 2 separate group of normal anesthetized dogs. We also assessed the cGMP response of both peptides in human aortic endothelial cells (HAEC), human cardiac fibroblast (HCF) and isolated canine glomeruli. * p<0.05 RESULTS: IV bolus administration of CBA-NP and ABC-NP resulted in diuresis* and natriuresis*. There was a significant decrease in mean arterial blood (MAP) pressure with CBA-NP (126±6 to113±7 mmHg*) but no change with ABC-NP(126±8 to126±8 mmHg) . In addition, the reduction in pulmonary capillary wedge pressure (PCWP) and right atrial pressure (RAP) was significantly greater with CBA-NP as compared to ABC-NP. cGMP generation in HAEC and HCF was minimal with ABC-NP and was significantly higher with CBA-NP*. In contrast, cGMP generation was similar in isolated glomeruli between the two peptides. CONCLUSION: Our studies demonstrates that mutation of three amino acid (aa) residues within the CNP ring of CBA-NP from GSM 15–17 to REA alters the vascular but not the renal excretory properties. Hence by this strategic mutation within the ring of CBA-NP, we have designed a renal specific peptide ABC-NP resulting in new sequence specific functional information which can be used to design organ specific therapeutic peptides with unique properties tailored for a specific disease state.
Natural History of Patients Diagnosed with Cardiac Sarcoidosis at Left Ventricular Assist Device Implantation or Cardiac Transplantation
Schmidt, Tyler , Rosenbaum, Andrew , Kolluri, Nikhil , Stulak, John M., Daly, Richard C. , Schirger, John A., Elwazir, Mohamed Y. , Kapa, Suraj , Blauwet, Lori A., Schmidt, Tyler J , Rosenbaum, Andrew N , Kapa, Suraj , Elwazir, Mohamed , Cooper, Leslie T.

ASAIO Journal | September 6, 2020 | Volume: 67 | Issue: 5 | Pages: 583-587

10.1097/mat.0000000000001262 Get It

To our knowledge, natural history has not been reported for cardiac sarcoidosis (CS) diagnosed by pathologic evaluation of the apical core at left ventricular assist device (LVAD) implantation or cardiac transplantation. We retrospectively identified 232 consecutive patients meeting CS criteria. Of these patients, 54 were diagnosed by pathologic confirmation of CS, 10 after evaluation of the apical core (LVAD implant) or explanted heart (transplant). We compared clinical characteristics at initial evaluation and outcomes for these 10 patients with those of 10 patients with known CS before LVAD implant/transplant. In the study group, five patients (50%) had confirmed extracardiac sarcoidosis before LVAD implant/transplant; five had not been diagnosed with sarcoidosis. Mean (standard deviation) left ventricular ejection fraction at initial evaluation was 23% (16%), and left ventricular end-diastolic dimension was 61 (10) mm. Four patients died during follow-up; however, no survival difference was found for the 10 patients diagnosed incidentally and the group with a previous diagnosis or institutional LVAD/transplant cohorts. Patients diagnosed with CS on pathological examination of the apical core/explanted heart may have severe dilated cardiomyopathy as the initial presentation. Outcomes for patients with CS after advanced heart failure therapies may be comparable with those of non-CS patients.
Outcomes of Ambulatory Heart Failure Patients Managed With an Intra-aortic Balloon Pump Before Left Ventricular Assist Device Implantation
Ternus, Bradley , Behfar, Atta , Schirger, John A., Barsness, Gregory W. , Eleid, Mackram F. , Patel, Parag C. , Stulak, John M., Schirger, John, Barsness, Gregory W , Eleid, Mackram, Jentzer, Jacob, Behfar, Atta , Jentzer, Jacob C.

ASAIO Journal | August 6, 2020 | Volume: 67 | Issue: 4 | Pages: 430-435

10.1097/mat.0000000000001249 Get It

Patients are admitted to the hospital for hemodynamic optimization before left ventricular assist device (LVAD) implantation. The aim of this study was to evaluate the clinical outcomes of hemodynamic optimization using an intra-aortic balloon pump (IABP) in ambulatory heart failure patients before LVAD placement. This retrospective single-center study included 199 noninotrope-dependent patients who underwent durable LVAD implantation between January 1, 2007 and April 10, 2017. Invasive hemodynamic as well as the primary composite end-point of stage 2 or 3 acute kidney injury, right ventricular failure, and 30-day mortality were compared between patients with and without an IABP. Median age was 64 (interquartile range [IQR], 57–71) years and 165 (82.9%) were male; 72 (36.2%) received an IABP. Patients treated with an IABP had worse baseline exercise capacity and hemodynamic parameters. Patients with an IABP had greater relative reduction in pulmonary artery mean pressure (−16% vs. −2%; p ≤ 0.001). The primary composite end-point was not different between patients who had an IABP and those who did not (20.8% vs. 20.5%; p = 0.952), as were each of the individual end-points. Despite worse baseline hemodynamic parameters and exercise capacity, ambulatory heart failure patients who received an IABP before LVAD implantation had more favorable reductions in pulmonary artery pressures without an increase in the composite end-point. These results suggest that IABP use before LVAD implantation may mitigate the risk of postoperative complications in ambulatory patients.
B-type natriuretic peptide and cardiac remodelling after myocardial infarction: a randomised trial
Hubers, Scott , Schirger, John A., Sangaralingham, S. Jeson , Chen, Yang , Burnett, John C. , Hodge, David O. , Chen, Horng H. , Hubers, Scott A , Hodge, David, Sangaralingham, S. Jeson

Heart | August 3, 2020 | Volume: 107 | Issue: 5 | Pages: 396-402

10.1136/heartjnl-2020-317182 Get It

Objective B-type natriuretic peptide (BNP) has favourable effects on left ventricular remodelling, including antifibrotic and antiapoptotic properties. We tested the hypothesis that infusion of BNP after an acute myocardial infarction would reduce left ventricular systolic and diastolic volumes and improve left ventricular ejection fraction compared with placebo. Methods A total of 58 patients who underwent successful revascularisation for an acute ST elevation anterior myocardial infarction were randomised to receive 72-hour infusion of BNP at 0.006 µg/kg/min or placebo. Left ventricular end diastolic and systolic volumes and left ventricular ejection fraction were measured at baseline and at 30 days by multigated acquisition scan. Left ventricular infarction size was measured by cardiac MRI. Results BNP infusion led to significantly higher BNP levels and plasma cyclic guanosine monophosphate at 72 hours. No significant difference in change of left ventricular volumes or ejection fraction from baseline to 30 days was observed between groups. Although left ventricular infarction size measured by cardiac MRI was not significantly different between BNP infusion versus placebo (p=0.39), there was a trend towards reduced infarction size in patients with a baseline ejection fraction of <40% (p=0.14). Conclusions Infusion of BNP in patients with an anterior myocardial infarction did not affect parameters of left ventricular remodelling. Patients treated with BNP who had a baseline left ventricular ejection fraction of <40% had a trend towards reduced left ventricular infarction size compared with placebo. These results do not support the use of intravenous BNP in patients after recent myocardial infarction. Trial registration number NCT00573144.
Left ventricle assist device pulsatility index at the time of implantation is associated with follow-up pulmonary hemodynamics
Sajgalik, Pavol , Kushwaha, Sudhir S. , Olson, Lyle J. , Stulak, John M., Johnson, Bruce D. , Schirger, John A., Schaefer, Jacob J

The International Journal of Artificial Organs | January 27, 2020 | Volume: 43 | Issue: 7 | Pages: 452-460

10.1177/0391398819899403 Get It

HeartMate II left ventricular assist device controllers provide data including pulsatility index, reflecting the relationship between pump function and hemodynamics. We propose that a higher pulsatility index at hospital discharge following implant may be associated with less vascular congestion and improved clinical outcomes. A retrospective analysis of 40 patients (age 59.2 ± 10.3 years) supported with the HeartMate II devices was conducted. Data revealed moderate Pearson correlations between pulsatility index at discharge and right atrial pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, mean pulmonary arterial pressure, and pulmonary capillary wedge pressure, respectively, post-surgery (median of 377 days), demonstrating a stronger relationship when analyzed for the EPC controller (n = 28) only (r = −.57, p < .01; r = −.38, p < .05; r = −.59, p < .01; r = −.47, p = .01 and r = −.53, p < .01, respectively). The pulsatility index derived from the EPC controller was associated with the significant risk of re-hospitalization within 1 and 2 years after the implantation of left ventricular assist device; hazard ratio = 0.557 with 95% confidence interval (0.315–0.983), p = .04 and hazard ratio = .579 (0.341–0.984), p = .04. A higher pulsatility index at discharge was associated with greater volume unloading, lower pulmonary pressures, and lower risk of all-cause re-hospitalizations within 1 and 2 years post-surgery. As such, pump-derived data may provide additional value in predicting left ventricular assist device hemodynamics.
Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices
Cross, Troy J. , Sajgalik, Pavol , Fabián, Vratislav , Matera, Lukáš , Kushwaha, Sudhir S. , Maltais, Simon, Stulak, John M., Schirger, John A., Johnson, Bruce D. , Cross, Troy James

The International Journal of Artificial Organs | August 14, 2019 | Volume: 43 | Issue: 2 | Pages: 99-108

10.1177/0391398819868236 Get It

Introduction: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the ‘cuff pulsatility index’. Purpose: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. Methods: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m −2 ) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient’s dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). Results: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. Conclusions: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.
P6528Cardiorenal protection by subcutaneous cenderitide in experimental heart failure: a novel and safe therapeutic for humans with LVAD support
Schirger, John A., Wanek, Jacqueline R., Heublein, Denise M., Sangaralingham, S. Jeson , Chen, H H, Burnett, John C. , Ichiki, Tomoko , Scott, Christopher G. , Sangaralingham, S. Jeson

European Heart Journal | December 10, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy566.p6528 Get It

Pulmonary Function Assessment Post-Left Ventricular Assist Device Implantation
Sajgalik, Pavol , Kim, Chul‐Ho , Stulak, John M., Kushwaha, Sudhir S. , Maltais, Simon, Joyce, David L. , Joyce, Lyle D., Johnson, Bruce D. , Schirger, John A.

ESC Heart Failure | October 12, 2018 | Volume: 6 | Issue: 1 | Pages: 53-61

10.1002/ehf2.12348 Get It

Abstract Aim The lungs—and particularly the alveolar-capillary membrane—may be sensitive to continuous flow (CF) and pulmonary pressure alterations in heart failure (HF). We aimed to investigate long-term effects of CF pumps on respiratory function. Methods and results We conducted a retrospective study of patients with end-stage HF at our institution. We analysed pulmonary function tests [e.g. forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1)] and diffusing capacity of the lung for carbon monoxide (DLCO) from before and after left ventricular assist device (LVAD) implantation and compared them with invasive haemodynamic studies. Of the 274 patients screened, final study analysis involved 44 patients with end-stage HF who had CF LVAD implantation between 1 February 2007 and 31 December 2015 at our institution. These patients [mean (standard deviation, SD) age, 50 (9) years; male sex, n = 33, 75%] received either the HeartMate II (Thoratec Corp.) pump (77%) or the HeartWare (HeartWare International Inc.) pump. The mean (SD) left ventricular ejection fraction was 21% (13%). At a median of 237 days post-LVAD implantation, we observed significant DLCO decrease (−23%) since pre-implantation (P &lt; 0.001). ΔDLCO had an inverse relationship with changes in pulmonary capillary wedge pressure (PCWP) and right atrial pressure (RAP) from pre-LVAD to post-LVAD implantation: ΔDLCO to ΔPCWP (r = 0.50, P &lt; 0.01) and ΔDLCO to ΔRAP (r = 0.39, P &lt; 0.05). We observed other reductions in FEV1, FVC, and FEV1/FVC between pre-LVAD and post-LVAD implantation. In mean (SD) values, FEV1 changed from 2.3 (0.7) to 2.1 (0.7) (P = 0.005); FVC decreased from 3.2 (0.8) to 2.9 (0.9) (P = 0.01); and FEV1/FVC went from 0.72 (0.1) to 0.72 (0.1) (P = 0.50). Landmark survival analysis revealed that ΔDLCO from 6 months after LVAD implantation was predictive of death for HF patients [hazard ratio (95% confidence interval), 0.60 (0.28–0.98); P = 0.03]. Conclusions Pulmonary function did not improve after LVAD implantation. The degree of DLCO deterioration is related to haemodynamic status post-LVAD implantation. The ΔDLCO within 6 months post-operative was associated with survival.
Noninvasive Blood Pressure Monitor Designed for Patients With Heart Failure Supported with Continuous-Flow Left Ventricular Assist Devices
Sajgalik, Pavol , Křemen, Václav , Fabián, Vratislav , Maltais, Simon, Stulak, John M., Kushwaha, Sudhir S. , Joyce, Lyle D., Schirger, John A., Johnson, Bruce D. , Kremen, Vaclav

ASAIO Journal | March 14, 2018 | Volume: 65 | Issue: 2 | Pages: 127-133

10.1097/mat.0000000000000775 Get It

The gold standard for noninvasive blood pressure (BP) measurement, the Doppler technique, does not provide systolic blood pressure (SBP) and diastolic blood pressure (DBP) and may limit therapy outcomes. To improve patient care, we tested specifically designed experimental BP (ExpBP) monitor and the Doppler technique by comparing noninvasive measures to the intraarterial (I-A) BP in 31 patients with end-stage heart failure (4 females) 2.6 ± 3.4 days post-LVAD implantation (20 HeartMate II and 11 HeartWare). Bland–Altman plots revealed that the ExpBP monitor overestimated mean arterial pressure (MAP) by 1.2 (4.8) mm Hg (mean difference [standard deviation]), whereas the Doppler by 6.7 (5.8) mm Hg. The ExpBP SBP was overestimated by 0.8 (6.1) mm Hg and DBP by 1.9 (5.3) mm Hg compared with the respective I-A pressures. Both techniques achieved similar measurement reliability. In the measurement “success rate” expressed as a frequency (percent) of readable BP values per measurement attempts, Doppler accomplished 100% vs. 97%, 97%, and 94% of successful detections of MAP, SBP, and DBP provided by the ExpBP monitor. The ExpBP monitor demonstrated higher accuracy in the MAP assessment than the Doppler in addition to providing SBP and DBP in majority of subjects. Improved BP control may help to mitigate related neurologic adverse event rates.
Neutral endopeptidase inhibition potentiates the natriuretic actions of adrenomedullin
Lisý, Ondřej, Jougasaki, Michihisa , Schirger, John A., Chen, Horng H. , Barclay, Paul T., Burnett, John C.

American Journal of Physiology-Renal Physiology | December 23, 2017 | Volume: 275 | Issue: 3 | Pages: F410-F414

10.1152/ajprenal.1998.275.3.f410 Get It

Adrenomedullin (ADM) is a potent renal vasodilating and natriuretic peptide possessing a six amino acid disulfide ring. Neutral endopeptidase 24.11 (NEP) is localized in greatest abundance in the kidney and cleaves endogenous peptides like atrial natriuretic peptide, which also possesses a disulfide ring. We hypothesized that NEP inhibition potentiates the natriuretic actions of exogenous ADM in anesthetized dogs ( n = 6). We therefore investigated renal function in which one kidney received intrarenal infusion of ADM (1 ng ⋅ kg−1⋅ min−1) while the contralateral kidney served as control before and during the systemic infusion of a NEP inhibitor (Candoxatrilat, 8 μg ⋅ kg−1⋅ min−1; Pfizer). In response to ADM, glomerular filtration rate (GFR) in the ADM kidney did not change, whereas renal blood flow, urine flow (UV), and urinary sodium excretion (UNaV) increased from baseline. Proximal and distal fractional reabsorption of sodium decreased in the ADM-infused kidney. In response to systemic NEP inhibition, UNaV and UV increased further in the ADM kidney. Indeed, ΔUNaV and ΔUV were markedly greater in the ADM kidney compared with the control kidney. Plasma ADM was unchanged during ADM infusion but increased during NEP inhibition. In conclusion, the present investigation is the first to demonstrate that NEP inhibition potentiates the natriuretic and diuretic responses to intrarenal ADM. This potentiation occurs secondary to a decrease in tubular sodium reabsorption. Lastly, the increase in plasma ADM during systemic NEP inhibition supports the conclusion that ADM is a substrate for NEP.